Weather  Station  is  used  for  measuring  temperature, 
humidity,  wind  &  rain  properties  and  sending  the 
measurement values to your Z-Wave network. 
The Weather Station can measure 10 different values: two 
sets  of  temperature/humidity  sensors,  wing  gauge  with  5 
sensors  (direction,  velocity,  wind  gust,  temperature  and 
wind chill) and a rain sensor. With the use of the included 
Weather  Station  USB  KEY  all  10  values  (end  points)  are 
sent and rendered in your home Z-Wave network. 
Qubino Weather Station Key is used for receiving Wireless 
data packages (from Thermo/ Hygro Sensor Ch1, Thermo/ 
Hygro Sensor Ch2, Rain Gauge, Wind Gauge) and  sends 
it to the Z-Wave Controller.   
The  Key  is  designed  to  be  plugged  into  the  USB  Power 
Adapter.  Module  receives  data  for  Temperature,  Wind 
Chill,  Velocity,  Wind  Gust,  Wind  Direction,  Humidity,  Rain 
Rate and Battery Level for each Sensor.  
It is designed to act as repeater in order to improve range 

and stability of Z-wave network

.

 

Package contents: 

 

Weather Station USB Key

 

 

2 x Thermo-Hygro Sensor

 

 

Anemometer (Wind Sensor with Solar panel)  
- Wind cups 
- Wind vane 
- Anemometer arm 
- Anemometer base 
- 4 screws 

 

Rain Sensor 
- Funnel shaped lid with battery hatch 
- Sensor base 
- Bucket see-saw mechanism 
- Protective screen 

4 screws 

Weather Station USB Key 

Installation  

 

Connect  the  Weather  Station  Key  into  the  USB 
Power Supply. 

 

Locate the module far from metal elements.  

 

Locate  the  module  in  the  range  of  Z-Wave  Network 
and in the range of all 433 MHz sensors.

 

 

 

 
 

 

 

 

 

 
S

 

Service button (used to add or remove module 
from the Z-Wave network). 

LED 

LED Blinking Meaning

 

LED is 1 second ON and 1 second OFF 
The module is in exclusion mode 
LED is ON 
The module is in inclusion mode 
LED Blinks 1 time fast 
The module received data from Thermo/Hygro Sensor Ch1 
LED Blinks 2 time fast 
The module received data from Thermo/Hygro Sensor Ch2 
LED Blinks 3 time fast 
The module received data from Wind Sensor 
LED Blinks 4 time fast 
The module received data from Rain Sensor

 

Module 

Inclusion  (Adding  to  Z-Wave 

network) 

 

Connect module to USB Power Supply  

 

auto-inclusion  (works  for  about  5  seconds  after 
connected to power supply) or 

 

enable add/remove mode on main controller 

 

hold service button 

S

 between 1.5 and 4 seconds 

 

NOTE:  For  auto-inclusion  procedure,  first  set  main 
controller into inclusion mode and then connect module to 
USB power supply. 

 

Module Exclusion/Reset (Removing from 
Z-Wave network) 

 

Connect module to power supply 

 

enable add/remove mode on main controller, 

 

hold  service  button 

S

  between  4  seconds  and  8 

seconds 

By  this  function,  all  parameters  of  the  module  are  set  to   
default  values,  own  ID  is  deleted  and  the  module  will 
include as unsecure next time. 
If  service  button  S  hold  more  than  1.5  and  less  than  4 
seconds module is excluded, but configuration parameters 
are  not  set  to  default  values  and  the  module  will  include 
next  time  as  it  was  set  into  the  Configuration  Parameter 
250. 

Association

 

Association  enables  Weather  Station  module  to  transfer 
commands  inside  Z-Wave  network  directly  (without  main 
controller) to other Z-Wave modules.

 

Associated Groups

Group  1:

 

Lifeline  group  (reserved  for  communication  with 

the main controller), one node allowed. 
Group 2: basic on/off (triggered when the Wind Gust of the 
Wind Gauge exceed the Configuration Parameter 1 Value) 
up to 16 nodes. 
Group 3: basic on/off (triggered when the Rain rate exceed 
the Configuration Parameter 2 Value) up to 16 nodes. 

Endpoint 1: Thermo/ Hygro Sensor Ch1 

– Temperature 

Group 1: Lifeline group, 0 nodes allowed. 
Endpoint  1  receives  Temperature  data  from  Thermo/ 
Hygro Sensor on Channel 1. It is capable of receiving data 
in  range  of  -199.0  °C  and  199.0  °C.  However,  the 
operating  temperature  of the  433  MHz  sensor  is from  -10 
°C to 60 °C. 

Endpoint 2: Wind Gauge 

– Direction

 

Group 1: Lifeline group, 0 nodes allowed. 
Endpoint 2 receives Direction data from Wind Gauge. The 
data is in range of 0.0° to 360.0°. 

Endpoint 3: Wind Gauge 

– Velocity 

Group 1: Lifeline group, 0 nodes allowed. 
Endpoint 3 receives wind speed data from Wind Gauge. It 
is capable of receiving data in range of 0.00 m/s to 88.00 
m/s.  

End point 4: Wind Gauge 

– Wind gust 

Group 1: Lifeline group, 0 nodes allowed. 
Group 2: basic on/off (triggered when the Velocity exceed 
the Value of Configuration Parameter 1) up to 16 nodes. 
Endpoint 4 receives wind speed data from Wind Gauge. It 
is capable of receiving data in range of 0.00 m/s to 88.00 
m/s.  

End point 5: Wind Gauge 

– Temperature 

Group 1: Lifeline group, 0 nodes allowed. 
Endpoint  5  receives  Temperature  data  from  Wind  Gauge. 
It  is  capable  of  receiving  data  in  range  of  -199.0  °C  and 
199.0  °C.  However,  the  operating  temperature  of  the 
sensor is from -10 °C to 60 °C. 

End point 6: Wind Gauge 

– Wind Chill 

Group 1: Lifeline group, 0 nodes allowed. 
Endpoint  6  receives  Temperature  data  from  Wind  Gauge. 
It  is  capable  of  receiving  data  in  range  of  -199.0  °C  and 
199.0  °C.  However,  the  operating  temperature  of  the 
sensor is from -10 °C to 60 °C. 

End point 7: Rain Sensor 

Group 1: Lifeline group, 0 nodes allowed. 
Group 2: basic on/off (triggered when the Rain rate exceed 
the Configuration Parameter Value 2) up to 16 nodes. 
Endpoint 7 receives and calculates rain rate. The rain rate 
is in range of 0.00 mm/h and 300.00 mm/h. 

End point 8: Thermo/ Hygro Sensor Ch1 

– Humidity  

Group 1: Lifeline group, 0 nodes allowed. 
Endpoint  8  receives  Humidity  data  from  Thermo/  Hygro 
Sensor  on  Channel  1.  The  data  is  in  range  of  0%  and 
100%. 

End  point  9:  Thermo/  Hygro  Sensor  Ch2 

– 

Temperature  

Group 1: Lifeline group, 0 nodes allowed. 
Endpoint  9  receives  Temperature  data  from  Thermo/ 
Hygro Sensor on Channel 2. It is capable of receiving data 
in  range  of  -199.0  °C  and  199.0  °C.  However,  the 
operating  temperature  of  the  sensor  is  from  -10  °C  to  60 
°C. 

End point 10: Thermo/ Hygro Sensor Ch2 

– Humidity  

Group 1: Lifeline group, 0 nodes allowed. 
Endpoint  10  receives  Humidity  data  from  Thermo/  Hygro 
Sensor  on  Channel  2.  The  data  is  in  range  of  0%  and 
100%. 

Configuration parameters 

Parameter No. 1 

– Wind Gauge, Wind Gust Top Value

 

Available configuration parameter (data type is 2 Byte 
Dec): 

 

default value 1000 (10,00 m/s) 

 

– 8800 = value from 0.00 m/s to 88.00 m/s -  

if the Wind Gust is Higher than the Parameter Value, 
a device triggers an Association.  

Parameter No. 2 

– Rain Gauge, Rain Rate Top Value

 

Available configuration parameter (data type is 2 Byte 
Dec): 

 

default value 200 (2,00 mm/h) 

 

– 30000 = value from 0.00 mm/h to 300.00 mm/h - 

if the Sensor Rain Rate is Higher than the Parameter 
Value, a device triggers an Association  

Parameter No. 3 

– Wind Gauge, Wind Gust

 

Available configuration parameter (data type is 1 Byte 
Dec): 

 

default Value 1 

 

0 - If the Wind Gust is Higher than the Parameter No. 
1 Value, then a Device sends Basic Set = 0x00.  

 

1

 

- If the Wind Gust is Higher than the Parameter No. 

1 Value, then a Device sends Basic Set = 0xFF.) 

Parameter No. 4 

– Rain Gauge, Rain Rate

 

Available configuration parameter (data type is 1 Byte 
Dec): 

 

default Value 1 

 

0  -  If  the  Rain  amount  is  Higher  than  the  Parameter 
No. 2 Value, then a Device sends Basic Set = 0x00.  

 

1  -  If  the  Rain  amount  is  Higher  than  the  Parameter 
No. 2 Value, then a Device sends Basic Set = 0xFF.) 

Unsolicited Report 

If  you  enable  Unsolicited  Reports  on  the  End  Points,  the 
USB  Key  will  send  data  to  the  controller  every  time  it 
receives  data  from  the  433MHz  sensors,  which  are 
different from the precious data. 

  

Parameter No. 5 

– End point 1 – Unsolicited Report

 

Available configuration parameter (data type is 1 Byte 
Dec): 

 

default Value 1 

 

– Unsolicited Report disabled  

 

– Unsolicited Report enabled 

  

Parameter No. 6 

– End point 2 – Unsolicited Report

 

Available configuration parameter (data type is 1 Byte 
Dec): 

 

default Value 1 

 

– Unsolicited Report disabled  

 

– Unsolicited Report enabled 

  

Parameter No. 7 

– End point 3 – Unsolicited Report

 

Available configuration parameter (data type is 1 Byte 
Dec): 

 

default Value 1 

 

– Unsolicited Report disabled  

 

– Unsolicited Report enabled 

  

Parameter No. 8 

– End point 4 – Unsolicited Report

 

Available configuration parameter (data type is 1 Byte 
Dec): 

 

default Value 1 

 

– Unsolicited Report disabled 

 

– Unsolicited Report enabled 

  

Parameter No. 9 

– End point 5 – Unsolicited Report

 

Available configuration parameter (data type is 1 Byte 
Dec): 

 

default Value 1 

 

– Unsolicited Report disabled 

 

– Unsolicited Report enabled 

  

Parameter No. 10 

– End point 6 – Unsolicited Report

 

Available configuration parameter (data type is 1 Byte 
Dec): 

 

default Value 1 

 

– Unsolicited Report disabled  

 

– Unsolicited Report enabled 

  

Parameter No. 11 

– End point 7 – Unsolicited Report

 

Available configuration parameter (data type is 1 Byte 
Dec): 

 

default Value 1 

 

– Unsolicited Report disabled  

 

– Unsolicited Report enabled 

  

Parameter No. 12 

– End point 8 – Unsolicited Report

 

Available configuration parameter (data type is 1 Byte 
Dec): 

 

default Value 1 

 

– Unsolicited Report disabled  

 

– Unsolicited Report enabled 

  

Parameter No. 13 

– End point 9 – Unsolicited Report

 

Available configuration parameter (data type is 1 Byte 
Dec): 

 

default Value 1 

 

– Unsolicited Report disabled  

 

– Unsolicited Report enabled 

  

Parameter No. 14 

– End point 10 – Unsolicited Report

 

Available configuration parameter (data type is 1 Byte 
Dec): 

 

default Value 1 

 

– Unsolicited Report disabled 

 

– Unsolicited Report enabled 

  

Parameter No. 15 

– Random ID Enable

 

Available configuration parameter (data type is 1 Byte 
Dec): 

 

default Value 0 

 

– Random ID disabled  

 

– Random ID enabled 

If  Random  ID  is  disabled,  the  Weather  Station  USB  Key 
can  receive  data  from  multiple  433  MHz  Sensors  on  the 
same Channel. If the Random ID is enabled, the USB Key 
can  receive  data  from  only  one  sensor  on  the  same 
channel.  If  the  USB  Key  does  not  receive  a  data  from  a 
sensor  on  a  specific  channel  for  more  than  2.5  hours,  it 
clears the Random ID of the device and waits for a new ID. 
If you replace the batteries in the modules, the Random ID 
will change. If you want that the USB Key accept a module 
immediately,  set  the  Parameter  No.  15  to  “0”  and  in  the 
next step again to “1”. 

  

Parameter No. 250 

– Unsecure / Secure Inclusion

 

Available configuration parameter (data type is 1 Byte 
Dec): 

 

default Value 0 

 

– Unsecure Inclusion 

 

– Secure Inclusion 

The  Weather  Station  Key  supports  both,  the  secure  and 
unsecure inclusion. Even if the controller does not support 
security  command  classes,  the  Key  could  be  included  as 
unsecure 

and 

keep 

all 

the 

functionality. 

By  default,  the  Key  includes  as  unsecure.  To  include  the 
Key as secure follow the procedure: 
1. 

Include the Key into the controller 

2. 

Set the parameter 250 to the value “1” 

3. 

Enable add/remove mode on main controller, 

4. 

Hold  service  button  S  between  1.5  and  4  seconds 
to exclude the module 

5. 

If  the  exclusion  of  the  module  was  successful,  the 
LED on the module starts blinking 

6. 

Unplug the module out of the power supply 

7. 

enable add/remove mode on main controller 

8. 

Plug the module into the power supply to star auto-
inclusion 

9. 

Now the module should be included as secure 

The same procedure is to include the module as unsecure. 

Safety Procedure 

I

n  the  case  of  lost  connection  between  the  433  MHz 

Wireless Sensor and the Weather Station USB Key (more 
than  15  minutes  of  lost  connection),  the  module  will  set 
Sensor values to extreme values. (Temperature = 
-199.0  °C,  Velocity  =  88.00  m/s,  Rain  =  300.00  mm/h, 
Humidity  =  100  %  or  Direction  =  0.0°),  so  that  the 
associations  and  scenarios  are  triggered  to  lower  the 
chance of potential damage. 
If the Weather Station USB Key lose the power supply (or 
any  other  reason  reset  the  Key),  the  Key  will  not  report 
Sensor  Values  to  the  controller  until  new  data  is  received 
or  maximum  240  seconds.  If  after  240  seconds,  the  Key 
still does not have new data from the sensor, it will set the 
sensor values to extreme values. 
On  each  End  point  we  can  get  battery  level  from 
corresponding  sensor.  On  the  Root  device  is  a  battery 
level from the sensor with the lowest battery level. 

Technical Specifications    