background image

Model F1-56-300 Pendent

Model F1-56-300 Upright

F1-56-300 Series Sprinklers Summary

Sprinkler 

Model

K-Factor gpm/psi

1/2

 

(lpm/bar

1/2

)

Orientation

Listings & Approvals

Max. Working Pressure 

psi (bar)

Sprinkler 

Identification 

Number (SIN)

F1-56-300

5.6 (80)

Upright

cULus

300 (20.7)

RA2525

Pendent

RA2514

Table A

Note:

 Not all versions of the product are shown.

Features

• 

Standard coverage standard-response sprinklers

• 

300 psi (20.7 bar) rated

• 

Upright and pendent deflectors

• 

Low profile, compact design

• 

Available in a wide variety of finishes

Product Description

Reliable Model F1-56-300 series sprinklers are 300 psi (20.7 bar) 

rated, standard-response standard spray automatic fire sprinklers 
utilizing a 5.0 mm glass bulb thermal element.

Pendent sprinklers may be installed exposed or surface mounted 
using escutcheons such as the Reliable Models B, C, or HB 
(reference Technical Bulletin 204). When installed recessed, the 
Model F1-56-300 series sprinklers are specifically listed with and 
may only be installed with Reliable listed recessed escutcheons. 
Refer to the technical information on the following pages for 
specific listings for recessed and concealed installations and refer 
to Figure 3 for dimensional information.

When fitted with an approved water shield, these sprinklers may 
considered intermediate sprinklers for use in racks, below grated 
walkways, and other areas where intermediate level sprinklers are 

required.

Table A provides a summary of the approvals and availability 
of specific Model F1 series sprinkler configurations. Additional 
technical information for each sprinkler model is provided on the 

following pages.

Note:

 This bulletin may contain information on New and Legacy 

sprinklers that reflects a dimensional change only. 

Sprinkler Identification Number (SIN), application, performance, 

and listings/approval are not otherwise affected. Sprinklers with 

New frames will include the suffix “N” in the order.

www.reliablesprinkler.com

K-factor 5.6 (80) 

F1-56-300 Series 

Standard Response Sprinklers

Bulletin 075 October 2022

Содержание F1-56-300 Series

Страница 1: ...1 56 300 series sprinklers are specifically listed with and may only be installed with Reliable listed recessed escutcheons Refer to the technical information on the following pages for specific listings for recessed and concealed installations and refer to Figure 3 for dimensional information When fitted with an approved water shield these sprinklers may considered intermediate sprinklers for use...

Страница 2: ...nse Temperature Ratings 135 F 57 C 155 F 68 C 175 F 79 C 200 F 93 C 286 F 141 C 360 F 182 C Guards Shields New Frame F 1 Guard F 3 Guard with Shield Guards and Shields Legacy Frame C 3 Guard with Shield D 1 Guard D 3 Guard with Shield Sprinkler Wrench Model W2 Model J New frame with guard installed Model JD Legacy frame with guard installed Listings and Approvals cULus Listed Model F1 56 300 Uprig...

Страница 3: ...7 Guard F 8 Guard Shield Kit S 1 Shield Guards and Shields Legacy Frame D 1 Guard D 5 Guard with Shield S 1 Shield Sprinkler Wrenches Model W2 non recessed Model W4 recessed or concealed Model J New frame with guard installed Model JD Legacy frame with guard installed Listings and Approvals cULus Listed Notes 1 286 F 141 C and higher temperature rated sprinkler not listed for recessed use 2 Not su...

Страница 4: ... mm Minimum Recess Maximum Recess 1 1 4 32 mm Face of Fitting to Face of Ceiling 7 8 22 mm at Max Recess 3 8 10 mm at Min Recess 2 1 4 57 mm Dia Hole in Ceiling 1 15 16 49 mm Dia 2 1 2 64 mm Dia Hole in Ceiling Models F1 F1FR Pendent Sprinkler with Model F2 Recessed Escutcheon 1 2 13mm Nominal Adjustment F1_REC_PEND Reducing Fitting Reducing Fitting Reducing Fitting Note Model FP recessed assembli...

Страница 5: ...ester 3 White Polyester Satin Chrome Custom Color Polyester Custom Color Polyester 3 Lead 3 Wax 3 6 Wax over Lead 3 6 Notes 1 Paint or any other coating applied over the factory finish will void all approvals and warranties 2 Model FP escutcheons utilize a galvanized steel cup with a finished trim ring 3 cULus Listed as corrosion resistant 4 For 200 F 93 C maximum temperature rated sprinklers only...

Страница 6: ...ing Model F1 56 300 Deflector Orientation Upright Pendent Temperature Rating See sprinkler technical specifications Sprinkler Finish See Table B Recessed Escutcheon F1 F2 FP Escutcheon Finish See Table B Sprinkler Wrench Model W2 upright non recessed pendent Model W4 recessed concealed pendent Model J with guard installed Note 286 F 141 C and higher temperature rated sprinklers are not listed to b...

Отзывы: