1.
Disassemble the wire tightener by removing the plate and the 2x 8mm nuts. Place the lat wire in
the tightener as shown in photo # 2 below (as close to the overhang as possible).
Make sure the
wire adjustment glider is at its lowest position on the number pole when you position the
wire tightener.
2.
Apply the thimble just below the tightener and bring the lat wire around it as shown in photo # 3
above. Wind the wire around the two bolts as a figure eight. This will ensure the wire stays secure
after the nuts are tightened.
3.
Place the cover plate over the two bolts and secure the nuts (8mm) on the two bolts as shown in
photo # 4 above.
Note: Tighten the nuts on the bolts as hard as you can to ensure a secure fit. The plate on top
of the wire should bend in the middle when the nuts are tightened all the way.
4.
Place supplied heat shrink over the wire tightener assembly and shrink it by using a heat
gun or a hair dryer. A finished assembly should resemble photo # 5 below.
At this point the module should be fully operational. Please contact RehabPro, Inc. with
any issue you have either by calling 602-317-7207 or e-mail Kris van Scheers at
Содержание MMS1