REL Acoustics ‘Q’ range User manual
8
CONTROLS AND CONNECTIONS - QUAKE
1
2 3 4 5
6
7
8
9
1
Slam/Depth switch.
Changes the characteristics of the filter/roll off. Depth mode 20 – 100 Hz
Slam mode bass emphasised 50 – 150 Hz.
ONLY FITTED TO QUAKE AND Q150E
2
Roll off control
. Adjust to set the upper roll off frequency of the Sub Bass System.
3
MODE SWITCH.
Used to set phase* and to bypass crossover for Low Level input**.
Position 1 / Line: 0 degrees phase, crossover engaged low level input
Position 2 / LFE: 0 degrees phase, crossover bypassed for low level input
Position 3 / Line: 180 degrees phase, crossover engaged for low level input
Position 4 / LFE: 180 degrees phase, crossover bypassed for low level input
*PHASE SELECTION AFFECTS BOTH HI AND LO LEVEL INPUTS
**Crossover is always engaged for Hi level input regardless of mode switch position.
4
LO LEVEL
input volume control. Adjust for output level when using LO LEVEL phono input
or balanced line level input XLR socket.
5
HI LEVEL
input volume control. Adjust for output level when using HI INPUT Neutrik socket or
BAL HI INPUT Neutrik socket.
6
PC input
3.5mm jack socket. Used to connect the Sub Bass System to a computer.
7.
LFE input
phono socket. Used to connect the Sub Bass System to the LFE/Sub output of a
5.1 channel amplifier or processor.
8.
HI LEVEL
input Neutrik Speakon socket. Used to connect the Sub Bass System to the main
front speaker terminals on the amplifier.
9
IEC
Mains input socket.
MAX
MIN
LO LEVEL
MAX
MIN
106HZ
26HZ
HI LEVEL
ROLLOFF
POWER
41HZ
1
2
3
4
MODE
SLAM
DEPTH
CONTOUR
HI LEVEL
LFE
PC
CE
QUAKE
SOURCE
1
2
3
4
LINE
LFE
LINE
LFE
PHASE
0
0
180
deg
180
deg
MODE
SELECTOR
FUSE 2 A/T
~ 220-240 VAC 50-60
HZ
100 WATT MOSFET
SUB-BASS SPEAKER SYSTEM
PROTECTED BY
R
REL ACOUSTICS LTD NORTH ROAD BRIDGEND CF31 3TP UNITED KINGDOM
http://REL.net
FAX: +44 (0) 1656 766093