RPV516/RPU416 Adjustment Description
- 16 -
Adjust the transmitter section:
Measurement
Adjustment
Item
Condition
Test
equipment
Terminal
Parts
Method
Specifications
/Remarks
8.Transmit
frequency
CH: TX Center
Turn to channel
1 in manual
mode.
Communication
analyzer
ANT VR1
Adjust it to center
frequency
Error<150Hz
1.CH:TX Center
Turn to channel
2 in manual
mode.
Communication
analyzer
Ammeter
ANT
PTT
(upwards)
MONI
(downwards)
Adjust it to:
4.0 W
≤
Po
≤
4.8W
(RPV516)
3.7 W
≤
Po
≤
4.7W
(RPU416)
I
≤
1.6A
2.CH: TX Low
Turn to channel 3
Press PTT
Adjust it to:
4.0 W
≤
Po
≤
4.8 W
(RPV516)
3.7 W
≤
Po
≤
4.7 W
(RPU416)
I
≤
1.6A
9. Power
3.CH:TX High
Turn to channel 4
Press PTT
Adjust it to:
4.0 W
≤
Po
≤
4.8 W
(RPV516)
3.7 W
≤
Po
≤
4.7 W
(RPU416)
I
≤
1.6A
1. CH: TX Center
Turn to channel
13 in manual
mode. Channel
spacing: wide
Press PTT
VR501
Adjust deviation to:
4.2KHz±100Hz
Wide
10. Max.
Deviation
2. CH: TX Center
Turn to channel
13 in manual
mode. Channel
spacing: narrow
Press PTT
Communication
analyzer
LPF:15KHz
AF:1KHz
120mV
ANT
MIC
Check:
1.8KHz-2.2KHz
Narrow
1. CH: TX Center
Turn to channel
13 in manual
mode. Channel
spacing: wide
Press PTT
VR501
Check:
2.2KHz-3.6KHz
Wide
11.MICSENS
2. CH: TX Center
Turn to channel
13 in manual
mode.
Channel spacing:
narrow
Press PTT
Communication
analyzer
FILTER:
0.3-3.4KHz
AF:1KHz
+12mV
ANT
MIC
Check:
1.1KHz-1.8KHz
Narrow
Содержание RPU416
Страница 2: ......