6 - Installation and Commissioning

Installation shall meet valid rules and may be done by qualified staff only.

Defects caused by improper installation, use or handling are not covered by warranty.

After  the  tank  is  installed  and  connected  to  an  existing  heating  system,  it  is  recommended  to  clean  the  entire 

 

heatingsystem using a suitable cleaning agent, e.g. BP 400.

Anti-corrosion protective liquid should be also used, e.g. BP 100 Plus.

6.1 - Connection to heat sources

Place the tank on the floor, as close to your heat source as possible. Fit the insulation, cf. Installing Insulation on the 

Tank. Connect the heating system according to the recommended connection layout - see Chap. 5.Install a drain valve 

at the lowest point of the tank. Install an air vent valve at the highest point of the system. Insulate all the connecting 

piping.

6.2 - Connection to a solar thermal system

This thermal store is primarily not designed to be connected to a solar thermal system. However, when needed, such 

 

a connection can be done by means of a heat exchanger between the solar thermal system and the thermal store. In 

such an event, all the connecting piping between the tank and this heat exchanger shall be thoroughly insulated.

6.3 - El. heating element installation

These thermal stores can be equipped with electric heating elements of output up to 12 kW depending on the volume of 

the thermal store - see the table of max. output of heating elements in hot water tanks and thermal stores. They can be 

connected either directly (elements with integrated thermostat) or via the controller of the entire heating system.

All electric heating elements shall be protected by a safety thermostat.

The electric heating element shall be wired by a professionally qualified person only.

6.4 - Commissioning

This tank is not designed for DHW heating.

The tank shall be filled up together with the heating system, respecting valid standards and rules. In order to minimize 

corrosion, special additives for heating systems should be used. The quality of heating water depends on the quality of 

filling water at commissioning, on the top-up water quality and on the frequency of topping up. This has a strong influen

-

ce on the lifetime of heating systems. Poor quality of heating water may cause problems like corrosion or incrustation, 

esp. on heat transfer surfaces.

Fill  the  heating  circuits  with  the  appropriate  fluids  and  air-bleed  the  entire  system.  Check  all  connections  for  leaks 

and verify the system pressure. Set the heating controller in compliance with the documentation and manufacturer’s 

 

recommendations.

Check regularly proper function of all control and adjustment elements.

7 - Installing Insulation on the Tank

Product description

Fleece insulation with a hard polystyrene surface, closed by a quick lock.

Warning

Insulation installation shall be done in two or three persons, depending on its size. The PU leather surface coated fleece 

insulation 

must not be installed at temperatures below 20 °C

. If this cannot be avoided, the insulation shall be pre

-

-warmed in another room to at least 20 °C. It is impossible to install insulation of lower temperature, there is a risk of 

damage.

Do not use any tools for installation.

Keep away from open fire.

Installing insulation

1. Put the bottom insulation under the tank and place the tank following installation instructions.

2. Wrap the insulation around the tank carefully. Check that the insulation adheres to its body perfectly. This can be 

reached by rubbing and patting the insulation by hand from its centre evenly in both directions until the insulation 

adheres to the tank’s surface completely and no bubbles are left.

3. Use the holes for connections as a rest during the insulation installation.

4. At least one person presses the insulation to the tank, pulling both ends together. The other person closes the quick 

lock from the side.

5. Put on the upper insulation and cover.

6. Push on the covering plastic rosettes depending on the size of connections, or put on the flange plug(s) with insulation.

7. Finish the tank installation in compliance with the respective instructions and valid standards and rules.

Содержание PS 1100 K+

Страница 1: ...www regulus eu PS K PS K EN Installation and Operation Manual THERMAL STORES PS 400 K PS 500 K PS 600 K PS 700 K PS 900 K PS 1100 K...

Страница 2: ...surface is lacquered in gray 1 3 Thermal Insulation Thermal insulation is available as a separate item For easier handling the insulation shall not be fitted on the tank untilit reaches its definite p...

Страница 3: ...23 Application Storage and subsequent distribution of thermal energy from solid fuel boilers heat pumps or other heat sources Energy efficiency data as per EC Regulation No 813 2013 with insulation En...

Страница 4: ...d according to the circuits to be connected 5 Typical Layout Examples with Thermal Store Example I Heat pump and electric heating element KEY 1 Regulus heat pump RTC CTC 2 pump station for heat pump C...

Страница 5: ...ng system CSE MIX 9 pump station for DHW heating CSE OTS ZV 10 pump station for DHW recirculation CSE TVMIX ZV 11 safety kit for HW storage tank 12 DHW expansion vessel SV cold water TV hot water CV h...

Страница 6: ...ves for heating systems should be used The quality of heating water depends on the quality of filling water at commissioning on the top up water quality and on the frequency of topping up This has a s...

Страница 7: ...nual was not respected the product was used for other purposes than intended Warranty does not cover usual wear and tear damage caused by fire water electricity or another natural disaster defects cau...

Страница 8: ...or solvents Check all tank connections for leaks 9 Disposal Packaging shall be disposed of in compliance with the valid rules When the product reaches the end of its life it shall not be disposed of a...

Отзывы: