Entering a Timer Program

 

Programming example:

  

Change P02 to:  MO - SA, starting at 18:30; night operation; (P02)

 

 

Display 

Button  Explanation 

1. 

 

PROG  Set timer program (change) 

2.  22:00 P01 

+/- 

Program selection P01 blinking; change setting with [+] 

3.  22:00 P02 

SET 

Confirm entry 

4. 

22:00 

+/- 

Time setting blinking; change setting with [-]  

5. 

18:30 

SET 

Confirm entry 

6. 

'  '  '  '  ' 

+/- 

Days of the week blinking; change setting with [+]  

7. 

'  '  '  '  ' 

SET 

Confirm entry 

8. 

   

ƒ

 

SET 

Arrow blinking next to night operation; keep setting 

9. 

P02 

PROG  P02 blinking; end programming with [PROG] 

The timer program can be entered after the 

PROG 

program button was pressed briefly. The program 
point number appears on the display (PO1 to P16), 
the corresponding time and day of the week on 
which the respective temperature mode (

Comfort 

temperature

 or 

Cooling temperature

; sea indicator on the right) will go into 

effect. 
When you press the 

SET 

program button, you are taken to the desired set-

ting option (

Program point number

 -> 

Time

 -> 

Day 

-> 

Temperature mode

).  

Each selected setting option blinks on the display. 
By pressing the 

+

 or 

– 

program buttons, the value of the selected option can 

be changed and your selection confirmed by pressing the 

SET

 button. 

If you press the 

PROG 

program button while the program point number is 

blinking, the unit returns to the operating mode from which the 

“Enter Time 

Program” 

menu was accessed.  

Inactive program points are identified by a 

- -:- - 

instead of the time. 

The following are standard presets made at the factory: 
           Mo – So:        starting at 06:00 o’clock                 Comfort temperature 
           Mo – Fr:         starting at  22:00 o’clock                Cooling temperature 
           Sa – So:        starting at 23:00 o’clock                 Cooling temperature 

There are several options for setting the days of the week: 
           Individual days                                Different activation times 
           Monday - Friday                              Same activation times 
           Monday - Saturday                         Same activation times 
           Monday - Sunday                           Same activation times 
           Saturday - Sunday                          Same activation times

 

Содержание ATR-4

Страница 1: ...REMKO ATR 4 Electronic Clock Thermostat Edition GB H12 Operation Technology Original REMKO REMKO powerful like a bear...

Страница 2: ......

Страница 3: ...are made to the supplied unit Electronic Clock Thermostat REMKO ATR 4 Important Always keep these operating instructions near or on the unit Contents Page Functionality 4 Operating Controls 4 Comfort...

Страница 4: ...left hand side of the display shows the operating mode Comfort Temperature The desired comfort temperature 5 to 40 C is set on the upper rotating knob 2 It is displayed on the right hand side of the...

Страница 5: ...ed on the right hand side of the display The unit continues to record the current temperature but all control functions are completely switched off Hand Button The button makes it possible to change t...

Страница 6: ...again Selecting the Operating Mode The main operating modes are selected by pressing one of the three program buttons on the left You can select from the following modes Automatic Comfort continuous...

Страница 7: ...fect When you press the SET program button you are taken to the desired set ting option Program point number Time Day Temperature mode Each selected setting option blinks on the display By pressing th...

Страница 8: ...you press the PROG program button for 6 seconds you are taken to a menu where various basic functions can be set The functions are shown on the left hand side of the display and the corresponding val...

Страница 9: ...eating Co cooling 2PPu 2 point Pulsating function display When the control function is switched from 2 point to pulse and vice versa this results in the corresponding parameters being calculated on th...

Страница 10: ...nductors from becoming loose that meets the requirements of EN 60730 Part 1 This can be achieved for example by securing the lines with cable bindings Compliance with VDE 0100 EN 60730 Part 1 as well...

Страница 11: ...of the housing If the entire panel is removed it is possible that the housing no longer com pletely closes M O DI M I DO F R SASO M O DI M I DO F R SASO G Note The electronic clock thermostat must be...

Страница 12: ...REMKO heater is made at terminals 1 and 3 For cooling units to terminals 1 and 2 G Caution There must be a power current of 230 V 50 Hz at terminals 6 and 7 at all times for the unit to function We re...

Страница 13: ...P15 P16 The following tables can be used to enter individual customer data Customer Data Timer program Control parameters Activation difference or Proportional control Pulse duration Functions Sensor...

Страница 14: ...timer Power reserve 1 approx 15 minutes Display LC display Operating current 230 V AC 10 Power consumption approx 2VA Relay contact 1 isolated change over contact Max supply of switch current 10 4 A 2...