background image

The Reliable Automatic Sprinkler Co., Inc.

(800) 431-1588    

Sales Offices

(800) 848-6051    

Sales Fax

(914) 829-2042    

Corporate Offices

www.reliablesprinkler.com   Internet Address

Manufactured by

Recycled

Paper

Revision lines indicate updated or new data.

EG. Printed in U.S.A 08/11

P/N 9999970299

The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory 

Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable.

Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly 

qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries.

Model F156 & F156 Recessed Sprinklers

Application

Model F156 and F156 Recessed sprinklers are used in fixed 

fire protection systems: Wet, Dry, Deluge or Preaction.  Care 
must exercised that the orifice size, temperature rating, deflector 
style and sprinkler type are in accordance with the latest pub-
lished standards of the National Fire Protection Association or 
the approving Authority Having Jurisdiction Installation. 

Installation

Model F156 Series sprinklers are standard response sprinklers 

intended for installation as  specified in NFPA 13. They must also 
be installed with the Model D Sprinkler Wrench specifically de-
signed by Reliable for use with these sprinklers.

The Model F156 Recessed Sprinklers are to be installed with a 

maximum recess of ¾ inch (19mm). The Model F1, F2, and FP 
Escutcheon illustrated are the only recessed escutcheon to be 
used with the Model F156 Recessed Sprinklers. The use of any 
other recessed escutcheon will void all approvals and negate 
all warranties. When installing Model F156 Recessed Sprinklers 
use the Model GFR2 Sprinkler Wrench. Any other type of wrench 
may damage these sprinklers.

Note:

 A leak tight ½” NPT (R1/2) sprinkler joint can be obtained with a torque 

of 8-18 ft-lbs (10,8 - 24,4 N-m).  Do not tighten sprinklers over maximum recom-
mended torque.  It may cause leakage or impairment of the sprinklers.

Glass bulb sprinklers have orange covers to protect the bulb 

during the installation process. REMOVE THIS PROTECTION 
ONLY AFTER THE SYSTEM HAS BEEN HYDROSTATICALLY 
TESTED AND, WHEN APPLICABLE, THE ESCUTCHEONS 
HAVE BEEN INSTALLED. RASCO wrenches are designed to 
install sprinklers when covers are in place.

Ordering Information 

Specify: 

1.  Sprinkler Model 
2.  Sprinkler Type 
3.  Orifice Size 
4.  Deflector Type
5.  Temperature Rating:

   - Specify when ordering

   - Model F156 Pendent Sprinkler

6.  Sprinkler Finish 
7.  Escutcheon Finish (where   applicable)  

Note:

 When Model F156 Recessed Sprinklers are ordered, the sprin-

klers and escutcheons are packaged separately.

Escutcheon Data 

(1)

Escutcheon

Model

Approvals Adjustment

“A”

Dimension

Face of Fitting to 

Ceiling or Wall

Dimension

F1

1,3,4

Max Recessed

Min Recessed

1

1

/

2

” (38.1mm)

3

/

4

” (19.1mm)

3

/

16

” - 

15

/

16

(5m - 24mm)

F2

1,2,3,4

Max Recessed

Min Recessed

1

1

/

2

” (38.1mm) 

1” (25mm)

3

/

16

” - 

11

/

16

(5m - 17mm)

FP Push-on/ 

Thread-off

1,4

Max Recessed

Min Recessed

7

/

16

” (11mm) 

15

/

16

” (24mm)

1

1

/

2

” (38.1mm)

1” (25mm)

(1)

 SIN: RA1335 - cULus and FM permits use with F1 or F2 escutcheons for light 

hazard only.

Maintenance

The Models F156 and F156 Recessed Sprinklers should be 

inspected quarterly and the sprinkler system maintained in 
accordance with NFPA 25.  Do not clean sprinklers with soap 
and water, ammonia or any other cleaning fluid.  Remove any 
sprinkler which has been painted (other than factory applied) 
or damaged in any way.  A stock of spare sprinklers should be 
maintained to allow quick replacement of damaged or operated 
sprinklers.  Prior to installation, sprinklers should be maintained 
in the original cartons and packaging until used to minimize the 
potential for damage to sprinklers that would cause improper 
operation or non-operation.

Temperature Ratings

Classification

Sprinkler

Temperature

Max. Ambient 

Temp.

Bulb 

Color

°C

°F

Ordinary
Ordinary

Intermediate
Intermediate

High

(1)

Extra High

(1)

57
68
79
93

141
182

135 
155
175
200
286
360

100°F (38°C) 
100°F (38°C)
150°F (66°C)
150°F (66°C)

225°F (107°C)
300°F (149°C)

Orange

Red

Yellow
Green

Blue

Mauve

(1)

 Not available for recessed Sprinklers.

Maximum Working Pressure

175 psi (12 bar)
100% Factory tested hydrostatically to 500 psi (34.5 bar)

Finish

(1)

Standard Finishes

Sprinkler

Escutcheon

Bronze
Chrome
Polyester Coated 

(6)(7)

Brass
Chrome
White Painted

Special Application Finishes

Sprinkler

Escutcheon

Bright Brass 

(2)

Black Plated
Black Paint 

(3)

Off White 

(3)

Satin Chrome
Lead Plated 

(3)(4)(8)

Wax Coated 

(3)(4)(5)(8)

Wax Over Lead 

(3)(4)(5)(8)

Bright Brass
Black Plated
Black Paint
Off White
Satin Chrome

(1)

 Other colors and finishes are available on special order. Consult factory for 

details.

(2) 

200°F (93°C) maximum.

(3) 

UL and ULC listed only.

(4) 

155°F to 200°F (68°C to 93°C) ratings only.

(5) 

286°F (141°C) sprinklers may be coated for ambient conditions not exceeding 

150°F (66°C).

(6) 

cULus listed “corrosion resistant” applies to SIN Number RA1325 (Upright) 

RA1335 (HSW), RA1385(VSW) and RA1314 (Pendent) in standard black or 
white.

(7)

 FM Approved finish as “Polyester Coated” applies only to SIN number RA1314 

(Pendent) in standard black or white.

(8)

 FM Approved finish applies only to SIN number RA1335 & RA1385.

Содержание F156 Series

Страница 1: ...Series Recessed escutcheon is highly ad justable The two piece construction makes field installa tion a very easy and rapid task This also allows ceiling panels to later be removed without shutting down the fire protection system thus facilitating maintenance of above ceiling services The F156 Series Automatic Sprinkler utilizes a 5 0 mm frangible glass bulb The glass bulb consists of an ac curate...

Страница 2: ...2 25 57mm 1 2 3 4 RA1325 2 RA1314 2 3 Conventional Install in Upright or Pendent Position 15mm 1 NPT R 5 6 80 57mm 3 4 RA1375 1 Refer to Bulletin 024 for Special Response Sprinklers F1S5 56 2 cULus Listed corrosion resistant Polyester coated sprinkler 3 Polyester coated FM Approved sprinkler Model F156 Recessed Pendent Sprinkler 1 Installation Wrench Model GFR2 Sprinkler Wrench Installation Data N...

Страница 3: ...5 6 8 0 2 25 57mm 1 2 3 RA1385 1 1 LPC Approval is pendent only 57 C through 141 C ratings 2 cULus Listed corrosion resistant Polyester coated sprinkler Model F156 Horizontal Sidewall Sprinkler Deflector HSW Installation Wrench Model D Sprinkler Wrench Installation Data Horizontal Sidewall Nominal Orifice Thread Size Nominal K Factor Sprinkler Height Approval Organizations Sprinkler Identification...

Страница 4: ...inkler Type 3 Orifice Size 4 Deflector Type 5 Temperature Rating Specify when ordering Model F156 Pendent Sprinkler 6 Sprinkler Finish 7 Escutcheon Finish where applicable Note When Model F156 Recessed Sprinklers are ordered the sprin klers and escutcheons are packaged separately Escutcheon Data 1 Escutcheon Model Approvals Adjustment A Dimension Face of Fitting to Ceiling or Wall Dimension F1 1 3...

Отзывы: