2. Disassembly of the motor prior to
expiration of warranty will void the
warranty. If repairs are required, see
troubleshooting chart.
4. Inlet should be kept clean and free of
all foreign objects and inspect annually.
A clogged inlet will damage pump.
5. Pump should be checked monthly for
proper operation.
This pump contains
dielectric oil for
cooling. This oil can be harmful to the
environment. Check the state
environmental laws before disposing this
oil.
!
WARNING
Maintenance
Always
disconnect
the electrical supply before
attempting to install, service,
relocate or perform any
maintenance. If the power source is out of
sight, lock and tag in the open (off)
position to prevent unexpected power
application. Failure to do so could result in
fatal electrical shock. Only qualified
electricians should repair this unit.
Improper repair could result in fatal
electrical shock.
1. Let the pump cool for a minimum of
two hours before servicing because the
pump contains hot oil under pressure
and the motor is hot.
!
DANGER
Operating Instructions And Parts Manual
Troubleshooting Chart
Symptom
Possible Cause(s)
Corrective Action
Pump will not start or
run
Pump starts and stops
too often
Pump will not shut off
or thermal protector
turns off
Pump operates but
delivers little or no
water
1. Blown fuse
2. Low line voltage
3. Defective motor
4. Defective float switch
5. Impeller bound-up
6. Float obstructed
1. Backflow of water from piping
2. Faulty float switch
1. Defective float switch
2. Obstacle in piping
3. Float obstructed
1. Low line voltage
2. Plugged impeller
1. Replace with proper sized fuse or reset breaker
2. If voltage is under 108 volts, check wiring size
3. Replace pump
4. Replace float switch
5. Remove housing; remove blockage
6. Make sure float moves freely up and down
1. Install or replace check valve (Wayne check valve kit #66005-WYN)
2. Replace float switch
1. Replace float switch
2. Remove pump; clean pump and piping
3. Make sure float moves freely up and down
1. If voltage is under 108 volts, check wiring size
2. Clean out impeller
Specifications
Power supply requirements
120V, 60 hz
Motor
Single phase, oil
filled
Liquid temperature range
40°F to 120°F
Circuit requirements
15 amps (min)
Dimensions
11” high x 9” base
Cut-in level (factory set)
Tether 14”
Cut-out level (factory set)
Tether 7”
Construction
Motor housing
Thermoplastic
Volute
Thermoplastic
Impeller
Thermoplastic
Shaft
Stainless steel
Seals
Buna N
Discharge
1
1
/
2
” NPT
Limited Warranty
For one year from the date of purchase, Wayne Home Equipment Division
("Wayne") will repair or replace, at its option, for the original purchaser any part or
parts of its Sump Pumps or Water Pumps (“Product”) found upon examination by
Wayne to be defective in materials or workmanship. Please call Wayne (800-237-
0987) for instructions or see your dealer. Be prepared to provide the model number
and the serial number when exercising this warranty. All transportation charges on
Products or parts submitted for repair or replacement must be paid by purchaser.
This Limited Warranty does not cover Products which have been damaged as a result
of accident, abuse, misuse, neglect, improper installation, improper maintenance, or
failure to operate in accordance with Wayne’s written instructions.
THERE IS NO OTHER EXPRESS WARRANTY. IMPLIED WARRANTIES, INCLUDING
THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE
LIMITED TO ONE YEAR FROM THE DATE OF PURCHASE. THIS IS THE EXCLUSIVE
REMEDY AND ANY LIABILITY FOR ANY AND ALL INDIRECT OR CONSEQUENTIAL
DAMAGES OR EXPENSES WHATSOEVER IS EXCLUDED.
Some states do not allow limitations on how long an implied warranty lasts, or do
not allow the exclusions or limitations of incidental or consequential damages, so
the above limitations might not apply to you. This limited warranty gives you specific
legal rights, and you may also have other legal rights which vary from state to state.
In no event, whether as a result of breach of contract warranty, tort (including
negligence) or otherwise, shall Wayne or its suppliers be liable for any special,
consequential, incidental or penal damages including, but not limited to loss of profit
or revenues, loss of use of the products or any associated equipment, damage to
associated equipment, cost of capital, cost of substitute products, facilities, services or
replacement power, downtime costs, or claims of buyer’s customers for such damages.
You
MUST
retain your purchase receipt along with this form. In the event you need to
exercise a warranty claim, you
MUST
send a
copy
of the purchase receipt along with
the material or correspondence. Please call Wayne (800-237-0987) for return
authorization and instructions.
DO NOT MAIL THIS FORM TO WAYNE.
Use this form only to maintain your records.
MODEL NO._______________ SERIAL NO.__________________________ INSTALLATION
DATE_____________
ATTACH YOUR RECEIPT HERE
Replacement Parts List – For Replacement Parts,
call
1-800-237-0987
Only use factory parts to repair this pump.
Ref.
Part Number
No.
Description
1
Power Cord
30019-001
2
Float Switch
31039-001
3
Shaft Seal
21010-001
4
Volute Cover
28104-001
5
Impeller
28105-001
6
Volute Gasket
19048-001
7
Volute Base
28106-001
Address parts correspondence to:
Wayne Home Equipment
100 Production Drive
Harrison, OH 45030 U.S.A.
Please provide following information:
- Model number
- Serial number (if any)
- Part descriptions and number as shown
in parts list
2
3
5
6
7
1
4