CAUTION
4
Ensure that there is no dust in the gas pipe. Blow into
the pipe or shake it before mounting.
4
We recommend installing a gas filter on the gas pipe
to prevent clogging of the gas valve unit.
4
Connect the gas pipe in accordance with prevailing
standards and regulations.
5.7
Flue gas system connections
DANGER
Ensure that the flue gas pipes are held firmly in place in
order to prevent any dislocation.
5.7.1.
Classification
4
1
2
4
3
6
2
2
8
9
4
C33(x)
C93(x)
C93(x)
B23P
C53
B23P
B33
1
B33
C33(x)
C33(x)
C13(x)
5
7
C43(x)
C83(x)
5
7
C43(x)
C83(x)
5
7
C43(x)
C83(x)
C003087-C
1
Configuration B
33
Connection to a collective pipe via a concentric pipe
(combustive air taken from the boiler room)
All of the pressurised parts of the appliance are
surrounded by air.
2
Configuration B
23
- B
23P
Connection to a chimney using a connection kit
(combustive air taken from the boiler room)
3
Configuration C
13(x)
Air/flue gas connection by means of concentric pipes to a
horizontal terminal (so-called forced flue)
4
Configuration C
33(x)
Air/flue gas connection by means of concentric pipes to a
vertical terminal (roof outlet)
5. Installation
CALORA TOWER GAS 15S EX CALORA TOWER GAS 25S EX
CALORA TOWER GAS 35S EX
32
22/04/2016 - 300026141-001-07