14
filter 2, and the Hi/Lo Level control on the remote changes the level of EQ filter 2. Each filter has a frequency
range from 20Hz to 90Hz. The level set of each filter is +/- 6 dB in 1/3 dB increments.
LED Display
An LED display is located on the upper right front of No.25. All functions that are user adjustable via the
remote control can be seen here. The display reverts to off a few seconds after adjustment. The top three
characters indicate the parameter being controlled by the remote and the bottom two numbers indicate
the value of the parameter controlled.
Parameter
Display
High/Low Level
HL
.1 Level
.1
Crossover Frequency
CO
Phase
PH
Parametric EQ1
E1
Parametric EQ2
E2
Ambient Control
No.25 has an array of ambient lights on each side, outboard of the feet. The intensity of these lights can
be controlled with the 4 position AMBITET CONTROL switch. Starting with the switch in the far counter
clockwise position, the lights are off, as the switch in moved to the next three positions, the intensity will
increase. The ambient lights can be triggered off for theater viewing with a common 12VDC trigger. 0V at
AMBIENT TRIG keeps the lights ON, +12V at this trigger input turns them OFF.
Remote Control Battery Installation
No.25’s Remote Control Unit requires two AAA batteries. These are not installed but are supplied. To install
or replace batteries in the Remote Control Unit, first remove the bottom aluminum cover by using the
supplied 2.5mm Hex key to loosen the two visible screws. With the bottom cover removed, you will see a
battery holder, which will accept two AAA batteries. Follow the images on the holder for proper orientation
of the batteries. After installing the batteries, test the unit by setting the SECURITY switch to UNLOCK and
turning one of the knobs. If the batteries are installed properly, you will see one of the red LEDs on the
remote control’s front panel illuminate. Replace the bottom cover and tighten the two screws using the
supplied Hex key. Battery life can be extended if the SECURITY toggle switch is left in the LOCK position
when the Remote Control is not in use.