SEALING CABINET TO FLOOR
Step 1 – Position Cabinet:
Allow a minimum of four inches between the wall and rear of the refrigerated bar
equipment to assure proper ventilation.
Step 2 – Level Cabinet:
Cabinet should be level side-to-side and front-to-back. Place a carpenter’s level in the
interior cabinet floor in four places:
- Position level in the inside floor of the unit near the doors, parallel to cabinet front. Level cabinet.
- Position level at the inside rear of cabinet, parallel to cabinet back. Level cabinet.
- Perform similar procedures to steps A & B by placing the level on inside floor (left and right sides — parallel to
the depth of the cooler). Level cabinet.
Step 3 – Applying Sealant:
• Draw an outline on the base of the floor.
• Raise and block the front side of the cabinet.
• Apply a bead of NSF Approved Sealant (see list below) to floor half an inch inside the outline drawn. The bead
must be heavy enough to seal the entire cabinet surface when it set down on the sealant.
• Raise and block the rear of the cabinet.
• Apply sealant on floor as outlined above on other 3 sides.
• Examine to see that the cabinet is sealed to floor around entire perimeter.
NSF APPROVED SEALANTS:
• Minnesota Mining #ECU800 Caulk
• Minnesota Mining #ECU2185 Caulk
• Minnesota Mining #ECU1055 Bead
• Minnesota Mining #ECU1202 Bead
• Armstrong Cork -Rubber Caulk
• Products Research Co #5000 Rubber Caulk
• GE Silicone Sealer
• Dow Corning Silicone Sealer
NOTE:
Asphalt floors are very susceptible to chemical attack. A layer of tape on the floor prior to applying the
sealant will protect the floor.
START UP
Plug in the cooler and the compressor is ready to operate.
• Temperature control set at #4 position gives the cooler an approximate temperature of 35°F. Allow unit to
function several hours, completely cooling cabinet before changing the control setting.
• Excessive tampering with the control could lead to service difficulties. Should it ever become necessary to
replace the temperature control it should be ordered from your dealer or recommended service agent.
• Good air flow in your cooler is critical. Be careful to load product so that it neither presses against the back wall
nor comes within four (4) inches of the evaporator housing. Refrigerated air off the coil must circulate down the
back wall.
NOTE:
If the unit is disconnected or shut off, wait five (5) minutes before re-starting unit.
LIGHT SWITCH LOCATION:
The switch is located on the front of the evaporator housing toward the right of the cabinet.
RECOMMENDATION
Before loading product the unit should be run for 2 to 3 days. This allows confirmation that the electrical wiring
and installation are correct and no shipping damage has occurred. Remember that the factory warranty does not
cover product loss.
REPLACEMENT PARTS
We maintain a record of the cabinet model number and serial number for your cooler. If at any time during the life
of your cooler a replacement part is needed, call your dealer with the model number and serial number of your
unit to place an order for the part.