background image

NEVER LEAVE HEATER UNATTENDED WHILE BURNING, 

CONNECTED TO A POWER SOURCE, OR WHILE 

CONNECTED TO A FUEL SOURCE

© 2015, Pinnacle Products International, Inc. 

Convection Heater User's Manual

Operation

Pre-Lighting Instructions:

Connecting the LP Cylinder

ALL NEW LP CYLINDERS MUST BE PURGED 

BEFORE THE FIRST FILLING.

 

Turn heater gas valve knob and LP cylinder 

valve to OFF position.

 

LP cylinder valve equipped with old style 

fitting has LEFT HANDED THREADS. Turn 

fitting CLOCKWISE to loosen. Protect this 

fitting when disconnected from LP cylinder.

 

Have your LP cylinder filled by your local 

propane gas supplier.

 

Some LP cylinders have a bleed-OFF valve. 

This valve should be inspected for leaks after 

each filling of the LP cylinder. Turn the valve 

clockwise to close.

 

Fasten full propane tank and connect 

proper fitting to LP cylinder valve by turning 

COUNTER-CLOCKWISE.

 

With heater gas valve knob still in OFF 

position turn ON the LP cylinder valve and 

check for leaks with soap solution.

Checking For Leaks

 

To check for leaks, make up a 50/50 solution 

of dish soap and water. Apply this solution 

to all gas connections. If bubbles appear, 

there is a leak. If a leak is found, turn off 

the gas supply, and re-connect the leaking 

connection. If the leak persists after several 

tries, contact Pinnacle Customer Service at 

(800)-641-6996.

 

The installation of this heater must meet all 

local codes and/or gas utility requirements. In 

the absence of local codes, the National Fuel 

Code ANSI Z223.1 should be followed.

 

The minimum clearances to any combustible 

construction materials must be maintained at 

all times (See Page 2).

 

Inspect the heater before each use, and at 

least annually by a qualified service person.

Purging and filling of the 

LP cylinders must be 

performed by personnel who have been 

thoroughly trained in accepted LP gas 

industry procedures. Failure to follow these 

instructions may result in explosion, fire, 

severe personal injury or death. 

WARNING

Supply Valve

Regulator

Hose

Propane Tank

 Figure 6

7

Содержание HH-18-PCH-A

Страница 1: ...SONING AND OR ELECTRIC SHOCK ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE OR SERVICE THIS HEATER IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUCTIONS MANUAL L...

Страница 2: ...sed areas DANGER Not for use in residential living areas or in non adequately ventilated enclosed spaces Never bring or store a propane cylinder indoors DANGER If the information in this manual is not...

Страница 3: ...USE PERMITTED ONLY FOR The temporary heating of adequately ventilated buildings or structures under construction alteration or repair Provide at least a three square foot 2 800 sq cm opening of outsi...

Страница 4: ...ed with this heater Inspect the regulator hose assembly prior to each use of the heater If there is excessive abrasion or wear or if the hose is cut replace it with the proper assembly shown in the pa...

Страница 5: ...rnational Inc Convection Heater User s Manual Features HH 18 PCH A Specifications Model HH 18 PCH A BTU 6 600 12 000 18 000 Fuel Consumption Lbs hr 0 31 0 56 0 83 Heat Settings 3 Maximum Operating Hou...

Страница 6: ...propane LP cylinder that has a connection device that is compatible with the hose and regulator assembly supplied Remove the back cover by sliding the cover straight up and away from the heater body P...

Страница 7: ...e at the LP Cylinder immediately The Propane LP cylinder must also be equipped with the following A collar to protect the gas valve A shut off valve terminating a LP cylinder valve outlet as specified...

Страница 8: ...OFF position turn ON the LP cylinder valve and check for leaks with soap solution Checking For Leaks To check for leaks make up a 50 50 solution of dish soap and water Apply this solution to all gas...

Страница 9: ...the valve knob 7 If heater fails to light or does not stay lit repeat steps 2 through 6 8 When the center burner panel stays lit turn the valve knob to the desired setting Shut Down Instructions 1 Tur...

Страница 10: ...dance with the Standard for Storage and Handling of Liquefied Gasses ANSI NFPA 58 latest edition The plastic valve plug or valve cover supplied with the LP cylinder must be reinstalled on the valve to...

Страница 11: ...d when ignited 1 Incorrect igniter electrode position 2 Electrode damaged or broken 3 Loose or disconnected igniter wire 4 Broken igniter wire 1 Properly position electrode 2 Replace the electrode 3 T...

Страница 12: ...Front Panel 50 001 0170 21 Burner Assembly 50 005 0105 6 Heat Plate 50 002 0205 22 Reflector 50 003 0210 7 Inlet Connector 50 019 0110 23 Wind Cover A 50 018 0110 8 Manual Valve Assembly 50 013 0160 2...

Страница 13: ...ernational Inc finds the item to be in normal operating condition or not defective the item will be returned freight collect This Limited Warranty is in lieu of all other express warranties Pinnacle P...

Страница 14: ..._____ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ___________...

Страница 15: ..._______ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ _________...

Страница 16: ...2015 Pinnacle Products International Inc 668 Stony Hill Road 302 Yardley PA 19067 USA Toll Free 800 641 6996 Fax 215 891 8461 Web www pinnacleint com Email info pinnacleint com...

Отзывы: