Reka TR 500 Скачать руководство пользователя страница 4

4

During Operation

Cleaning and Maintenance

Replacement of Nozzles

Applying Hot-Melt

The quantity to be applied is determined by pulling the

trigger: the more you pull the more glue is dispensed.

When the feeding of glue sticks is stopped, the ball valve

integrated in the nozzle will close, thus preventing liquid

glue from leaking out.

When the glue is used up so that it stops flowing out

when the hand trigger is pressed, insert a new glue

stick.

Only use hot­melt that is suited to use with your

applicator. Please mind the respective working

temperature of the hot­melt (TR 500: approx. 115 ­

200°C; TR 501: approx. 195°C; TR 502, TR 505, 101:

approx. 190 ­ 200°C)*. This temperature is indicated in

the technical datasheet of the hot melt. This temperature

must not be exceeded, otherwise the glue may coke in

the glue applicator. Hot­melts on a polyamide basis are

particularly sensitive. Low­Melt hot­melts can only be

applied with the model TR 500 and the corresponding

temperature setting.

Having worked with some glue sticks, the glue gun

needs some time to reheat.

Never pull the trigger with force! If you feel resistance

when pulling the trigger, wait one or two minutes, so the

glue gun can melt the glue properly.

In case the nozzle is clogged or the hot­melt is not fully

melted, glue may flow out the glue stick inlet. Remove it

while the glue gun is lukewarm (approx. 40 °C). Do not

use any sharp or pointed tools.

The cable of the glue guns TR 500, 501 and 502 can be

removed for a short period of time. This enables the user

to apply glue to places that are difficult to access.

If the glue applicator isn't used for 30 minutes or more,

unplug it to preserve the hot­melt.

For your own safety: wear protective gloves and safety

goggles when you replace nozzles.

Always unplug the glue gun before replacing a nozzle!

Use heat­resistant gloves or a thick cloth for changing a

nozzle. Do not use tools like a nipper!

Only replace nozzles when the glue applicator is warm

(instrument temperature 60 – 80 °C ) and empty.

Replacing a nozzle when the applicator is cold may

damage the equipment. Replacing the nozzle when the

applicator is too hot, causes liquid glue to flow out.

Warning: Risk of burning!

The melting range as well as the melting point of the

used glue may be taken from the technical datasheet of

the respective glue.

An overview of the current Reka nozzle range can be

found on page 6 of the operational manual.

Never fill soiled glue into the melting tank. If you observe

all advices given in the operating manual, the glue

applicator does normally not need cleaning. The glue

contained in the applicator will remelt and can be used

for gluing again.

If the applicator is used very often, we recommend

having it maintained regularly. For this, fix a date with our

service department.

* PTC­devices are subject to temperature variation

Always deposit the glue gun on the wire stand or the

respective plate destined for this purpose.

After unplugging the device, unprocessed hot­melt glue

will stay in the glue gun. The glue remaining in the

gun will remelt and can be used during next use.

Содержание TR 500

Страница 1: ...TR 500 501 502 TR 505 TR 101 Operating Instructions Glue Gun TR 500 501 502 505 101 Translation from German to English...

Страница 2: ...Product Description 3 Start up and Control 3 During Operation 4 Cleaning and Maintenance 4 Replacement of Nozzles 4 Tips for Glueing 5 Trouble Shooting 5 Additional Information 6 Additional Nozzles 6...

Страница 3: ...elt When using the glue gun for the first time insert a hot melt stick You can process hot melt sticks of 90 300 mm length and 11 3 0 2mm diameter When the stick is used up to the point that the feed...

Страница 4: ...00 501 and 502 can be removed for a short period of time This enables the user to apply glue to places that are difficult to access If the glue applicator isn t used for 30 minutes or more unplug it t...

Страница 5: ...out to be bonded materials should be clean free of fats and oils and dry cold material like metal stone and ceramic should be pre heated hot hot melt should at first be applied to the surface which ac...

Страница 6: ...nal Nozzles Please contact us by Phone 49 721 970 780 Telefax 49 721 705 069 E Mail sale reka klebetechnik de Our mailing address is Reka Klebetechnik GmbH Co KG Siemensstr 6 D 76344 Eggenstein Intern...

Страница 7: ...is is to certify that the applicators above in the design marketed by us are in conformity with the following EC directives Until 15 01 2007 73 23 EEC from 16 01 2007 2006 95 EC until 19 07 2009 91 36...

Страница 8: ...echnik de TR 500 TR 501 TR 502 TR 505 TR 101 Power supply 230 V 230 V 230 V 230 V 230 V Power consumption 125 W 125 W 35W 500W 35 W 500W 35 W 500W Temperature control electronic electronic PTC PTC PTC...

Отзывы: