Function description
50
9
Error memory
Error message display
Number of errors
Error text
Welding time
Operating time
10 Indicating symbol
The
REMOTE CONTROL
AKTIVE symbol [
BF17
]appears on the
right of the status line [
BF9
] and indicates the remote controller as
active.
The control lamp BETRIEB Symbol [
BF16
] in green indicates that
there is an open circuit voltage at the torch or electrode holder.
The display is on the left in the status line.
The same display in red indicates an overtemperature fault.
The power section is switched off and there is no output voltage as
long as this symbol is displayed. With TIG welding the gas post flow
time runs when the power section is switched off. Once the unit has
cooled the LED goes out and welding can commence automatically.