RELACART CS-301VM Скачать руководство пользователя страница 24

Auto Closing Time :

10 sec

Digital Conference System

5) Unit volume

The  unit  volume  is  the  output  volume  of  the  built-in  speaker  of  the 

conference unit. The adjustment range is between -30dB and 0dB.

Press up and down keys to enter "unit volume", press "Enter" key to enter 

the following interface:

22

5.6.3 Voice activated mode

During  the  conference,  due  to  the  capacity  of  the  conference  unit  to 

speak  and  the  speech  mode  (when  the  chairman  priority  key  is  on,  the 
chairman  unit  is  unlimited  to  the  speech  capacity  and  mode  of  speaking),  if 
the delegate unit fails to turn off the microphone after the speech ends, Will 
affect other speakers. Therefore, the moderator can switch to "voice mode" 
as shown below and press "Enter" to enter the following interface to set the 
microphone auto-off time.

Press  the  up  and  down  keys  to  adjust  the  auto-off  time,  the  adjustment 

range  is  1  ~  15s,  the  system  default  auto-off  time  is  10s,  press  the  "Enter" 
key  to  confirm  the  setting,  so  that  after  the  conference  unit  finishes 
speaking,  the  system  starts  to  count,  shutdown  automatically,  in  order  to 
protect the normal and orderly meetings.

Unit

 

Volume

-30dB

0dB

5.6.4

 

Address setting

Press  Up  and  Down  keys  to  switch  to  "3.  Address  Setting"  and  press 

"Enter" key to enter the following interface:

Manual

 

Setting

1

First ID

1) Manually set, you can manually update the ID address of some conference 

units  or  the  ID  address  of  all  conference  units.  Through  the  up  and  down 
keys, adjust the first address of the conference unit. The adjustment range 
of  the  first  address  is  1  ~  249.  After  adjusting,  press  "Enter  "  key,  the 
system starts to set the address, and the conference central controller LCD 
screen displays the following interface:

Содержание CS-301VM

Страница 1: ...Digital Conference System Product Manual...

Страница 2: ...rm device 3 6 Connect with PC console 4 Set up and operate 4 1 Boot initialization 4 2 LCD initial interface operation 5 Main menu 5 1 Chairman priority setting 5 2 Unit status 5 3 The speech limit se...

Страница 3: ...llowing System advancement Digital conference system and conference attendance system intelligent central control system to achieve a seamless connection which has been the first in the industry to pr...

Страница 4: ...atements voting and other conference unit data Support 32K audio sampling frequency the frequency response of each channel can reach 20Hz 20KHz Has a limit function to speak on delegate unit can set 1...

Страница 5: ...CS 301VM x 1 Hanging ear x 2 Black screw x 6 Power cord x 1 Serial line x 1 Machine foot x 4 Product brochure x 1 Digital Conference System 1 5 Product packaging composition 3...

Страница 6: ...ng the volume adjustment interface the key is for increasing the volume c down arrow keys Switch between menu items and for selecting the next one When setting up the volume of speech and the limit of...

Страница 7: ...ector IN Connect control keyboard to control the camera OUT Connect camera Connect alarm equipment B type USB interface for upgrading the program TCP IP can connect with the computer to control the co...

Страница 8: ...Digital Conference System 3 Connection 3 1 System connection diagram 6...

Страница 9: ...the number of output interfaces will affect the number of conference units the specific data are as follows A repeater can provide power for the 20 conference unit in the case of multiple repeaters i...

Страница 10: ...ler support camera tracking function adjust the camera ID baud rate and protocol and then the correct connection as shown below you can use the upper computer software or keyboard to adjust the camera...

Страница 11: ...operate the camera by the ID number 3 5 Connect with alarm device CS 301VM conference central controller support alarm linkage function when the alarm port access 5V voltage signal all the conference...

Страница 12: ...uter you can run on the computer PC software through the upper computer software to complete more complex functions and control 10 Note Through the upper computer software for online operation set the...

Страница 13: ...ice mode auto off time Voice mode Unit volume Microphone gain background volume All Microphones Open Microphone Chinese English Language settings Mute ON System setting Recording setting open recordin...

Страница 14: ...and the system will select the speech volume by default and switch between number and mode of speech by pressing the up and down keys 1 Press the up and down keys to switch to quantity 2 Press Enter...

Страница 15: ...next delegate unit that presses the speak key automatically enters the multiplying state When the delegate unit microphones are closed the delegate unit that first enters the applied speaking state au...

Страница 16: ...u until you get back to the initial screen 5 1 Chairman priority setting 1 In the main menu interface press up and down keys to switch the menu select 1 Chairman priority key setting press Enter key t...

Страница 17: ...and down keys to switch the menu item select 2 Unit status press Enter key to enter the following interface View the status of the conference unit connected to the system The total number of conferen...

Страница 18: ...setting press Exit key to exit enter the following figure 5 Press the up and down keys to switch between OK and Exit select OK to exit the setting item select Exit to exit without saving setting the i...

Страница 19: ...dard mode and press Enter key to enter the interface shown as below The system default tracking mode is first in first out press the up and down keys to switch between first in first out VIP first and...

Страница 20: ...key to enter the following interface Press up and down keys to switch between Device Preference and Capacity Display Capacity display Switch to capacity display press Enter key to enter the following...

Страница 21: ...until you replace or unplug the storage disk as shown below The factory default setting of microphone gain is lower Before turning on the recording please adjust the microphone gain by 7 System Setup...

Страница 22: ...s to select On or Mute and press Enter to enter the following interface System menu display language options Chinese English Press the up and down keys to switch press the Enter key to select the mode...

Страница 23: ...rease or decrease rapidly 4 Microphone gain Microphone gain means the sensitivity of the microphone of the conference unit to capture the sound Press Up and Down keys to switch to Mic Gain and press E...

Страница 24: ...ce to set the microphone auto off time Press the up and down keys to adjust the auto off time the adjustment range is 1 15s the system default auto off time is 10s press the Enter key to confirm the s...

Страница 25: ...level7 main menu interface after initialization 5 6 5 System Parameters Press up and down keys switch to 4 System parameters press Enter key to enter the following interface Disp Addr 0 Current Addre...

Страница 26: ...tch between Factory Setting and About switch to About and press Enter to enter the following interface About You can check the machine type software version and hardware version Full Digital Conferenc...

Страница 27: ...output power 360W Sampling frequency 32KHz Frequency response 20Hz 20KHz Signal to noise ratio 80dB Total harmonic distortion 0 05 XLR output level 12dBV XLR output impedance 1k Static power consumpti...

Страница 28: ...number 3 If the POWER light is off the operation does not respond please check whether the power input of the device is in good condition or the output sound is disturbed Please check if the input an...

Страница 29: ...f the system 9 To maintain a good working environment of the ventilation easy to work equipment issued by the timely discharge of heat to avoid overheating and damage to equipment 10 Make sure the dev...

Страница 30: ...the risk of electric shock DO NOT open covers no user serviceable partsinside Refer servicing to qualified servicepersonnel only The exclamation mark in this triangle is a reminder that the user shou...

Страница 31: ...pany only provides products one year warranty period from the date of purchase by the user mainly to purchase invoices from the start 4 For one of the following situations the warranty service will no...

Отзывы: