Below, you see the connector allocation for an additional sensor with a current
consumption of less than 30mA.
If the additional sensor requires more current, an external voltage supply must be
used for the additional sensor. If not, we cannot grant that the weather station works
properly.
The two additional inputs are displayed in mV and can be adjusted via a Terminal-
program (e.g. Windows Terminal).
Connecting an
Additional Sensor
8
5
6
1
7
2
3
4
Gnd
Vcc
Additional sensor
+10..13VDC von der MWS5
Ground
Output of the additional
sensor (0..4.096V)
Additional Sensor with Voltage Supply by MWS5
8
5
6
1
7
2
3
4
Gnd
Vcc
External
Voltage Supply
Gnd
Vcc
Additional sensor
Output of the additional sensor
Ground
VCC of the external
voltage source
Additional Sensor with External
Voltage Supply