Regulus PS 1000 E+ Скачать руководство пользователя страница 2

 

2

CONTENTS

1 Description .................................................................................................................................................... 

2

 

1.1 Models ............................................................................................................................................... 

2

 

1.2 Tank Protection .................................................................................................................................. 

2

 

1.3 Thermal Insulation ............................................................................................................................. 

2

 

1.4 Connection points on the tank ........................................................................................................... 

2

 

1.5 Packaging.......................................................................................................................................... 

2

2 General Information ...................................................................................................................................... 

2

3 Dimensions and Other Technical Data ........................................................................................................ 

3

4 Operation........................................................................................................................................................ 

5

5 Typical Layout Example with Thermal Store .............................................................................................. 

5

6 Installation and Commissioning .................................................................................................................. 

6

 

6.1 Connection to heat sources .............................................................................................................. 

6

 

6.2 El. heating element installation ......................................................................................................... 

6

 

6.3 Commissioning .................................................................................................................................. 

6

7 Installing Insulation on the Tank ................................................................................................................. 

6

8 Maintenance................................................................................................................................................... 

8

9 Disposal ......................................................................................................................................................... 

8

10 Warranty ......................................................................................................................................................... 

8

1 - Description

PS E+ Thermal Stores are intended for storing and subsequent distribution of thermal energy from solid-fuel fired boi

-

ler. 230V or 3x230V/400V heating elements (2-12 kW output) can be installed directly into the 6/4” connections. Tanks 

are fitted with four side connections, one top connection and two connections for sensor sheaths. A 100mm thick 

insulation for these tanks can be purchased as a separate item.  

1.1 - Models

Five models of 473, 756, 927, 1038 and 1260 l capacity.

1.2 - Tank protection

The inner surface has no finish, no anticorrosion protection, the outer surface is lacquered in gray.

1.3 - Thermal Insulation

Thermal insulation is available as a separate item. For easier handling, the insulation shall not be fitted on the tank 

until it reaches its definite place of installation. The insulation is made of fleece, 100 mm thick, with a hard polystyrene 

surface. It is closed by a quick lock.

1.4 - Connection points on the tank

4× side connections, G 6/4“ F thread 

1× top connection, G 6/4“ F thread

2× side connections for sensor sheaths, G 1/2“ F thread

1.5 - Packaging

Thermal stores are delivered standing, each screwed to its separate pallet, packed in bubble wrap.

2 - General Information

This Manual is an integral and important part of the product and must be handed over to the User. Read carefully the 

instructions in this Manual as they contain important information concerning safety, installation, operation and mainte

-

nance. Keep this Manual for later reference. The appliance shall be installed by a qualified person according to valid 

rules and Manufacturer‘s Instructions, otherwise the Warranty is null and void.

This appliance is designed to accumulate thermal energy of heating water and distribute it subsequently. It must be 

connected to a heating system and heat sources. 

Using the thermal store for other purposes than above described is forbidden and the manufacturer accepts 

no responsibility for damage caused by improper or wrong use. The thermal store must not be used as a hot 

water storage tank!

Содержание PS 1000 E+

Страница 1: ...www regulus eu PS E PS E EN Installation and Operation Manual THERMAL STORES PS 500 E PS 750 E PS 1000 E PS 1100 E PS 1250 E...

Страница 2: ...item For easier handling the insulation shall not be fitted on the tank until it reaches its definite place of installation The insulation is made of fleece 100 mm thick with a hard polystyrene surfa...

Страница 3: ...3 3 Dimensions and Other Technical Data H1 U1 C1 U2 C2 U3 H2 De Di V...

Страница 4: ...m 2080 mm 2065 mm Tipping height without insulation 1940 mm 2020 mm 2120 mm 2130 mm 2120 mm Heating elem max length output 680 mm 9 kW 755 mm 9 kW 815 mm 12 kW 815 mm 12 kW 955 mm 12 kW Empty weight 6...

Страница 5: ...KK ball valve ZV check valve AOV automatic air vent valve PTR pressure temperature relief valve REDV pressure reducing valve optional VK drain valve SVE expansion vessel service valve PV T safety val...

Страница 6: ...his has a strong influ ence on the lifetime of heating systems Poor quality of heating water may cause problems like corrosion or incrustati on esp on heat transfer surfaces Fill the heating circuits...

Страница 7: ...nual was not respected the product was used for other purposes than intended Warranty does not cover usual wear and tear damage caused by fire water electricity or another natural disaster defects cau...

Страница 8: ...r solvents Check all tank connections for leaks 9 Disposal Packaging shall be disposed of in compliance with the valid rules When the product reaches the end of its life it shall not be disposed of as...

Отзывы: