REITEL Polymat Скачать руководство пользователя страница 8

 

 

  Safety Notes 

  General Safety Notes 

  All equipment undergoes final inspection and testing before leaving our factory. However, 

if equipment is damaged during shipping or through any other circumstances, it must not 

be used in service. Please check the device regularly for damages. Damaged parts 

should be replaced immediately. 

  All power/air/water/gas sources should be rated for the demands of the device as listed in 

the technical data sheets. Maximum ratings must not be exceeded. All VDE (Verein 

Deutscher Elektro-Ingenieure) standards should be followed. Equipment should be 

grounded according to standards. 

  Adherence to valid regulations regarding necessary checks (e.g. according to Accident 

Prevention & Insurance or electrical equipment) is exclusively taken over by the 

buyer/user of this product. 

  This device has been designated to be used only for its intended purpose. All other 

applications must be prohibited for safety reasons as otherwise the manufacturer’s 

warranty expires. 

  The device should be set-up in a clean, well-ventilated room, if necessary under a hood. 

  Supporting surfaces should be straight, flat and adequately stable. 

 

Don’t place anything on top of the machine. 

  To avoid injury, appropriate protection should be worn (e.g. gloves, safety glasses, safety 

shoes, hearing protection etc.) 

  If the machine is defective or working improperly it must be taken out of service. In case 

of further use of the machine the owner will be held responsible for any consequential 

damage. 

  To prevent accidents from water, fire or explosion, all power/air/water/gas sources should 

be turned off after working hours and during breaks, and secured against unauthorized 

access. 

  When carrying out maintenance works or repairs or when opening the device always turn 

off the main power switch and unplug the whole unit. 

  Repairs should be carried out only by the manufacturer or by qualified and certified 

personnel appointed according to chapter 7 

– warranty. 

  In case of leaking water out of housing or tank shut down device and call service. 

  Check all hose connections for leak tightness, if necessary tighten hose clamps again 

 

 

Содержание Polymat

Страница 1: ...perating Instructions LABORATORY EQUIPMENT IN STAINLESS STEEL POLYMAT REITEL Feinwerktechnik GmbH Senfdamm 20 49152 Bad Essen Phone 49 0 5472 9432 0 Fax 49 0 5472 9432 40 www reitel com info reitel co...

Страница 2: ...unintended use The manufacturer shall not be responsible for any damages that may result thereby Prior to installation of the device operating instructions and especially the safety instructions must...

Страница 3: ...Y NOTES 8 SPECIFIC SAFETY NOTES 9 INSTALLATION 10 CONTROL PANEL 10 INSTALLATION 11 PREPARATION 11 OPERATION 11 INSTALLATION 11 PROGRAMMING 11 POLYMERISATION BELOW 100 CELSIUS 212 F 12 POLYMERISATION A...

Страница 4: ...ure regulator tap and drain hose Grease for maintenance see chapter 6 of the o ring bottle of 10 g Swivelling lever 16 for screwing into the lid 1 Insert perforated plate available as spare part on re...

Страница 5: ...6 Timer 7 Digital temperatur controller 8 Power cord 9 Compressed air connection 10 Safety valve 11 Pressure relief valve 12 Water outlet 13 Pressure control 14 Ball valve 15 Knurled screws 16 Swivel...

Страница 6: ...6 Digital temperature controller Rear side Lateral view Stainless steel tank 8 9 10 11 12 13 18 15 14 17...

Страница 7: ...r Width lever depth 330 330 290 380 mm Inner tank dimensions D H 220 190 mm Volume 7 l Filling 0 120 min Variable pressure 0 6 bar Temperature up to 100 C 212 F Option 120 C 248 F temp extension Sound...

Страница 8: ...acturer s warranty expires The device should be set up in a clean well ventilated room if necessary under a hood Supporting surfaces should be straight flat and adequately stable Don t place anything...

Страница 9: ...eep the housing clean and dry Never open the machine under pressure Check the gauge readings 3 Danger of splashing water hot steam or parts inside the unit Be careful when handling hot water risk of s...

Страница 10: ...on please refer to safety notes in chapter 2 Control panel After switching on the device performs a self test and the display indicates r1 5 It flashes approx 5 seconds followed by display of the curr...

Страница 11: ...heats to the last set temperature Operation Installation 1 Connect the unit plug to establish power supply The power switch 1 for switching on the device is located at the front of the polymerisation...

Страница 12: ...evice Open the ball valve 14 to drain water Polymerisation above 100 C 212 F Note The heating switches off after the timer has elapsed When the heating is activated again temperature might change over...

Страница 13: ...e c Check if o ring fits tighlty d Replace o ring Untight lid tank pressure too high Pressure regulator 11 adjusted too high max 6 bar Untight lid knurled screws not tight enough Fasten knurled screws...

Страница 14: ...lubricant OKS 1110 available on request Replace the o ring inside the lid semi annually Change the water once a week Clean the housing regularly with a damp cloth Note Clean and protect your device re...

Страница 15: ...ssed to the distributor the product was purchased from or directly to our service department Contact REITEL Feinwerktechnik GmbH Senfdamm 20 49152 Bad Essen Germany Phone 49 0 5472 9432 32 Service Dep...

Страница 16: ...ages due to faulty installation or insufficient maintenance of the product e g decalcification Damages due to natural disaster e g lightning water fire act of nature beyond control war inadequate line...

Страница 17: ...dvised to backup essential programs and data before sending for service 12 This warranty shall be interpreted in accordance with German law to the exclusion of UN sales law Place of jurisdiction is ou...

Страница 18: ...Regler O ring controller 1 Stck piece E7146300 Moosgummiprofil Sponge rubber profile 1 m E7851800 O Ring 34x3 mm f r Drehknopf Timer O ring 34x3 mm for timer rotary knob 1 Stck piece E6096500 R ndelsc...

Страница 19: ...19 EC Conformity Declaration...

Страница 20: ...pliance with Quality Management ISO 9001 2015 incorporating established standards REITEL Feinwerktechnik GmbH Senfdamm 20 49152 Bad Essen Phone 49 0 5472 9432 0 Fax 49 0 5472 9432 40 www reitel com in...

Отзывы: