General Information

 

 
The remote control of the T7 2G4 series is designed to meet specific 
user  requirements,  first  among  them  the  ability  to  work  on  lifting 
machines, such as cranes, defining the operational area. 
For this function Remdevice filed 

Utility Patent

The use of radio frequencies in the 2.4 GHz band with high directivity 
and  the  special  panel  antenna,  appropriately  installed  in  the 
overhead  crane  above  the  work  area,  allows  to  limit  the  operating 
distance  where  the  operator  can  move  safely  and  preventing, 
therefore, its use over this distance. 
This system, besides the advantage of ensuring that the operator is 
located in the immediate vicinity of the machine for its use, has the 
additional  advantage  of  being  immune  to  interference  from  other 
transmitters  installed  on  machines  in  the  vicinity,  avoiding  the  very 
common  problems    in  industrials  sites  where  the  installer  has 
increasing  difficulty  in  arrange  the  coexistence  of  the  many  existing 
radio equipment. 

 

Working 

Area 

Not 

Working 

Area 

antenna 

model 

Rx2G4 

receiving 

direction 

white 

plastic 

cover 

metal 

plate 

IMPORTANT 

the antenna model Rx2G4 it’s a 

directional antenna

 

 

it  must  be  positioned  oriented 

to the operator (Working Area)  

 

avoid  metal  objects  between 

the  Rx2G4  antenna  and  the 
operator (Working Area) 

 

Instruction Manual  
Radio control devices T3, T5 and T7 @ 

2G4

 

version 1.3 January 14

 

page 4 of 28 

REM

device

®

- ITALY

 

INSTRUCTIONS  FOR  CORRECT  AND  SAFE 
USE OF THE RADIO CONTROL DEVICE 

 

The 

use

  of  the  radio  control  device  is  reserved  to  expert  operators 

who have read the instructions on the conditions of use of the radio 
controlled  machine  and  who  respect  the  safety  regulations  imposed 
by law in the work area. 

 
 

The  manufacturer  of  the  radio  control  device  does  not  answer  for 
damage to persons or things caused by: 

 

clumsy and improper use of the radio control device; 

 

incorrect wiring or electrical connection; 

 

tampering; 

 

modification  of  the  structural  characteristics  of  the  radio 
control device; 

 

replacement of parts with non original spare parts; 

 

lack of maintenance; 

 

failure to replace worn, broken or faulty parts; 

 

use  of  the  radio  control  device  bypassing  its  intrinsic  safety 
or in any way altering its original functionality. 

 

The  radio  control  device  operates  with  radio  signals,  it  is  able  to 
operate the machine to which it is connected even in the presence of 
barriers  that  prevent  visibility,  such  as:  masonry  walls,  metal  or 
wooden panels, machines, equipment, buildings, vehicles, etc. 

 

Use of the radio control device  

 

Place  the  transmitter  in  conditions  of  perfect  and  complete 
visibility of the radio-controlled machine; 

 

do not stand under hanging weights; 

 

do not operate in a position of unsafe equilibrium; 

 

pay  attention  to  the  identification  symbols  of  the  control 
device located next to each button; 

 

avoid  pressing  the  buttons  if  you  do  not  know  exactly  what 
their function is. 

 

 

 
 

 

Содержание T3 @ 2G4

Страница 1: ...or correct and safe use of the radio control device 4 Installation of the radio control device 8 Arrangement and description of controls 10 Inspection of the radio control device 15 Keeping the radio control device in good working order 16 Changing the battery 17 Changing the transmitter 18 Programming the radio control device 19 Conformity 20 Diagnostics 23 Operating principle 24 Identification o...

Страница 2: ...g Area Instruction Manual Radio control devices T3 T5 and T7 2G4 version 1 3 January 14 page 4 of 28 REMdevice ITALY INSTRUCTIONS FOR CORRECT AND SAFE USE OF THE RADIO CONTROL DEVICE The use of the radio control device is reserved to expert operators who have read the instructions on the conditions of use of the radio controlled machine and who respect the safety regulations imposed by law in the ...

Страница 3: ...the radio control device Press the control buttons for the desired function taking care as they may be of the type with a sequential double click by increasing the pressure on the button a second contact is made that is normally assigned to increasing the speed of a machine movement If any kind of difficulty occurs in controlling the operating machine for mechanical or electrical reasons or at any...

Страница 4: ...about 2000 hours continuous duty 1 2 3 4 5 6 7 S Figure 2 Instruction Manual Radio control devices T3 T5 and T7 2G4 version 1 3 January 14 page 8 of 28 REMdevice ITALY INSTALLATION OF THE RADIO CONTROL DEVICE REMdevice is at the disposal of installation technicians to supply useful information that will ensure the correct installation and commissioning of the radio control device Training of perso...

Страница 5: ...ment requires it it is necessary to provide protective measures to prevent reduce and report situations of potential danger Must be considered that The remote control T7 is not suitable for installation in environments requiring explosion proof equipment machines for handling lifting and transportation of people or machines that could lead to dangerous situations in the event of shutdown due to lo...

Страница 6: ...rea The measurements for drilling the holes for Ruby terminal are indicated in Figure 4 Never make a hole in the box Avoid precarious fixing systems For correct and safe wiring of the Terminal use a multicore cable and plug of the same type as those used for the wired pushbutton panel supplied with the machine Use caps to terminate the leads to be tightened to the receiver terminals and check the ...

Страница 7: ...l devices T3 T5 and T7 2G4 version 1 3 January 14 page 14 of 28 REMdevice ITALY Arrangement of controls in the receiver RBT T7 0V 24 48V 115V 230V Receiver power supply STOP Stop Emergency Contact N C with transmitter active START Start Contact N O CLAX Horn Contact N O it closes with the START command LAMP Contact for flashing light N C with transmitter active ABIL Enabling Contact N O it closes ...

Страница 8: ...e movements give the various commands in the different zones of the work area to ensure that it is fully covered by the radio signal At the end of inspection clearly fill in the wiring diagram of the receiver and sign the declaration of correct installation The serial number of the radio control device to be given on the documentation is indicated on the Receiver fig 4 and is not on the Transmitte...

Страница 9: ...and T7 2G4 version 1 3 January 14 page 18 of 28 REMdevice ITALY CHANGING THE TRANSMITTER In the event of malfunction breakage or loss of the transmitter it is possible to replace it with a new one The programming of the code involves only the transmitter while the receiver is combined and tuned automatically thanks to the exclusive new patented REMSYS CODE System For this reason the serial number ...

Страница 10: ...1 2 3 4 5 6 7 S RED LED TENS GREEN LED UNITS Figure 10 Instruction Manual Radio control devices T3 T5 and T7 2G4 version 1 3 January 14 page 20 of 28 REMdevice ITALY Tables of frequencies Band 2 4 GHz CH6 2 41075 CH7 2 41275 CH8 2 41475 CH9 2 41675 CH10 2 41875 CH11 2 42075 CH12 2 42275 CH13 2 42475 CH14 2 42675 CH15 2 42875 CH16 2 43075 CH17 2 43275 CH18 2 43475 CH19 2 43675 CH20 2 43875 CH21 2 4...

Страница 11: ... Button 7 EXCLUDED Button 7 ACTIVE Button 7 ACTIVE Relay A Relay A B with CR1 or CR3 Button 4 AUXILIARY BUTTON Button 7 ACTIVE Relay CR13 Pulse Button 7 ACTIVE Relay CR13 Step by step Button 7 ACTIVE Relay A Relay B Relay A B Button 5 1 2 3 4 5 6 7 S RED LED GREEN LED Figure 11 Instruction Manual Radio control devices T3 T5 and T7 2G4 version 1 3 January 14 page 22 of 28 REMdevice ITALY Change of ...

Страница 12: ...the led PWR lit Has frequency been changed Check STOP fuse Does the machine start Are all manoeuvres working Machine working Have you checked STOP fuse NO YES NO YES YES NO YES NO YES YES NO NO NO YES YES NO Is the red led blinking START UP at low power approach the machine NO YES Figure 13 Instruction Manual Radio control devices T3 T5 and T7 2G4 version 1 3 January 14 page 24 of 28 REMdevice ITA...

Страница 13: ...10 8 less than 1 in 100 000 000 24 bits are used for the control code 8 bits are used for setup The 48 address bits are used to couple the transmitter to the receiver with a code which is set by the manufacturer and assigned univocally to each radio control device produced using the new and exclusive REMSYS CODE system Instruction Manual Radio control devices T3 T5 and T7 2G4 version 1 3 January 1...

Страница 14: ...Y GUARANTEE CONDITIONS REMdevice guarantees the radio control device for 12 months The starting date of the guarantee period is that of the transport document The guarantee is valid only for appliances that present manufacturing defects The radio control device MUST NOT have undergone attempted repairs tampering or replacement of parts by personnel not authorised by REMdevice The guarantee is void...