8.

Figure 4 — Model H Deluge System

Ordering Information

Specify (Ref. Figure 4):

Item No.

Component Part

Mfgr.

Description

Technical Bulletin

1

Deluge Riser Assembly

B

Model H

507

2

Releasing / Control Panel

C

Model PFC-4410-RC

Potter #5403550

Reliable 700

Batteries

12 VDC, 12 AMP Hours (90 Hours Backup) FM

12 VDC, 7 AMP Hours (60 Hours Backup)

Optional Accessories

CA2Z (Class A Wiring Module for Initiating Circuits)

CAM (Class A Wiring Module for Indicating Circuits)

ARM-1 / ARM-2 (Auxiliary Relay Module)

RA-4410-RC (Remote Annunciator)

3

Alarm Annunciator

A

Model SSM24-8 24 VDC / Polarized Bell

Model SSM24-10 24 VDC / Polarized Bell

Model MA24-D 24 VDC / Polarized Sounder

Model MASS24LO 24 VDC / Polarized Sounder Strobe

Reliable 700

4

Trouble Annunciator

A

Model SSM24-6 24 VDC / Polarized Bell

Model MA24-D 24 VDC / Polarized Sounder

Reliable 700

5

Manual Emergency Station (Elec.)

A

Model BNG-1 (SPDT) 1 & 2 Area Detection

Model BNG-1F (DPDT) Cross Zoned Detection

Reliable 700

6

Detection

Various

Smoke, Heat Detectors, etc.

Reliable 722

7

Sprinklers

B

Open Type

Reliable 104/106

System Equipment Manufacturers

(A) Notifier
(B)  The Reliable Automatic Sprinkler Co., Inc.
(C) Potter Electric Signal Company 

 

 

 

Patents

U.S. Patent number 5,720,351

Содержание H Deluge Riser

Страница 1: ...prinkler Co Inc 103 Fairview Park Drive Elmsford New York 10523 Model H Deluge Riser Assembly Bulletin 507 Rev D Bulletin 507 Rev D Instructions for Installation Operation Care and Maintenance 11 2 40mm Size Electric Actuation ...

Страница 2: ...lve has opened water flows from the supply through the Deluge Riser into the piping system and to the alarm initiating water flow pressure switch After system shutdown and draining the Deluge Riser is eas ily reset without special tools by first restoring detection devic es to the ready condition Once the detection system is ready the releasing control panel can be reset which automatically resets...

Страница 3: ...d and not leaking by performing Step 6 above The automatic drain valve Item 38 monitors internal leakage Push in on its plunger to be sure ball check is off its seat If no water appears the Deluge Riser Assembly is leak tight 1 2 3 4 5 6 7 1 2 3 Operation test Open the solenoid valve Item 4 us ing the procedure in Step 5 above Note Operation test will cause full flow into the deluge system unless ...

Страница 4: ...5306209 Clamping Ring OETIKER 515 2 23 95306210 Clamping Ring OETIKER 575 2 24 95106905 Plate Base 1 25 98543204 Nipple X 6 Lg Galv 1 26 94616910 Nameplate 1 Deluge System 1 27 94606910 Name Plate Manual Emergency Station 1 28 6999991339 Switch Pressure Eps10 1 1 6999992366 Switch Pressure Epsa10 2 30 98614403 Plug Galv 2 31 98614401 Plug Galv 1 32 98750025 Cross 2 X 1 Zinc Coated 1 33 98085680 Co...

Страница 5: ...xperienced contact Reliable Technical Services before any field adjustment is made Should replacement parts be needed use only Reliable supplied parts When ordering specify part number name size model and serial number of the unit Figure 2 ...

Страница 6: ...Maximum retightening torque on cover screws is 135 inch lbs 15 25 N m Replacement Parts When ordering replacement parts kit specify part number P N 6999991583 Parts includ ed in each kit are marked with an asterisk See ex ploded view Figure 3 Maintenance of Emergency Station Valve This valve Item 2 is not field serviceable In the event that leakage is occurring it must by replaced with a new manua...

Страница 7: ...em description and applicable codes for minimum requirements The valve must be inspected at least monthly for cracks corrosion leakage etc and cleaned repaired or re placed or replaced as necessary If leakage is suspected through the solenoid valve the valve diaphragms and seats should be inspected and if necessary repaired or replaced WARNING CLOSE SYSTEM CONTROL VALVE TURN OFF POWER SUPPLY AND D...

Страница 8: ... Remote Annunciator 3 Alarm Annunciator A Model SSM24 8 24 VDC Polarized Bell Model SSM24 10 24 VDC Polarized Bell Model MA24 D 24 VDC Polarized Sounder Model MASS24LO 24 VDC Polarized Sounder Strobe Reliable 700 4 Trouble Annunciator A Model SSM24 6 24 VDC Polarized Bell Model MA24 D 24 VDC Polarized Sounder Reliable 700 5 Manual Emergency Station Elec A Model BNG 1 SPDT 1 2 Area Detection Model ...

Страница 9: ...9 Installation Measurements ...

Страница 10: ...throughout the United States Canada and foreign countries Automatic sprinklers Flush automatic sprinklers Recessed automatic sprinklers Concealed automatic sprinklers Adjustable automatic sprinklers Dry automatic sprinklers Intermediate level sprinklers Open sprinklers Spray nozzles Alarm valves Retarding chambers Dry pipe valves Accelerators for dry pipe valves Mechanical sprinkler alarms Electri...

Отзывы: