![Regulus LYRA 1000 DVS Скачать руководство пользователя страница 34](http://html1.mh-extra.com/html/regulus/lyra-1000-dvs/lyra-1000-dvs_installation-and-operation-manual_1434490034.webp)
│
34
6 - Installation and Commissioning
Installation shall meet valid rules and may be done by quali
fi
ed staff only. El. heating elements shall be wired by quali
fi
ed
staff only.
Defects caused by improper installation, use or handling are not covered by warranty.
After the tank is installed and connected to an existing heating system, it is recommended to clean the entire heating
system using a suitable cleaning agent, e.g. MR-501/R.
Anti-corrosion protective liquid should be also used, e.g. MR-501/F.
6.1 - Commissioning
The tank shall be
fi
lled up together with the heating system, respecting valid standards and rules. In order to minimize
corrosion, special additives for heating systems should be used. The quality of heating water depends on the quality of
fi
lling
water at commissioning, on the top-up water and on the frequency of topping up. This has a strong in
fl
uence on the lifetime
of heating systems. Poor quality of heating water may cause problems like corrosion or incrustation, esp. on heat transfer
surfaces.
Fill the heating circuits with the appropriate
fl
uids and air-bleed the entire system. Check all connections for leaks
and verify the system pressure. Set the heating controller in compliance with the documentation and manufacturer’s
recommendations. Check regularly proper function of all control and adjusting elements.
7 - Maintenance
If the tank is
fi
tted with a heating element, disconnect it from the mains
fi
rst. Clean the exterior of the tank with a soft
cloth and a mild detergent. Never use abrasive cleaners or solvents.
Check all connections for leaks.
8 - Disposal
Packaging shall be disposed of in compliance with the valid rules. When the product reaches the end of its life, it shall
not be disposed of as household waste. It shall be dropped off at a Local Waste Recycling Center. Insulation shall be
recycled as plastic and the steel vessel as scrap iron.
9 - Warranty
This product is covered by warranty under the conditions listed in this Manual and in compliance with the Warranty
Certi
fi
cate. A Warranty Certi
fi
cate is an integral part of this Thermal Store scope of supply.