![Regulus PS 1000 E+ Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/regulus/ps-1000-e/ps-1000-e_installation-and-operation-manual_1434435005.webp)
KEY
1 – hot water storage tank
2 – electric heating element with thermostat
3 – thermal store for central heating - PS xxx E+ (ES+)
4 – heating system expansion vessel
5 – boiler load unit - thermostatic
6 – biomass boiler (fireplace insert/stove)
7 – pump station for heating system - CSE MIX
8 – pump station for DHW heating – CSE OTS ZV
9 – pump station for DHW recirculation – CSE
TVMIX ZV
10 – safety kit for HW storage tank
11 – DHW expansion vessel
SV – cold water
TV – hot water
CV – hot water recirculation
ÚT
– central heating (heating system)
KK – ball valve
ZV – check valve
AOV – automatic air vent valve
PTR – pressure temperature relief valve
REDV – pressure reducing valve (optional)
VK – drain valve
SVE – expansion vessel service valve
PV
-ÚT
– safety valve for heating system
MFB – Magnet Filterball
F – filter
BVTS – safety relief valve of boiler cooling loop
5
│
4 - Operation
In a thermal store, heating water can be heated up by various types of hot-water boilers, or possibly also by electric
heating elements.
The thermal store is connected to the energy source using a G 6/4“ connection fitting. The individual tank outlets are
fitted according to the circuits to be connected.
5 - Typical Layout Example with Thermal Store
Example
Biomass boiler (fireplace insert/stove)