HOSES AND FITTINGS
There exists the potential for shock in using anything other than certifi ed
nonconductive hoses and hydraulic oil with dielectric properties, when
using system components near energized electrical lines. Failure to
recognize these conditions could cause electrocution.
Hoses & fi ttings used with this tool must comply with S.A.E. J1273
which covers recommended practice for selection, installation, and
maintenance of hose and hose assemblies.
The correct hoses and
fi ttings are available from your supplier.
WARNING:
Failure to comply with these warnings could result in severe bodily injury.
WARNING
UNIT/HOSE CONNECTIONS
ALWAYS DISCONNECT
pump/power source and move toggle
switch to
OFF
before connecting or disconnecting any components.
ALWAYS DEPRESSURIZE
hydraulic system, before slowly
disconnecting this unit or any of the systems components.
ALWAYS TIGHTEN
couplings completely. Loose or improperly
tightened couplings will not allow fluid to pass through the
hose creating a blockage in the supply or return line.
ALWAYS INSPECT HOSES AND CONNECTORS
before
connection to tool. Replace or repair if any signs of wear, damage,
or leakage are evident. Leakage is a sign of deterioration in
component parts. Worn or leaking parts must be repaired
or replaced, or tool damage and/or severe injury could result.
WARNING
HOSE INSTALLATION
ALWAYS ENSURE CONNECTORS ARE CLEAN
Care must be taken to assure the correct connection of the hoses to
the pressure and return (tank) ports.
Connect the return hose to the return (tank) port on the power source,
then to the return port on the tool.
Connect the pressure hose to the pressure port on the tool, then to
the “P” pressure port on the power source.
Operation with hydraulic
fl
ow reversed can cause malfunction.
Failure to comply with warnings may result in severe injury or death
.
CAUTION