KEY

1 – hot water storage tank

2 – electric heating element with thermostat

3 – thermal store for central heating - PS xxx E+ (ES+)

4 – heating system expansion vessel

5 – boiler load unit - thermostatic

6 – biomass boiler (fireplace insert/stove)

7 – pump station for heating system - CSE MIX 

8 – pump station for DHW heating – CSE OTS ZV

9 – pump station for DHW recirculation – CSE 

TVMIX ZV

10 – safety kit for HW storage tank 

11 – DHW expansion vessel

SV – cold water

TV – hot water

CV – hot water recirculation

ÚT

 – central heating (heating system)

KK – ball valve

ZV – check valve

AOV – automatic air vent valve

PTR – pressure temperature relief valve

REDV – pressure reducing valve (optional)

VK – drain valve

SVE – expansion vessel service valve

PV

-ÚT

 – safety valve for heating system

MFB – Magnet Filterball

F – filter

BVTS – safety relief valve of boiler cooling loop

4 - Operation

In a thermal store, heating water can be heated up by various types of hot-water boilers, or possibly also by electric 

heating elements.

The thermal store is connected to the energy source using a G 6/4“ connection fitting. The individual tank outlets are 

fitted according to the circuits to be connected.

5 - Typical Layout Example with Thermal Store

Example

Biomass boiler (fireplace insert/stove)

Содержание PS 1000 E+

Страница 1: ...www regulus eu PS E PS E EN Installation and Operation Manual THERMAL STORES PS 500 E PS 750 E PS 1000 E PS 1100 E PS 1250 E...

Страница 2: ...item For easier handling the insulation shall not be fitted on the tank until it reaches its definite place of installation The insulation is made of fleece 100 mm thick with a hard polystyrene surfa...

Страница 3: ...3 3 Dimensions and Other Technical Data H1 U1 C1 U2 C2 U3 H2 De Di V...

Страница 4: ...m 2080 mm 2065 mm Tipping height without insulation 1940 mm 2020 mm 2120 mm 2130 mm 2120 mm Heating elem max length output 680 mm 9 kW 755 mm 9 kW 815 mm 12 kW 815 mm 12 kW 955 mm 12 kW Empty weight 6...

Страница 5: ...KK ball valve ZV check valve AOV automatic air vent valve PTR pressure temperature relief valve REDV pressure reducing valve optional VK drain valve SVE expansion vessel service valve PV T safety val...

Страница 6: ...his has a strong influ ence on the lifetime of heating systems Poor quality of heating water may cause problems like corrosion or incrustati on esp on heat transfer surfaces Fill the heating circuits...

Страница 7: ...nual was not respected the product was used for other purposes than intended Warranty does not cover usual wear and tear damage caused by fire water electricity or another natural disaster defects cau...

Страница 8: ...r solvents Check all tank connections for leaks 9 Disposal Packaging shall be disposed of in compliance with the valid rules When the product reaches the end of its life it shall not be disposed of as...

Отзывы: