background image

NEVER LEAVE HEATER UNATTENDED WHILE BURNING, 

CONNECTED TO A POWER SOURCE, OR WHILE 

CONNECTED TO A FUEL SOURCE

© 2015, Pinnacle Products International, Inc. 

Convection Heater User's Manual

Unpacking and Assembly

- Remove heater and base from carton (save 

  carton and packing materials for later storage)

- Remove all protective packaging protecting 

  heater during shipping.

- Place heater base on flat surface with wheels 

  on ground.

- Line up holes in bottom of heater cabinet with 

  locking tabs on top of base (see figure 2)

- Mount heater cabinet to heater base, sliding 

  tabs through holes in bottom of cabinet and 

  sliding cabinet backward approximately 1/4" or

  until cabinet will not move further back.

- Use thumbscrews to attach heater cabinet to 

  heater base.

- Inspect heater closely for any damage that may

  have occured during shipping. If there is any 

  damage, return the heater to place of purchase.

Connecting to Gas Supply

IMPORTANT! - Always use a propane (LP) 

cylinder that has a connection device that is 

compatible with the hose and regulator assembly 

supplied.

- Remove the back cover by sliding the cover 

  straight up and away from the heater body. 

  Place the LP cylinder on the bottom plate and 

  replace the back cover.

- To connect LP cylinder, insert regulator end 

  fitting into cylinder valve, rotate coupling nut 

  clockwise and tighten firmly (see figure 3)

- Open valve on propane cylinder slowly. If the 

  valve is not opened slowly, the excess flow 

  check valve in the regulator will stop the flow of

  gas. If this should happen, close the valve, wait

  one minute (or until you hear the valve click), 

  and re-open, slowly.

- Be sure to inspect all connections for leaks, by 

  using a 50/50 mixture of dish soap and water on

  all connection. Any bubbles forming indicate a 

  leak.

Missing Parts? Please Call 800-641-6996 For Assistance

5

The Propane (LP) gas 

pressure regulator and hose 

assembly supplied with the heater must be 

used without alteration.

CAUTION

Be sure to inspect the 

regulator hose before each 

use. If the hose is cut or frayed, replace it 

with the manufacturer suggested assembly.

CAUTION

Содержание HH-18-PCH-A

Страница 1: ...SONING AND OR ELECTRIC SHOCK ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE OR SERVICE THIS HEATER IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUCTIONS MANUAL L...

Страница 2: ...sed areas DANGER Not for use in residential living areas or in non adequately ventilated enclosed spaces Never bring or store a propane cylinder indoors DANGER If the information in this manual is not...

Страница 3: ...USE PERMITTED ONLY FOR The temporary heating of adequately ventilated buildings or structures under construction alteration or repair Provide at least a three square foot 2 800 sq cm opening of outsi...

Страница 4: ...ed with this heater Inspect the regulator hose assembly prior to each use of the heater If there is excessive abrasion or wear or if the hose is cut replace it with the proper assembly shown in the pa...

Страница 5: ...rnational Inc Convection Heater User s Manual Features HH 18 PCH A Specifications Model HH 18 PCH A BTU 6 600 12 000 18 000 Fuel Consumption Lbs hr 0 31 0 56 0 83 Heat Settings 3 Maximum Operating Hou...

Страница 6: ...propane LP cylinder that has a connection device that is compatible with the hose and regulator assembly supplied Remove the back cover by sliding the cover straight up and away from the heater body P...

Страница 7: ...e at the LP Cylinder immediately The Propane LP cylinder must also be equipped with the following A collar to protect the gas valve A shut off valve terminating a LP cylinder valve outlet as specified...

Страница 8: ...OFF position turn ON the LP cylinder valve and check for leaks with soap solution Checking For Leaks To check for leaks make up a 50 50 solution of dish soap and water Apply this solution to all gas...

Страница 9: ...the valve knob 7 If heater fails to light or does not stay lit repeat steps 2 through 6 8 When the center burner panel stays lit turn the valve knob to the desired setting Shut Down Instructions 1 Tur...

Страница 10: ...dance with the Standard for Storage and Handling of Liquefied Gasses ANSI NFPA 58 latest edition The plastic valve plug or valve cover supplied with the LP cylinder must be reinstalled on the valve to...

Страница 11: ...d when ignited 1 Incorrect igniter electrode position 2 Electrode damaged or broken 3 Loose or disconnected igniter wire 4 Broken igniter wire 1 Properly position electrode 2 Replace the electrode 3 T...

Страница 12: ...Front Panel 50 001 0170 21 Burner Assembly 50 005 0105 6 Heat Plate 50 002 0205 22 Reflector 50 003 0210 7 Inlet Connector 50 019 0110 23 Wind Cover A 50 018 0110 8 Manual Valve Assembly 50 013 0160 2...

Страница 13: ...ernational Inc finds the item to be in normal operating condition or not defective the item will be returned freight collect This Limited Warranty is in lieu of all other express warranties Pinnacle P...

Страница 14: ..._____ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ___________...

Страница 15: ..._______ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ _________...

Страница 16: ...2015 Pinnacle Products International Inc 668 Stony Hill Road 302 Yardley PA 19067 USA Toll Free 800 641 6996 Fax 215 891 8461 Web www pinnacleint com Email info pinnacleint com...

Отзывы: