Manual MWS 55 / MWS 88 / MWS 10 and Sensors 55
4.4.3 WEB-Server
To use the station as WEB-server, the HTTP protocol needs to be enabled (see !DC or ?DC, Bit 24).
Um die Station als Web-Server zu benutzen, muss das HTTP-Protokoll freigeschaltet sein
(see !DC or ?DC, Bit 24)
and the Ethernet port must be enabled (
!F+24
or
*ADMIN SET PERMIT 15 ON
) or being con-
figured.
It is important that at the access permissions with *
ADMIN SET INCLUDE
the connection
type HTTP (or HTTP* for privileged access) is added. Access from an IP / MAC address not being
enabled for this connection type will get no answer!
A HTTP read access may be granted with the command
*ADMIN SET INCLUDE 192.168.0.12
[HTTP]
.
If the station hasn't got an internal SD-card, via the HTTP port 80 an internal default page can
be retrieved from the stations IP-address (set by
*ADMIN ETHERNET IP
).