background image

 

EC-Declaration of Conformity 

for following listed products

 

Focus.Arc P 450 WS

1307088 Focus.Arc P 350 W

1307066

Focus.Arc P 450 S

1307087 Focus.Arc P 350 

1307065

Focus.Arc P 450 W

1307086 Focus.Arc P 300 WS

1307058

Focus.Arc P 450

1307085 Focus.Arc P 300 S

1307057

Focus.Arc P 400 WS

1307078 Focus.Arc P 300 W

1307056

Focus.Arc P 400 S

1307077 Focus.Arc P 300

1307055

Focus.Arc P 400 W

1307076 Focus.Arc P 250 WS

1307048

Focus.Arc P 400

1307075 Focus.Arc P 250 S

1307047

Focus.Arc P 350 WS

1307068 Focus.Arc P 250 W

1307046

Focus.Arc P 350 S

1307067 Focus.Arc P 250

1307045

Focus.Arc S 450 WS

1330234 Focus.Arc S 450 W

1330214

Focus.Arc S 400 WS

1330233 Focus.Arc S 400 W

1330213

Focus.Arc S 350 WS

1330232 Focus.Arc S 350 W

1330212

Mega.Arc P 450 WS

1307188 Mega.Arc S 450 WS

1330408

Mega.Arc P 450 W

1307186 Mega.Arc S 450 W

1339406

Mega.Arc P 450 S

1307187 Mega.Arc S 450 S

1330407

Mega.Arc P 450

1307185 Mega.Arc S 450

1330405

Mega.Arc P 400 WS

1307178 Mega.Arc S 400 WS

1330398

Mega.Arc P 400 W

1307176 Mega.Arc S 400 W

1330396

Mega.Arc P 400 S

1307177 Mega.Arc S 400 S

1330397

Mega.Arc P 400

1307175 Mega.Arc S 400

1330395

Mega.Arc P 350 WS

1307168 Mega.Arc S 350 WS

1330388

Mega.Arc P 350 W

1307166 Mega.Arc S 350 W

1330386

Mega.Arc P 350 S

1307167 Mega.Arc S 350 S

1330387

Mega.Arc P 350 

1307165 Mega.Arc S 350 

1330385

Mega.Arc P 300 WS

1307158 Mega.Arc S 300 WS

1330378

Mega.Arc P 300 W

1307156 Mega.Arc S 300 W

1330376

Mega.Arc P 300 S

1307157 Mega.Arc S 300 S

1330377

Mega.Arc P 300

1307155 Mega.Arc S 300

1330375

Содержание 1307045

Страница 1: ...CUS ARC P and S MEGA ARC P and S Short Manual This short manual does not substitute the original operator manual Please read this document carefully before your start operating the welding power sourc...

Страница 2: ...ed or put out of operation as this poses a risk and the intended use of the system is no longer guaran teed Dismantling of safety devices when setting up repairing and maintaining is specially describ...

Страница 3: ...ipotential bonding as well as the assessment of the environment such as computers control equipment sound and television broadcast transmitters neighboring Persons e g when using a pacemaker The user...

Страница 4: ...is obliged to provide the operator with the necessary PPE Intended Use The MIG MAG welding systems are only to be used for MIG MAG or manual electrode welding for hand guided and machine guided opera...

Страница 5: ...2 Device structure and connectors Compact machine power source with sepated S wire feeder unit Rear of Compact machine Separate wire feeder unit...

Страница 6: ...crew cap 12 Window level coolant 13 Crane eyes on the trolley 14 Option not installed 15 Shielding gas connection for welding torch 16 Mains cable CEKON 16 32A 4 wire connection 17 Feed range on the c...

Страница 7: ...F6 AF4 AF3 AF2 Display Indication and Adjustment field BF1 BF10 Display Total Overview BF11 Submenu button BF12 Home button BF13 Return button Corner Menu s BF14 left top corner BF15 right top corner...

Страница 8: ...g MIG MAG welding by hand Manual mode Stick welding BF2 Corner Menu Operating Mode 2 Tact 2 step mode 2 Tact with ramp down 4 Tact 4 step mode 4 Tact with ramp down Dot welding Dot welding with ramp d...

Страница 9: ...Process Power Arc Focus Arcs Power Puls Focus Puls Focus Root Root BF5 Indicate and adjust welding current BF6 Indication of arc voltage Indicate and adjust in method MIG MAG Hand BF7 Indicate and ad...

Страница 10: ...LBL correction 9 9 9 9V Korrekturwert Lichtbogenl nge Time Ignition current 0 5 0sec Current I1 0 5 0sec Absenkzeit IHotstart nach ISchwei en SDI I1 5 0 5 0 LBL correction I1 9 9 9 9V Pulse time t1 0...

Страница 11: ...nfirm by pushing rotary encoder insert name with keyboard on the screen Confirm Rename Folder Place cursor on the selected folder press Edit insert new name Confirm Move Folder Place cursor on the sel...

Страница 12: ...g the encoder The active fields Current Material VD LBL and SDI are adjustable if there is no lock function key switch active Copy Job JSelect Copy Job confirm place cursor on the job to be copied con...

Страница 13: ...ve Active for dt HOLD Indictes the latest welding values when torch button is released Time HOLD active time sec Mode of LBL correction U dV leading value is voltage or wire speed Adjustment of weldin...

Страница 14: ...mbol Despriction Functionality BF22 Setup Setup Parameter Adjust ment Desription Factory Settings All values in the Setup menu will be set to factory default values Jobs are not included and stay unch...

Страница 15: ...omania Russia Turkey Chinese AF1 Indication field 1 general use AF2 Indicates active welding characteristic AF3 Indication field 2 general use AF4 Indicates active welding arc if color is black no sig...

Страница 16: ...ng Method choose MSG Manuell Get out by BF3 Welding Characteristic choose a different characteristic Screen in this mode Changable values are voltage and wire feeding speed It is poissible to save the...

Страница 17: ...ht All values for increase of output current Iout an the welding current I1 are limited by the power class of the inverter 250A 450A Hotstart 10 200 from setpoint of current I1 ignition current Formul...

Страница 18: ...4 Tact with ramp down 2 Tact Dot welding 2 Tact Dot with ramp down 2 Tact Interval 2 Tact Interval with ramp down 4 Tact Interval 4 Tact Interval with ramp down Process Power Arc Focus Arc Power Pulse...

Страница 19: ...L Correction Welding circuit adjustment Automatic Welding circuit adjustment Inductivity Welding circuit adjustment Impedan ce Up Down Standby mode Up Down Welding mode Up Down Speed factory settings...

Страница 20: ...dated The update files have the following names and could be used for all power classes TYP_250 450A_BDE V01_00_47_32 extension Software User inteface BDE TYP_250 450A_ST V01_02_00_00 extension Softwa...

Страница 21: ...e of Rehm you will find the newest files and characteristics but the APP is downloading the files automatic after connecting to the welding machine Indication field AF5 shows if WLAN in the machine is...

Страница 22: ...eally important to understand that machine switches to boot mode during update It is impossible to weld in boot mode When updating UI the screen gets dark without any signs on it Don t switch off the...

Страница 23: ...ard ST ca 5 min Motor driver board MK ca 2 min User Interface DBE ca 20 min Characteristic Group KNG ca 6 min Important please follow the instructions shown on your Smartphone and if requested switch...

Страница 24: ...Voltage is above max input tolerance Check grid voltage 22 Communication error UARTbetween welding control board and power control board Communication between power source and welding control board is...

Страница 25: ...c S 400 W 1330213 Focus Arc S 350 WS 1330232 Focus Arc S 350 W 1330212 Mega Arc P 450 WS 1307188 Mega Arc S 450 WS 1330408 Mega Arc P 450 W 1307186 Mega Arc S 450 W 1339406 Mega Arc P 450 S 1307187 Me...

Страница 26: ...above products comply with the requirements of this directive and comply with the safety requirements for arc welding units in accordance with the following product standards EN 60 974 1 2018 12 Arc...

Страница 27: ......

Страница 28: ...anks to this central organization and our forward looking commitment new findings can quickly flow into production The wishes and demands of our customers form the basis for a progressive one Product...

Отзывы: