EXAMPLE III.
Heat pump with max.
fl
ow temperature over 60°C, el. heating elements
5.6. Fitting electric heating elements
The Thermal Store can be
fi
tted with up to 2 electric heating elements of max. 12 kW total power output. The G6/4”
sleeves, located in the middle of the tank below the heating pump station, are intended for these elements. The G1/2”
sleeve below the upper thermometer is designed to receive a safety thermostat. All el. heating elements shall be
installed together with a safety temperature limiter.
El. heating elements shall be wired by qualified staff only.
safety thermostat
el. heating elements
heat pump
65 °C max. flow temp.
Expansion Vessel Connection Kit (code 13437)