8
Setting the Functions
When you press the
PROG
program button for 6
seconds, you are taken to a menu where various
basic functions can be set. The functions are
shown on the left-hand side of the display and
the corresponding value or status on the right.
When you press the
SET
program button, you are taken to the desired set-
ting option. The setting option blinks on the display.
By pressing the
+
or
–
program buttons, the value of the selected setting op-
tions can be changed and your selection confirmed by pressing the
SET
button.
After confirming the last function, the unit returns to the operating mode from
which the
“
Setting the Functions
”
menu was accessed.
The individual parameters mean the following:
Setting the Control Parameters
When you press the
PROG
program button for 6
seconds, you are taken to a menu where various
basic functions can be set. The functions are
shown on the left-hand side of the display and
the corresponding value or status on the right.
When you press the
SET
program button, you are taken to the desired set-
ting option. The setting option blinks on the display.
By pressing the
+
or
–
program buttons, the value of the selected setting op-
tions can be changed and your selection confirmed by pressing the
SET
button.
After confirming the last function, the unit returns to the operating mode from
which the
“
Setting the Control Parameters
”
menu was accessed.
The individual parameters mean the following:
When used as a two-point control mechanism:
Parameter
Default setting Minimum value Maximum value
Activation difference
± 1.0 K
± 0.1 K
± 3.0 K
Per proportional control
± 3.0K
± 1.0 K
± 10.0 K
Pulse width
5 min
1 min
15 min
When used as a pulsating control mechanism: