background image

5

PORTA

DAVIT

  QUANTUM

Temperature Range

This product can be operated in ambient dry 
temperatures between –20°C and +55°C (-4°F 
and 131°F). Consult your supplier in case of 
extreme working conditions. If used in sub-
zero and wet conditions, fall arrest appliances 
characteristics may change.

Notes for Correct Operation 

   

 For winched variants, each of the product’s 
three sheaves have been designed to work 
specifically with the rope materials and 
diameters detailed below:

   

 

It is important to ensure that the correct 
sheave is being used to prevent pinching or 
squashing of the rope

   

 

We recommend the use of load-sensing or 
overload protection devices on all lifts 

   

 

The risk assessment and method statement 
must consider any factors that might apply 
additional loading to the system during lifting 
operations

   

 

Suitable, appropriately rated winches and 
connection plates must be used for all 
applications

   

 

Take care when transporting and storing the 
system to avoid damage 

   

 

Assemble only as instructed (ensure all 
bolts are present and fitted correctly as per 
instructions 

   

 

We recommend that gloves are worn when 
using the equipment

   

 

Attach the hoist to the dedicated lifting point 
only, making sure it is attached in a way that 
does not expose the user to danger by the 
hoist, chain or load

   

 

Do not allow the load to swing

   

 

Only attach the load to the lifting points on the 
head or winch line

   

 

Contact your supplier before using the davit 
in (special atmospheres) extreme conditions

   

 

To avoid side pull, lowering and lifting should 
only be carried out when the load chain forms 
a straight and vertical line between the load 
and lifting attachment point. (Refer to figure A)

   

 

Do not assemble the davit in any non-
approved socket

   

 

Make sure that the kingpin shaft is correctly 
seated in the socket before use

   

 

Do not use this product if it does not rotate 
freely in the bearing or if the bottom flange 
is fouled in any way that prevents that free 
rotation

   

 

Do not knot or shorten the tension strap to 
reduce the operating radius

   

 

Always ensure that the product is set up in 
its mounting socket in a safe location where 
there is no risk of falling into the hazard or lift 
area

Intended Use

This product is intended to be used for; the lifting 
of goods, the lifting of personnel, rope access, or 
providing a safety anchor for the prevention of falls.

It is expected that all users of this product have the 
necessary medical and physical capabilities, are fully 
trained and competent in its safe assembly and use. 

Inspection Prior to Initial Operation

Each product must be inspected prior to initial 

operation by a competent person to ensure that the 

structure is safe and that it has not been damaged 

by incorrect assembly, transport or storage. 

Inspection Before Starting Work

Before starting work, the product assembly and 
all load-bearing components should be checked 
for visual defects as per the inspection checklist on 
page 8.

Correct Operation

Maximum Capacity

Goods Lifting:

 This product is designed to lift 

and lower loads up to its rated capacity. Do not 
exceed the capacity indicated on the product.  

Personnel Lifting: 

When lifting people, the 

overall load limit is reduced by half to provide an 
increased safety factor.  The maximum capacity 
permitted by the personnel winch/accessory used 
in conjunction with the product also needs to be 
taken into account. 

Only chain hoists with a capacity of up to 1000kg 
are suitable for this davit. The structure has been 
designed to take into account the weight of 
a standard chain block but, if a device with a 
significant additional weight is being used, then 
this needs to be included within the overall 
capacity. Care should also be taken when using 
any lifting device other than a manual chain 
hoist in case the dynamic effects of this reduce 
the overall capacity of the davit. REID Lifting’s 
representatives can provide additional advice on 
this if required.  

The table below gives the maximum WLL and 
radius for each of the standard models.

Please be aware that the maximum radius 
is achieved when the davit is being used at 
approximately 75% of its maximum capacity.

Sheave Colour

Rope Diameter

Rope Material

Yellow

4mm - 5mm

Wire rope / Fibre rope

White/Natural

4mm - 7mm

Wire rope / Fibre rope

Grey

8mm - 12mm

Fibre rope only

Max. Goods WLL

Max. Personnel WLL

Max. Radius

PDQ 1  

(PDQ600)

600kg

300kg

1200mm

PDQ 2  

(PDQ500)

500kg

250kg

1500mm

A

Содержание PORTADAVIT QUANTUM PDQ 1

Страница 1: ...REIDLIFTING COM PORTADAVIT QUANTUM Assembly Operation Guide ...

Страница 2: ...27 Lightweight Portable Safe Please read the following instructions and guidance notes carefully before using or operating the system They contain important information about how to handle and use the system in a safe and efficient way avoiding danger reducing repair costs and downtime and increasing the reliability and lifespan of the system They apply for Operation including preparation troubles...

Страница 3: ... safe location where there is no risk of falling into the hazard or lift area Intended Use This product is intended to be used for the lifting of goods the lifting of personnel rope access or providing a safety anchor for the prevention of falls It is expected that all users of this product have the necessary medical and physical capabilities are fully trained and competent in its safe assembly an...

Страница 4: ...a fall arrest system which is only as strong as the lowest rated component Each lift must be properly planned and all weights clearly known along with the WLL and constraints of all fall arrest system devices Additional Notes for Correct Operation Ensure suitable and appropriately rated winches and connection plates are used for all applications Never walk away from the structure whilst connected ...

Страница 5: ...is no wear or elongation on the bolt holes and ensuring that the jib section retracts smoothly Any necessary repairs should only be carried out by an approved specialist workshop using original spare parts It is recommended that once inspected or repaired the device is marked with the date of the next inspection Inspections are instigated by the user If detailed information is required on inspecti...

Страница 6: ... more than 3 degrees from the horizontal Note Site specific information regarding the installation of REID davit sockets CANNOT be detailed within this operating manual as each site structure is different A qualified engineer MUST design and approve each installation based on the minimum mounting requirements site information and experience Minimum Mounting Requirements The supporting structure an...

Страница 7: ...additional instructions should be followed Inspections must be instigated by the user prior to each use if used in a potentially explosive atmosphere Inspections and maintenance must be carried out at a safe distance away from an explosive atmosphere ATEX This product has been designed for use in explosive atmospheres in line with the following requirements and information Any use which differs or...

Страница 8: ...f a socket extension is optional and the socket type may vary between a Top Mount Side Mount Bridge Mount Cast In or Resin Bonded depending on application Appropriate PPE should be worn Gloves Protective Footwear Hard Hat Assembly Instructions Strop Column Restraint Point Kingpin Radius Adjustment Plates and Pin Head Lower Jib Carry Handle Connection Channel Telescopic Jib Pin Upper Jib Innovative...

Страница 9: ...n Appropriate PPE should be worn Gloves Protective Footwear Hard Hat Assembly Instructions Caution Potential finger trap Assembling the PORTA DAVIT QUANTUM Type W Winched Column Restraint Point Kingpin Sheave Bracket Assembly Head Lower Jib Carry Handle Harken LokHead Double Winch Bracket Assembly Radius Adjustment Plates and Pin Telescopic Jib Pin Upper Jib Rigid Backstay Sheave Adjustment Handle...

Страница 10: ...the radius values with the upper value stating the outer shackle position and the lower value stating the inner shackle position The operating dimensions can be found on page 19 PORTADAVIT QUANTUM Variants Options Assembly Instructions Ensure the radius adjustment pin is fully engaged before use Adjusting the Radius 19 7 7a ...

Страница 11: ...e front shackles in the head of the davit to support the rotation The rotation should be done in a controlled manner When the rotational handle is attached to the Davit the following points must be observed Attach the rotational handle to the column of the Davit at a suitable height Ideal position should be around hip height Secure in place with the pins provided See Figure 1 Rotate the handle upw...

Страница 12: ... to inner shackle A B C D E A B C E D C E D B A C B A E D A E B C D Winched 296mm Radius Adjustment Points Dimensions mm Part Number WLL A B C D E PDQ1S 600KG 1 2007 1935 1799 1200 1100 2 2061 1989 1848 1100 1000 PDQ1W 3 2111 2039 1892 1000 900 PDQ2S 500KG 1 1837 1766 1647 1500 1400 2 1899 1827 1703 1400 1300 PDQ2W 3 1957 1885 1755 1300 1200 Radii achieved at 75 WLL 1680mm ...

Страница 13: ... the IRATA Code of Practice and in doing so contributes to promote the development of safe systems Conformité Européenne CE UK Conformity Assessed UKCA REID Lifting s products have been designed tested and approved as appropriate by the Conformité Européenne and UK Conformity Assessed This certifies that REID Lifting s products meet the demands of the European and UK Directives and Regulations reg...

Страница 14: ...engage before loading the system Insert the clevis pin and secure with the clip before loading the system Restraint point only Read the operational manuals before using the system Ensure the pin is fully engaged 1 Product Number 2 Serial Number 3 WLL 4 Year of Manufacture 5 Standards 6 ATEX 7 Max Moment The system is not suitable for fall arrest applications The system is suitable for fall arrest ...

Страница 15: ...r The goods capacity WLL of the device The year of manufacture The standards to which the device is approved The ATEX rating of the product if applicable CE Marking Minimum braking load MBL Insert data from serial numbers found on product into table here Periodic Examination Repair History 29 PORTADAVIT QUANTUM Product Identification Inspection Record Notes ...

Страница 16: ...31 PORTADAVIT QUANTUM Notes Notes ...

Страница 17: ...om www reidlifting com Printed using environment friendly processes and materials All information herein is copyright protected by REID Lifting Ltd All company and product names are Trade Mark and Trade Name protected and all REID Lifting Ltd Product IPR is protected under Patents Patents Pending and or Design Rights Contact Us PDQ O M EN V5 08 2022 ...

Отзывы: