11
Picture 7 Picture 8
Frame Installation
Take the frame from the bag, and then plug the cable into bracket from the top of
the bracket. Next, install the G1 1/2 screw on the top of the outer cover into the screw
holes of wall-mounted bracket, and fasten it with 2 bolts (M8).
Outer Wire Connection
Connect the BNC video interface of Dome Camera to the arranged video cable;
connect the power cord to the arranged power cord (AC12V/ AC24V). RS485 control
wire is connected to RS485 control wire layer out.
◆
Ensure that the positive and negative polarity of RS485 is properly
connected. “A” represents positive pole, while “B” negative pole.
If RS485 is wrongly connected, it could not control the Dome Camera.
a. Check the polarity of the plug and socket, and the connection of cable, then
power on.
b. When the self-checking starts, the Dome will turn 360°horizontally and then
90° vertically for the testing of the camera and the electrical and mechanical structure
of the Dome, and turn back to the initial position by the resetting program, then
vertically turn to 45
°
.When the Dome totally stops, the self-checking finishes and it
is ready to be under control.