E-4
PSC5000 Serial Absolute Encoder Input Card II S-D4024
-
Life of external battery
:
Minimum
1.0 year
When using lithium battery of 3.6 V, 1500
milli-amp.-hour
-
Clearing time
:
Minimum
1.5 seconds
Maximum
4.0 seconds
Typical
2.5 seconds
When clearing interval of 5 seconds or
longer.
-
Clearing voltage
:
Minimum
4.0 V
Maximum
5.5 V
Typical
5.0 V
-
Time period to be required for
sending data after main power
is turned ON
:
Typical
1.0 milliseconds
Maximum
50 milliseconds
After EXT Vcc reached 4.45 V.
-
Data transmission cycle
:
84 microseconds
-
Output current of line driver
:
OH: -15 milli-amps
OL: 15 milli-amps
-
Bypass capacitor
:
Between frame ground (main portion) and
0 V:
0.22 micro-Farad (100 WV)
Between frame ground (main portion) and
main power supply voltage:
0.22 micro-Farad (100 WV)
Ambient Conditions
-
Operating temperature
:
0 to 70 degree C (32 to 158 degree F)
(no condensation)
-
Storage temperature
:
-20 to 80 degree C (-4 to 176 degree F)
(no condensation)
-
Humidity
:
Less than 90% RH (no condensation)
-
Vibration
:
No fault occurred when 49 meter/square
second (20 to 2000 Hz sweep) was
applied to three directions of X, Y and Z
for 2 hours.
-
Shock
:
No fault occurred when 980 meter/square
second (half sine wave of 6 ms) was
applied to three directions of X, Y and Z
for 2 hours.
Содержание S-ABS II Card
Страница 4: ...II PSC5000 Serial Absolute Encoder Input Card II S D4024...
Страница 6: ...IV PSC5000 Serial Absolute Encoder Input Card II S D4024...
Страница 8: ...VI PSC5000 Serial Absolute Encoder Input Card II S D4024...
Страница 18: ...3 6 PSC5000 Serial Absolute Encoder Input Card II S D4024...
Страница 26: ...5 2 PSC5000 Serial Absolute Encoder Input Card II S D4024...
Страница 30: ...A 2 PSC5000 Serial Absolute Encoder Input Card II S D4024...
Страница 32: ...B 2 PSC5000 Serial Absolute Encoder Input Card II S D4024...
Страница 44: ...E 6 PSC5000 Serial Absolute Encoder Input Card II S D4024...
Страница 51: ......