12
Regulus CSE2 MIX F G60 1F - www.regulus.eu
5. PUMP STATION INSTALLATION
The pump station is designed to be mounted on a wall or a manifold with 125 mm connection
pitch. In the rear section of the insulation there are two mounting holes for fixing the metal
plate to the wall. Mounting holes pitch is 80 mm.
The package includes a mounting kit that is used to fix the pump station to the
intended place. The mounting kit includes:
Screw 5x50, round head
2 pcs
6.4 stainless steel washer, DIN 9021/A2 2 pcs
Wall plug 8mm TX
2 pcs
340
360
125
245
Permitted and prohibited positions of the pump station
Permitted position Conditionally permissible positions
Prohibited position
(may be used when a filter is replaced by
the filter replacement section, code 19017)
Installation dimensions are shown in the figure.
+
+