5

Reliant_Back Bar_User Manual_Jan19

SEALING CABINET TO FLOOR

Step 1 – Position Cabinet:

 Allow a minimum of four inches between the wall and rear of the refrigerated bar 

equipment to assure proper ventilation.

Step 2 – Level Cabinet:

 Cabinet should be level side-to-side and front-to-back. Place a carpenter’s level in the 

interior cabinet floor in four places:

 

- Position level in the inside floor of the unit near the doors, parallel to cabinet front. Level cabinet.

 

- Position level at the inside rear of cabinet, parallel to cabinet back. Level cabinet.

 

- Perform similar procedures to steps A & B by placing the level on inside floor (left and right sides — parallel to 

the depth of the cooler). Level cabinet.

Step 3 – Applying Sealant:

•  Draw an outline on the base of the floor.
•  Raise and block the front side of the cabinet.
•  Apply a bead of NSF Approved Sealant (see list below) to floor half an inch inside the outline drawn. The bead 

must be heavy enough to seal the entire cabinet surface when it set down on the sealant.

•  Raise and block the rear of the cabinet.
•  Apply sealant on floor as outlined above on other 3 sides.
•  Examine to see that the cabinet is sealed to floor around entire perimeter.

NSF APPROVED SEALANTS:

•  Minnesota Mining #ECU800 Caulk
•  Minnesota Mining #ECU2185 Caulk
•  Minnesota Mining #ECU1055 Bead
•  Minnesota Mining #ECU1202 Bead

•  Armstrong Cork -Rubber Caulk
•  Products Research Co #5000 Rubber Caulk
•  GE Silicone Sealer
•  Dow Corning Silicone Sealer

NOTE: 

Asphalt floors are very susceptible to chemical attack. A layer of tape on the floor prior to applying the 

sealant will protect the floor.

START UP

Plug in the cooler and the compressor is ready to operate.
•  Temperature control set at #4 position gives the cooler an approximate temperature of 35°F. Allow unit to 

function several hours, completely cooling cabinet before changing the control setting.

•  Excessive tampering with the control could lead to service difficulties. Should it ever become necessary to 

replace the temperature control it should be ordered from your dealer or recommended service agent.

•  Good air flow in your cooler is critical. Be careful to load product so that it neither presses against the back wall 

nor comes within four (4) inches of the evaporator housing. Refrigerated air off the coil must circulate down the 
back wall.

NOTE: 

If the unit is disconnected or shut off, wait five (5) minutes before re-starting unit.

LIGHT SWITCH LOCATION:

The switch is located on the front of the evaporator housing toward the right of the cabinet.

RECOMMENDATION

Before loading product the unit should be run for 2 to 3 days. This allows confirmation that the electrical wiring 
and installation are correct and no shipping damage has occurred. Remember that the factory warranty does not 
cover product loss.

REPLACEMENT PARTS

We maintain a record of the cabinet model number and serial number for your cooler. If at any time during the life 
of your cooler a replacement part is needed, call your dealer with the model number and serial number of your 
unit to place an order for the part.

Содержание RXBB-2472

Страница 1: ...asp by the plug not by the cord If the voltage is unstable please use a suitable automatic voltage regulator If the power cuts off you should wait for at least 5 minutes before turning on the unit aga...

Страница 2: ...ire or explosion Dispose of properly in accordance with federal or local regulations Flammable refrigerant used DANGER Risk of fire or explosion due to puncture of refrigerant tubing follow handling i...

Страница 3: ...3 Reliant_Back Bar_User Manual_Jan19 BEER DISPENSING SYSTEM DRAFT BEER TOWER INSTALLATION...

Страница 4: ...grounding wall outlet to minimize the possibility of electric shock hazard If the outlet is a standard 2 prong outlet it must be replaced with the properly grounded wall outlet NEVER USE AN ADAPTOR P...

Страница 5: ...rning Silicone Sealer NOTE Asphalt floors are very susceptible to chemical attack A layer of tape on the floor prior to applying the sealant will protect the floor START UP Plug in the cooler and the...

Страница 6: ...flow to the coil which is similar to having a dirty coil KEG BEER LINE CLEANING 1 Tools 2 Pour cleaning solution and water into pump bottle and connect it to the beer line 3 Place a bucket under fauce...

Страница 7: ...are the worst type of chlorides to use EIGHT STEPS THAT CAN HELP PREVENT RUST ON STAINLESS STEEL 1 Use the correct cleaning tools Use non abrasive tools when cleaning your stainless steel products Th...

Страница 8: ...pletely Remove gasket and wash with soap and water Check condition of gasket and replace if necessary Dirty condenser coil Clean the condenser coil Evaporator coil iced over Unplug unit and allow coil...