Reliable Equipment REL-EP-115 Скачать руководство пользователя страница 7

7

Safe Handling

HYDRAULIC FLUID MAY CAUSE SKIN IRRITATION.

Prevent hydraulic fl uid from making contact with skin.

IN THE EVENT OF SKIN CONTACT  

immediately wash  thoroughly.

Failure to observe this warning could result in injury.

CAUTION

Electrical Shock Hazard

Use  only  certified  non-conductive  hoses  and  fittings.

Always  wear  and  use  the  necessary  clothing,  equipment  and 
safety  practices  to  protect  against  electrical  shock.  Failure  to 
follow  these  rules  can  result  in  serious  personal  injury  or  death. 

WARNING

CAUTION

General Safety 

Ensure  that  all  fellow  employees  and  bystanders  are  clear 
and  protected  from  possible  injury  caused  by  this  tool  or  the 
operations  being  performed.  Persons  in  close  proximity  could 
be injured and property damaged if the tool were to malfunction.
This  tool  should  always  be  used  within  the  limits  and  purposes 
stated by the product manufacturer. Abuse or usage beyond the 
manufacturers’ intended purposes could cause damage to the tool 
and severe injury to the operator.

Burn Hazard

Do Not  connect or disconnect tool, hoses or fi ttings while power 
source is running or while hydraulic fl uid is hot.
Hot hydraulic fl uid may cause serious burns.
Failure to observe this warning could result in serious injury.

WARNING

If  you  have  any  questions  regarding  the  information  found  in  this
manual  please  contact 

RELIABLE EQUIPMENT

  before  continuing.

Phone: 

215-357-3500

    Toll  Free: 

800-966-3530

    Fax: 

215-357-9193

NOTICE

Содержание REL-EP-115

Страница 1: ...IC HYDRAULIC PUMP The REL EP 115 230 single and double acting hydraulic pump features manual lever operation continuous duty performance and a two stage pumping system to ensure rapid tool advance The...

Страница 2: ...______________________________________ PHONE _____________________ FAX __________________________________ SERIAL NUMBER ____________________________________________________ DATE OF PURCHASE __________...

Страница 3: ...Assembly Fig 2 19 PARTS LISTS Major Components Inner Pump 20 Valve Block Assembly 21 DRAWING Valve Block Assembly Fig 3 22 High Pressure Pump Block Fig 4 Manifold Outlet Block Fig 5 23 PARTS LISTS Hi...

Страница 4: ...8A continuous duty motor REL EP 230 230V 10A continuousduty REL GB 10 8 75 ft lb torque 190cc Briggs Stratton OHV 4 stroke engine FEATURES 10 000 PSI high pressure pump Fast two stage pumping system F...

Страница 5: ...ye protection to avoid injury from flying debris or hydraulic oil leaks Failure to do so can result in serious personal injury Hard Hat WARNING Always wear a hard hat to avoid injury from falling debr...

Страница 6: ...OSES AND COUPLINGS before each use Repair or replace if any cracking leakage wear or damage is is found Worn or damaged hoses may fail resulting in personal injury or property damage CLEAR WORK AREA o...

Страница 7: ...le injury caused by this tool or the operations being performed Persons in close proximity could be injured and property damaged if the tool were to malfunction This tool should always be used within...

Страница 8: ...ts ALWAYS TIGHTEN couplings completely Loose or improperly tightened couplings will not allow fluid to pass through the hose creating a blockage in the supply or return line ALWAYS INSPECT HOSES AND C...

Страница 9: ...210O F 99O C 40 minimum FLASH POINT 340O F min 170O C min POUR POINT 30O F min 34O C min DISCONNECTING HOSES WARNING DO NOT disconnect the tool hoses or fittings while the tool is running hot or under...

Страница 10: ...Operating Pressure Factory Pre set Relief Valve 10 000 psi Return Relief Setting Factory Pre set 3 500 psi Oil Reservoir 2 Gallons Oil Delivery Per Minute 160 cubic inches at 100 psi 60 cubic inches...

Страница 11: ...Remove vent valve to add proper uid as needed Turn dial to S A for single acting applications Note For ALL Single Acting and Double Acting Remote Valve Applications set selector to S A Turn dial to D...

Страница 12: ...n place of pendant switch for single acting operations Turn toggle switch ON for remote valve operations Press and hold button down to operate tool S A Ram will retract upon release D A Move valve han...

Страница 13: ...alve may also be used for remote applications Connect Connect Return Tank hose to RIGHT Male REV valve block coupling ENSURE THAT ALL CONNECTIONS ARE TIGHT AND SECURE 3 Set D A S A selector knob to th...

Страница 14: ...A S A selector knob is located on the right side of the lever valve block 4 Ensure that the valve lever is in the RETURN RET position 5 Start motor when ready to begin tool operation If a pendant swit...

Страница 15: ...dirty connections or accumulation of sediment FLUID CONTAMINATION Cover the ends of fittings with a dust cap when disconnected This will help keep the fluid from becoming contaminated See Reservoir Cl...

Страница 16: ...heck for leaks Worn or damaged components Replace worn or damaged components Pump operation is erratic Hydraulic fluid not warm Allow oil to warm up Dirt or contaminants in tool Clean and reassemble A...

Страница 17: ...g or disconnecting system components ALWAYS DEPRESSURIZE hydraulic system before slowly disconnecting this unit or any of the system s components Disconnect pump from any hoses or tools Remove the scr...

Страница 18: ...PONENTS ELECTRIC PUMP If you have any questions regarding the information found in this manual please contact RELIABLE EQUIPMENT at 800 966 3530 or FAX 215 357 9193 75 92 2 3 48 56 67 68 66 76 49 57 5...

Страница 19: ...URE 2 INNER PUMP ASSEMBLY Items indicated with an on the parts list are included in Seal Kit Part R40200 26 31 41 31 33 79 95 20 13 25 17 17 18 16 49 12 11 15 14 44 51 34 31 4 47 43 X10 3 96 94 59 99...

Страница 20: ...1 4 R40004 MANIFOLD PLATE 1 11 R40011 BEARING 1 12 R40012 CENTER BLOCK 1 13 R40013 DRIVESHAFT 1 14 R40014 RETAINING RING 1 15 R40015 HOUSING RETAINING RING 1 16 R40016 CAM BEARING ASSY 1 17 12769 THRU...

Страница 21: ...ET SCREW 1 130 R40130 SPRING PIN 1 4 X 1 2 1 131 R40063 DUMP PIPE 1 R40101 VALVE BODY 1 It is highly recommended that this unit be returned to RELIABLE EQUIPMENT or a factory trained and authorized se...

Страница 22: ...22...

Страница 23: ...23...

Страница 24: ...2744 BALL 3 8 DIA 1 31 R40031 O RING 9 32 R40032 TRANSFER TUBE 1 35 R40082 VALVE CLAMP 1 36 R40036 SCREW 2 38 R40038 B U RING 2 64 R40064 SCREW 2 80 R40080 VALVE TUBE 1 85 R40085 SUPPLY LINE DUMP VALV...

Страница 25: ...25...

Страница 26: ...hone 800 966 3530 Fax 215 357 9193 Visit us on the web at www Reliable Equip com If you have any questions regarding the information in this manual please contact RELIABLE EQUIPMENT at the address pho...

Отзывы: