2. Shut off the gas supply.
3. Keep the installation frost-free.
Do not shut-down the boiler if the installation can't be kept frost-free.
11.14 Frost protection
Caution
Drain the boiler and central heating system if you are not going
to use your home or the building for a long time and there is a
chance of frost.
The frost protection does not work if the boiler is out of
operation.
The built-in boiler protection is only activated for the boiler and
not for the system and radiators.
Open the valves of all the radiators connected to the system.
Set the temperature control low, for example to 10°C.
If the temperature of the central heating water in the boiler drops too low,
the built-in boiler protection system is activated. This system works as
follows:
If the water temperature is lower than 7°C, the pump switches on.
If the water temperature is lower than 4°C, the boiler switches on.
If the water temperature is higher than 10℃, the burner shuts down and
the pump continues to run for a short time.
To prevent the system and radiators freezing in frost-sensitive areas (e.g.
a garage), a frost thermostat or, if feasible, an outdoor sensor can be
connected to the boiler.
11.15 Cleaning the casing
1. Clean the outside of the appliance using a damp cloth and a mild
detergent.
12 Technical specifications
12.1 Homologations
12.1.1 Certifications
Tab.58 Certifications
CE identification number
PIN 0063CQ3781
Class NOx
6
Type of flue gas connection
B
23P
C
13
, C
33
, C
53
(1) EN 15502–1
(2) When installing a boiler with connection type B
23P
, the IP rating of the boiler is lowered to IP20.
12.1.2 Unit categories
Tab.59 Unit categories
Country
Gas type
Connection pressure (mbar)
Great Britain
II
2H3B/P
G20 (H gas)
G30/G31 (butane/propane)
20
30-50
(1) This appliance is suitable for category I
2H
containing up to 20% Hydrogen gas (H
2
).
12 Technical specifications
7701838 - v.09 - 10122021
67