Data format
The data format of the transmitted data looks like this:
Every 600 ms (at slower BAUD-Raten every 1200 ms) MWS 6 transmits a data
record which starts with time and date. Separated by comma, the single measured
values with sensor identification come in the following order:
Temperature (TE), barometer (DR), humidity (FE), leaf humidity (BF), rain/
precipitation (RE), solar energy (SO), wind speed (WG), wind peak value (WS),
average wind value (WD), wind direction (WR), prevailing wind direction (WV),
ultraviolet radiation (UV), radioactivity (AT), thunderstorm (GE), additional sensor
1 (ZA), additional sensor 2 (ZB), additional sensor 3 (ZC).
If necessary, this identification can be changed. If so, you must also change the
ASCII-File "MWS2_SET.DAT" accordingly. (For information, please see
"MWS2_SET.DOK")
By default, the data are transmitted with 9600BAUD, 8bit, no parity and a Stopbit.
On harddisk, a data file is created every month with a format which is similar to that
of the transmitted data. The data files receive the extension .MWS.
Example : The file of June 96 is called 06_96.MWS.
MWS 6-software needs a computer with at least SX-386 processor 4MB RAM
memory (2MB of which must be free (XMS).
You need a free COM-Port (COM1 or COM2, with Windows-versions COM3 or
COM4 as well).
If you use COM3 or COM4, please note that it is only possible to switch interrupts
for COM3 and COM4 with special interface boards! If you do not have such a board,
there will be problems if you use devices at the same time on COM2 and COM4 or
COM1 and COM3, because the interfaces use the same interrupts by default.
COM3 and COM4 are only available with the WINDOWS-version!
We recommend a mouse (MS-compatible).
For further hard- and software bases, please do see the README - File(s)!!
-
MS-DOS Vers. 4.0 and later
-
HIMEM.SYS
Driver in CONFIG.SYS
-
FILES = 30
Entry in CONFIG.SYS (30 at least)
-
if necessary no EMM386.EXE; if absolutely necessary with extension
call RAM (DEVICE = EMM386.EXE RAM in CONFIG.SYS)
-
Minimum 1.6MB free XMS-memory
If you have installed SMARTDRIVE, you must limit its memory demand. You do this
by changing the respective line in AUTOEXEC.BAT:
C:\DOS\SMARTDRV.EXE /X...
change for
C:\DOS\SMARTDRV.EXE 1500 /X...
Limitation to 1500kB is recommended with 4MB main memory; if there are 8MB and
more a limitation to 4 MB will be sufficient.
If the memory for SMARTDRV is not limited MWS 6-software may abort under
certain circumstances with the error message RAM full and the computer may crash.
Using the F1-key or the "?" in the menu bar, you can call the Online-Help at any time.
Hardware Basis
System requirements
for DOS-versions
SMARTDRIVE