background image

3

RAUTOOL A-LIGHT2

SAFETY INFORMATION

General Use and Care

– The tool is intended to be used with REHAU 

SDR11 

compression-

sleeve 

fittings

 in the

 

size range 25 to 40 mm. Do not use the tool for 

other purposes.

– Only operate the tool with original REHAU parts and accessories.
– Maintenance and repair work should be done only in a service cen-

ter authorized by REHAU. We will not be responsible for any work

 

performed by an unauthorized person.

– Keep the tool, the batteries and the charger away from moisture,

 

extreme heat, oil and solvents. The charger is only intended for use

 

in dry, indoor rooms. It must not be used outdoors.

– Before use, examine the tool and accessories for damage or

 

defects 

(for example, cracks in the cable insulation, oil leaks from

 

the tool, 

bent compression cylinders, damage or visible wear of the

 

jaw sets). 

Check whether the moving parts are in proper working

 

order, that 

they are not jammed and that parts are not damaged. All

 

parts must 

be correctly assembled and satisfy all of the conditions

 

to ensure 

proper tool operation.

– Never work with a damaged tool or accessory. Immediately send

 

the damaged tool to your local REHAU representative

– At every tool change (replacement of jaw sets), remove the battery

 

from the tool to prevent unintended activation.

– When charging, only use one-phase alternating current at the volt-

age indicated on the power rating label. 

NOTICE

To avoid damage to tool, always follow all operating

instructions

– To prevent the motor from overheating, do not operate at maximum

pressure for any prolonged period. The tool is not suited for long-
term use. After about 50 consecutive compressions, it should be
allowed to rest for at least 15 minutes to allow it to cool.

– To avoid damage to the tool, do not insert foreign objects into the

ventilation grills on the charger.

– REHAU will not accept any liability for damage or injury attributable

to unsafe product use, poor maintenance or improper product and
system usage. For technical information contact your local REHAU
representative or download documents at www.na.rehau.com/
resourcecenter.

Read all safety information and assembly instructions before using the 
tool. Follow these operating instructions and always keep the safety 
warnings with the tool. In addition to the operating instructions, always 
observe generally applicable statutory and other binding regulations 
relating to the prevention of and protection against accidents. 

WARNING!

  Improper use of the tool could cause death or       

serious injury

       CAUTION!

  Improper handling of the tool may result in personal  

        injury and/or damage to the tool.

– Never operate the tool in an environment presenting the risk of

fire or explosion.

– Do not burn the tool, charger or rechargeable batteries. Re-

chargeable batteries may explode and flare up.

– Only use the battery and charger supplied by the OEM. Using a

different battery or different charger may cause an explosion.

– Do not touch moving parts. Touching moving parts could

cause fingers to become trapped.

– Ensure rechargeable battery contacts cannot be shorted by

metal objects, such as screws, instruments, nails, etc. A short

circuit between the battery contacts can cause burns or fire.

– As a result of improper use, liquid can leak from the bat-

tery. Avoid contact with this liquid. In the event of inadvertent
contact, rinse off with water. Should the liquid enter the eyes,
obtain medical assistance immediately.

– Do not wear loosely fitting clothes or jewelry. They may get

caught in moving parts. Wear a hair net if you have long hair.

– Do not work below the minimum processing temperature of

14°F (-10°C). Processing at temperatures under 14°F (-10°C)

or over 113°F (45°C) may result in damage to jointing

components, to the tool and/or in personal injury.

– At lower temperatures (below 32°F [0°C]) it is recommended

that the jointing components be stored in a warm environment
before being processed.

Содержание RAUTOOL A-LIGHT2

Страница 1: ...Construction Automotive Industry www rehau com RAUTOOL A LIGHT2 PRODUCT INSTRUCTIONS...

Страница 2: ...11 Important Notes 13 Maintenance 14 Troubleshooting 15 RAUTOOL A LIGHT2 TABLE OF CONTENTS This symbol and the signal words DANGER WARNING or CAUTION alert you to personal injury hazards If you don t...

Страница 3: ...iability for damage or injury attributable to unsafe product use poor maintenance or improper product and system usage For technical information contact your local REHAU representative or download doc...

Страница 4: ...139592 Expander bit RO 25 32 mm Art 247504 001 Expansion head RO 25 x 2 3 mm Art 139662 001 Expansion head RO 32 x 2 9 mm Art 137193 001 Expansion head assembly A light2 40 x 3 7 mm Art 138323 001 Set...

Страница 5: ...No 203619 001 Expander Heads RO Art No 139622 001 25 x 2 3 mm Art No 137193 001 32 x 2 9 mm Clamping Jaws Art No 257259 002 25 32 mm Art No 201801 001 40 mm Expander Bit RO Art No 247504 001 25 32 mm...

Страница 6: ...ight basic tool with battery approx 5 3 lb 2 4 kg Description and Operation Technical data No Tool Elements Function 1 Operating switch Activate the compression process 2 Reset knob Slider for opening...

Страница 7: ...Green LED flashes Charger ready for use Red LED flashes Charging delayed battery cooling Red LED displays a steady light Battery charging charged level less than 80 Green and red LEDs display a stead...

Страница 8: ...2 Hz Battery is flat Service If the LED lights up for 20 sec and then flashes this means that the battery is flat and also that maintenance is due 20 s 5 Hz Overheating If the diode flashes quickly fo...

Страница 9: ...receiving groove of the bit must lie in the compression jaws Before activating the tool check to make sure that the seating and clamping action of the bit in the jaws is correct to avoid falling out...

Страница 10: ...inder 3 By rotating the tool cylinder the compression jaw can be brought into the correct working position 2 Fix the compression jaws with the pins Ensure the identical alignment of the double jaws fo...

Страница 11: ...inside taper must point toward the joint 3a Expansion using expanders Expand pipe rotate 30 and repeat The mininum distance between expander head and compression sleeve must be two compression sleeve...

Страница 12: ...to become trapped The compression process can be interrupted at any time by releasing the operating switch 7 The tool comes equipped with a semi automatic release valve If the tool is moved to its fi...

Страница 13: ...e jaws is correct to avoid falling out CAUTION Do not touch moving parts Touching moving parts could cause fingers to become trapped NOTICE To avoid damage to the tool do not expand the pipe under ben...

Страница 14: ...ir Make sure that the jaw sets are fully applied across the entire surface and at a right angle during the compression process The compression sleeve should be inserted up to the fitting collar Regula...

Страница 15: ...your local REHAU representative Air in the hydraulic system Interrupt the compression process Hold reset knob under tension see page 6 no 2 and at the same time continuously activate the operating swi...

Страница 16: ...ble but no representations guarantees or warranties of any kind are made as to its accuracy suitability for particular applications or the results to be obtained therefrom Before using the user will d...

Отзывы: