background image

2. Disassembly of the motor prior to

expiration of warranty will void the
warranty. If repairs are required, see
troubleshooting chart.

4. Inlet should be kept clean and free of

all foreign objects and inspect annually.
A clogged inlet will damage pump.

5. Pump should be checked monthly for

proper operation.  

This pump contains 
dielectric oil for

cooling. This oil can be harmful to the
environment. Check the state
environmental laws before disposing this
oil.

!

WARNING

Maintenance

Always 
disconnect

the electrical supply before
attempting to install, service,
relocate or perform any
maintenance. If the power source is out of
sight, lock and tag in the open (off)
position  to prevent unexpected power
application. Failure to do so could result in
fatal electrical shock. Only qualified
electricians should repair this unit.
Improper repair could result in fatal
electrical shock.

1. Let the pump cool for a minimum of

two hours before servicing because the
pump contains hot oil under pressure
and the motor is hot.

!

DANGER

Operating Instructions And Parts Manual

Troubleshooting Chart

Symptom

Possible Cause(s)

Corrective Action

Pump will not start or
run

Pump starts and stops
too often

Pump will not shut off
or thermal protector
turns off

Pump operates but
delivers little or no
water

1. Blown fuse
2. Low line voltage
3. Defective motor
4. Defective float switch
5. Impeller bound-up
6. Float obstructed

1. Backflow of water from piping
2. Faulty float switch

1. Defective float switch
2. Obstacle in piping
3. Float obstructed

1. Low line voltage
2. Plugged impeller

1. Replace with proper sized fuse or reset breaker
2. If voltage is under 108 volts, check wiring size
3. Replace pump
4. Replace float switch
5. Remove housing; remove blockage
6. Make sure float moves freely up and down

1. Install or replace check valve (Wayne check valve kit #66005-WYN)
2. Replace float switch

1. Replace float switch
2. Remove pump; clean pump and piping
3. Make sure float moves freely up and down

1. If voltage is under 108 volts, check wiring size
2. Clean out impeller

Specifications

Power supply requirements

120V, 60 hz

Motor

Single phase, oil

filled

Liquid temperature range

40°F to 120°F

Circuit requirements

15 amps (min)

Dimensions

11” high x 9” base

Cut-in level (factory set)

Tether 14”

Cut-out level (factory set)

Tether 7”

Construction

Motor housing

Thermoplastic

Volute

Thermoplastic

Impeller

Thermoplastic

Shaft

Stainless steel

Seals

Buna N

Discharge

1

1

/

2

” NPT

Limited Warranty

For one year from the date of purchase, Wayne Home Equipment Division
("Wayne") will repair or replace, at its option, for the original purchaser any part or
parts of its Sump Pumps or Water Pumps (“Product”) found upon examination by
Wayne to be defective in materials or workmanship. Please call Wayne (800-237-
0987) for instructions or see your dealer. Be prepared to provide the model number
and the serial number when exercising this warranty. All transportation charges on
Products or parts submitted for repair or replacement must be paid by purchaser.
This Limited Warranty does not cover Products which have been damaged as a result
of accident, abuse, misuse, neglect, improper installation, improper maintenance, or
failure to operate in accordance with Wayne’s written instructions.

THERE IS NO OTHER EXPRESS WARRANTY. IMPLIED WARRANTIES, INCLUDING
THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE
LIMITED TO ONE YEAR  FROM THE DATE OF PURCHASE. THIS IS THE EXCLUSIVE
REMEDY AND ANY LIABILITY FOR ANY AND ALL INDIRECT OR CONSEQUENTIAL
DAMAGES OR EXPENSES WHATSOEVER IS EXCLUDED.

Some states do not allow limitations on how long an implied warranty lasts, or do
not allow the exclusions or limitations of incidental or consequential damages, so
the above limitations might not apply to you. This limited warranty gives you specific
legal rights, and you may also have other legal rights which vary from state to state.
In no event, whether as a result of breach of contract warranty, tort (including
negligence) or otherwise, shall Wayne or its suppliers be liable for any special,
consequential, incidental or penal damages including, but not limited to loss of profit
or revenues, loss of use of the products or any associated equipment, damage to
associated equipment, cost of capital, cost of substitute products, facilities, services or
replacement power, downtime costs, or claims of buyer’s customers for such damages.
You 

MUST

retain your purchase receipt along with this form. In the event you need to

exercise a warranty claim,  you 

MUST 

send a 

copy

of the purchase receipt along with

the material or correspondence. Please call Wayne (800-237-0987) for return
authorization and instructions.

DO NOT MAIL THIS FORM TO WAYNE. 

Use this form only to maintain your records.

MODEL NO._______________ SERIAL NO.__________________________  INSTALLATION
DATE_____________

ATTACH YOUR RECEIPT HERE

Replacement Parts List – For Replacement Parts, 
call 

1-800-237-0987

Only use factory parts to repair this pump.

Ref.

Part Number

No.

Description

1

Power Cord

30019-001

2

Float Switch

31039-001

3

Shaft Seal

21010-001

4

Volute Cover

28104-001

5

Impeller

28105-001

6

Volute Gasket

19048-001

7

Volute Base

28106-001

Address parts correspondence to:

Wayne Home Equipment
100 Production Drive
Harrison, OH 45030 U.S.A.

Please provide following information:

- Model number
- Serial number (if any)
- Part descriptions and number as shown

in parts list

2

3

5

6

7

1

4

Отзывы: