Regulus PS 1100 K+ Скачать руководство пользователя страница 3

3 - Dimensions and Other Technical Data

PS  

400 K+

PS  

500 K+

PS  

600 K+

PS  

700 K+

PS  

900 K+

PS

1100 K+

pos. connections

height [mm]

Heat sources

B1

G6/4" F

1365

1375

1385

1395

1415

1435

B2

G6/4" F

225

235

245

255

275

300

Heating system

H1

G6/4" F

1665

1685

1705

1725

1765

1815

H2

G6/4" F

225

235

255

255

275

300

Control and safety

C1

G1/2" F

1365

1375

1385

1395

1415

1435

C2

G1/2" F

515

570

535

545

565

585

C3

G1/2" F

1065

1075

1085

1095

1115

1135

T

G1/2" F

1245

1255

1265

1275

1295

1315

P

G1/2" F

425

425

425

425

425

445

Control and safety

U1

G6/4" F

1365

1375

1385

1395

1415

1435

U2

G6/4" F

425

425

435

445

465

490

U3

G6/4" F

985

995

1005

1015

1035

1055

U4

G6/4" F

605

615

625

635

655

675

U5

G6/4" F

1145

1155

1520

1175

1195

1220

Thermal store

PS 400 K+

PS 500 K+

PS 600 K+

PS 700 K+

PS 900 K+

PS 1100 K+

Code

Tank

15285

15288

15291

15294

15297

16119

Insulation (accessory)

19338

19307

19314

19300

19326

19323

Application

Storage and subsequent distribution of thermal energy from solid-fuel boilers, heat pumps 

or other heat sources.

Energy efficiency data (as per EC Regulation 

No. 813/2013)

with insulation

Energy efficiency class

C

C

x

x

x

x

Standing loss

85 W

93 W

102 W

116 W

125 W

144 W

Storage volume

403 l

477 l

560 l

737 l

861 l

1085 l

Technical data
Total tank volume

403 l

477 l

560 l

737 l 

861 l

1085 l

Max. working temperature in tank

95 °C

95 °C

95 °C

95 °C

95 °C

95 °C

Max. working pressure in tank

4 bar

4 bar

4 bar

4 bar

4 bar

3 bar

Heating elements max. length/output

680 mm / 

 

9 kW

700 mm / 

 

9 kW

755 mm / 

 

9 kW

815 mm / 

 

12 kW

815 mm / 

 

12 kW

955 mm /

 

12 kW

Materials
Tank material

S235JR

Dimensions, tipping height, weight
Tank diameter 

600 mm

650 mm

700 mm

790 mm

850 mm

950 mm

Tank diameter with insulation

800 mm

850 mm

900 mm

990 mm

1050 mm

1150 mm

Tank overall height

1665 mm

1685 mm

1705 mm

1725 mm

1765 mm

1815 mm

Tipping height without insulation

1700 mm

1720 mm

1750 mm

1780 mm

1820 mm

1850 mm

Weight

65 kg

72 kg

76 kg

93 kg

114 kg

117 kg

Accessories
El. heating element

ETT-A, C, D, F, P, M

Содержание PS 1100 K+

Страница 1: ...www regulus eu PS K PS K EN Installation and Operation Manual THERMAL STORES PS 400 K PS 500 K PS 600 K PS 700 K PS 900 K PS 1100 K...

Страница 2: ...surface is lacquered in gray 1 3 Thermal Insulation Thermal insulation is available as a separate item For easier handling the insulation shall not be fitted on the tank untilit reaches its definite p...

Страница 3: ...23 Application Storage and subsequent distribution of thermal energy from solid fuel boilers heat pumps or other heat sources Energy efficiency data as per EC Regulation No 813 2013 with insulation En...

Страница 4: ...d according to the circuits to be connected 5 Typical Layout Examples with Thermal Store Example I Heat pump and electric heating element KEY 1 Regulus heat pump RTC CTC 2 pump station for heat pump C...

Страница 5: ...ng system CSE MIX 9 pump station for DHW heating CSE OTS ZV 10 pump station for DHW recirculation CSE TVMIX ZV 11 safety kit for HW storage tank 12 DHW expansion vessel SV cold water TV hot water CV h...

Страница 6: ...ves for heating systems should be used The quality of heating water depends on the quality of filling water at commissioning on the top up water quality and on the frequency of topping up This has a s...

Страница 7: ...nual was not respected the product was used for other purposes than intended Warranty does not cover usual wear and tear damage caused by fire water electricity or another natural disaster defects cau...

Страница 8: ...or solvents Check all tank connections for leaks 9 Disposal Packaging shall be disposed of in compliance with the valid rules When the product reaches the end of its life it shall not be disposed of a...

Отзывы: