Regulus 18514 Скачать руководство пользователя страница 1

www.regulus.

eu

IR 1

CTC 

 

EN

Instruction Manual

 

IR 

14

 Heating Controller

 

V

.

IR1

4 CTC 

Valid for FW 1.0.

5

.0 

IR 1

CTC 

Содержание 18514

Страница 1: ...www regulus eu IR 14 CTC EN Instruction Manual IR 14 Heating Controller V IR14 CTC Valid for FW 1 0 5 0 IR 14 CTC ...

Страница 2: ...er heated by auxiliary heat source DHW E 14 2 10 Setting temperatures for thermal store 15 2 11 DHW recirculation settings 15 2 12 Statistics 15 2 13 Operating data 16 2 14 Other 16 2 15 Time and date setting 16 2 16 RegulusRoute parameters of connection with the service 17 3 Additional modules 18 4 Web interface 19 4 1 Home screen 20 4 2 Display of the Diagram DIAGRAM 23 4 3 Heating zone menu HEA...

Страница 3: ...pple control signal Each of the analogue inputs can be used a a binary input Further it features 11 relay outputs 250V 3A and two PWM 0 10V outputs capable of continuous control The Controller is fitted with an Ethernet interface f or a service intervention firmware upgrades and eventually elementary visualization of the concerned heating system The Controller also features an RS485 communication ...

Страница 4: ...1 1 Basic User Menu Pressing ESC in the basic User menu will always bring back the first basic display 1 outdoor temperature 2 weekday and time 3 temperature in zone if room temp sensor is used 4 heating water temperature if no room temp sensor is used 5 temperature in thermal store 6 temperature in DHW storage tank Heating zone display zone 1 zone 2 1 zone state information on the current heating...

Страница 5: ...EDED block cool t COOLING BELOW ZONE TEMPERATURE cool other z COOLING IN ANOTHER ZONE block period HEATING BLOCKED IN SET PERIOD block outd t HEATING BLOCKED BY OUTDOOR TEMPER off time prog TIME PROGRAM SETBACK ZONE OFF block room t ROOM TEMPERATURE REACHED air cooling AIR COOLING cool active COOLING ACTIVE floor drying FLOOR DRYING PROGRAM comf low out t COMFORT LOW OUTDOOR TEMPERATURE time prog ...

Страница 6: ...ng 7 DHW storage tank 3 not used Display of DHW zone heated by an auxiliary heat source DHW E 1 zone state on off no 2 current temperature in DHW tank 3 desired temperature in DHW tank 4 heating by el element heat no heat Display of DHW zone heated by a heat pump DHW 1 zone state on off no 2 current temperature in DHW tank 3 desired temperature in DHW tank 4 heating by heat pump heat no heat ...

Страница 7: ...th circ heat pump is blocked by max brine circuit temperature vapor low T heat pump is blocked by low evaporation temperature vapor high T heat pump is blocked by high evaporation temperature cond high T heat pump is blocked by high condensing temperature EEV low T intake heat pump is blocked by expansion valve s low suction gas temp EEV low T vapor heat pump is blocked by expansion valve s low ev...

Страница 8: ...tart heating as soon as there is call for heat Display of auxiliary heat source and thermal store 1 state of auxiliary source heat no heat none 2 current thermal store temperature desired 3 Ripple control signal on off Display of auxiliary heat source connected via OpenTherm interface 1 state of OT source heat no heat none 2 real flow temp of OT source 3 state of communication with OT source OK er...

Страница 9: ...n factory setting If the display shows the text above with warning about the controller being reset to default settings it is necessary to contact a service provider who shall set the respective controller parameters ...

Страница 10: ...ting heat sources and other parameters Access to the Service Menu is password protected and parameter adjustments in the service menu are not intended for laymen circulation setting of immediate DHW recirculation circulation period After the set recirculation time expires the function will be turned off automatically zones 3 to 6 basic setting of heating zones 3 to 6 zones have to be connected to ...

Страница 11: ... and valve can be activated by frost protection if on and active Summer winter mode state Switching on off the function for automatic transition between summer and winter modes Summer Winter mode is intended to turn on zone heating when the outdoor temperature stays below the preset threshold temperature winter temp for a certain time winter time and vice versa to turn off zone heating when the ou...

Страница 12: ...d to one of the controller inputs see the service level power see boost 1 2 3 duration hh mm see boost 1 2 3 Summer bypass settings summer bypass Switching on the Summer bypass function This function can be assigned to a room sensor in one of heating zones however onky when a room sensor unit is present in the respective zone The sensor used is defined by the parameter assign function to zone This...

Страница 13: ...g curve is calculated from heating system parameters that are entered on the Controller service level On the User level the basic curve can be shifted in parallel or its inclination changed using two parameters OTC curve shift C OTC curve shift for the set outdoor temperatures of 15 C and 15 C When the curve is shifted at one of the points the other point always remains unchanged i e the curve rot...

Страница 14: ...t sources 2 8 Settings of hot water heated by heat pump DHW DHW on Switching on DHW heating by heat pump on the User level T comfort C Desired temperature in Comfort mode T setback C Desired temperature in Setback mode During a day the controller switches the desired DHW temperature from HP by the preset time schedule 2 9 Settings of hot water heated by auxiliary heat source DHW E Basic settings o...

Страница 15: ...d temperature in Setback mode During a day the controller switches the desired thermal store temperature by the preset time schedule The real desired thermal store temperature is the maximum of all demands from zones heating zones thermal store zone demands from universal functions 2 11 DHW recirculation settings DHW recirculation and its time program settings on the User level When recirculation ...

Страница 16: ...etting the default values are set username user password user Lang of heat pump state and error email language Selection of the language in which the heat pump statuses sensor names blocks and system faults will be displayed on the display and on the web 2 15 Time and date setting Time and date shall be set to ensure proper operation of time programs zones recirculation DHW heating etc Clock is se...

Страница 17: ...t Regulus RegulusRoute displays whether the service is on Service status displays the current service status and error information Then follows the information about IR driver remote server of RegulusRoute service along with a detailed description of the last fault of the service This information can be useful when solving connection errors with a service technician IR name IR14 Controller login n...

Страница 18: ...ce flow temperature Damper Display of how opened is the damper of the air supply to the fireplace DHW pump Display of the state of pump for DHW heating from Thermal Store on off UNI module UNI module 2 Output on off State of universal output of UNI module 1 2 displayed T1 C Display of t1 temperature from UNI module 1 2 T2 C Display of t2 temperature from UNI module 1 2 ...

Страница 19: ... is connected to a LAN by entering its IP address into the browser address bar the initial login form will be displayed Login name for user level is user Password for user level is user After login to the IR controller via the website interface through IR Client app or RegulusRoute service the basic screen with tiles appears In the mobile version of the website it is possible to expand the menu by...

Страница 20: ...s basic information about the two heating zones DHW heating recirculation and Heat Recovery Ventilation zone Service enabled zones are highlighted in colour and can be controlled Service deactivated zones are only shown and cannot be controlled ...

Страница 21: ...21 The home page displayed in a computer browser The home page displayed in the IR Client mobile app ...

Страница 22: ...n be increased or decreased with the plus and minus buttons Heating zones current room temperature if a room sensor is installed DHW zone DHW temperature The ON OFF button is used to turn the zone on or off on user level Sun Moon comfort setback The snowflake indicates active cooling Information about the current zone mode Current HRV unit fan power in percent Clicking on this button will open the...

Страница 23: ...ed here according to the distributor rate HIGH LOW HOLIDAYS here it is displayed whether or not the holiday function is active This function allows you to adjust the heating temperature of the individual zones and the hot water to a lower value during a longer stay outside the heated building without changing the permanent settings in the individual zones Holidays are controlled in the HEATING men...

Страница 24: ... can be switched on by frost protection if switched on and active Room temperature setting Comfort temperature Setting the comfort temperature in zone The temperature can be also modified using the plus and minus keys Setback temperature Setting the setback temperature in zone The temperature can be also modified using the plus and minus keys The setback temperature can only be set with the time p...

Страница 25: ... Use second period Use the second period of the time program Allows a second transition between setback and comfort mode and back Pre set time periods can be easily overwritten The following buttons are meant to copy easily the set values to further days COPY Mo TO Mo Fr Mo Su and COPY Sa TO Sa Su Winter Summer function settings blocks heating in summer When activating HEATING BLOCKED IN SET PERIO...

Страница 26: ...26 In winter mode zone heating is switched on the zone is heated to the required temperature according to the current comfort setback mode In summer mode zone heating is switched off ...

Страница 27: ...ng commissioning at the service level It can be clearly seen in the graph below that weather compensating control does not represent a direct relationship between the outdoor temperature and the heating water temperature so its expression is not a straight line This model example shows a system with convection radiators with a temperature gradient of 55 50 C The outdoor design temperature is 15 C ...

Страница 28: ...bove zero If a building underheats at an outdoor temperature above zero the heating water temperature shall be increased with the plus button The graph shows that the heating water temperature will be adjusted mainly at temperatures above zero Building overheating at temperatures below zero If a building overheats at an outdoor temperature below zero the heating water temperature shall be reduced ...

Страница 29: ... Displays temperatures adjusted by the buttons at the current outdoor temperature SAVE CHANGES Confirmation of changes made saving them to the controller s memory CANCEL Return of values cancelling current changes RESTORE FACTORY SET Reset of the OTC curve to default values The expert setting is fully linked to the basic OTC curve setting and all changes are reflected in the zone setting Note When...

Страница 30: ...nd active heating zones The time program setting is identical to the time program setting in zones 1 6 4 3 3 Pool heating The pool heating function is only available if enabled in the service level Pool heating to adjustable desired temperature The heating can be switched on or off by the user with the ON OFF button 4 3 4 Holidays The Holiday function is intended for background heating of the buil...

Страница 31: ...he time program setting in zones 1 6 4 4 2 DHW by auxiliary heat source DHW heating by an auxiliary source can be switched on or off by the ON OFF button At the top of the page the status of the zone COMFORT SETBACK the actual and desired temperature in the hot water storage tank the switching on and off differences and the operating hours of the heat source are displayed Heat source switch on off...

Страница 32: ...l to the time program setting in zones 1 6 USE TIME PROGRAM OF DHW ZONE For starting the circulation pump a time program is set identical to the time program for DHW heating by the heat pump The circulation pump starts following the set intervals circulation time and idle time only in comfort mode according to the time program Immediate recirculation After this function is activated the circulatio...

Страница 33: ... cooling from ground boreholes is possible with CTC heat pumps Current status of the heat pump information on compressor operation for inverter models also compressor speed Heat pump operation statistics operating hours and number of starts Statistics of DHW heating by heat pump operating hours and number of starts Heat pump inlet temperature heating return and heat pump outlet temperature Time pe...

Страница 34: ...mal system He will adjust solar appliances and their values to the current system requirements to ensure long service life and efficiency of solar heating Current temperature of solar collectors Solar pump operation information Current temperature temperature measured by the hot water storage tank sensor Desired temperature desired temperature for solar heating of a given hot water storage tank Ma...

Страница 35: ...ve the thermal store temperature the pump is switched on OFF Switch off difference If the difference between the boiler and thermal store temperatures is lower than the value of the switch off difference the boiler pump is switched off Current measured values on the control sensors for switching the boiler pump Status of boiler pump and air supply damper displayed as a percentage of air supply ope...

Страница 36: ...ference between the setback and comfort temperature With a higher difference of these temperatures the desired heating water temperature increases by more than 5 C which activates the auxiliary source At mild outdoor temperatures the heat pump can reach the required temperature within 45 minutes thus canceling the activation of the auxiliary source The auxiliary heat source is blocked above an out...

Страница 37: ...dulated sources equipped with OpenTherm communication To control them an add on module for OpenTherm communication needs to be connected to the controller Change of source operation mode heating DHW heating and summer operation DHW heating only Current status and output of the modulated heat source Important measured temperatures and desired temperature for the OpenTherm source Information on the ...

Страница 38: ... 10V voltage signal Measured temperature at the control sensor and desired temperature for the auxiliary heat source Current output of the source in percent Limitation of the minimum and maximum boiler outlet temperature These values are set by the technician in the service menu during commissioning Status of auxiliary heat source and Ripple control if used ...

Страница 39: ...ations E mail notifications can be switched on or off with the ON OFF button The e mail notification function is used to send e mails with information about faults or non standard operation of the heating system caused mainly by incorrect user settings E mail notifications only work with a controller that is connected to the Internet To better identify the specific controller it is advisable to fi...

Страница 40: ... the yr no website When the forecast is displayed an address will appear in the address bar in the form www yr no place XXXXX YYYYY ZZZZZ where XXXXX is a state YYYYY region and ZZZZZ location 4 6 6 Functions overview All functions of the controller are displayed in the function overview Depending on the selected controller settings the functions switched on the service and user level are highligh...

Страница 41: ...Boost can be switched on or off with the ON OFF button Up to 3 boost periods can be preset and then activated in these sections After switching on the boost function the ventilation unit sets the output to the value set in the Desired power field for the time Boost period Summer bypass function The Summer bypass flap function can be switched on or off with the ON OFF button In this section the des...

Страница 42: ...nd the alternation of comfort setback modes Only passive cooling from ground boreholes is possible with CTC heat pumps To activate the heat pump to cooling mode it is necessary to turn on the option of cooling by the heat pump in the heat pump menu 4 6 9 Universal outputs Information on universal functions UNI function and UNI function 2 These functions are fully configurable from the service inte...

Страница 43: ...erating data 57 5 7 HP blocking 58 5 8 Settings for an ON OFF source 58 5 9 Settings for an auxiliary source with OpenTherm 59 5 10 Settings for a modulated 0 10V heat source 60 5 11 Settings for DHW heating by a heat pump DHW 60 5 12 Settings for DHW heating by an auxiliary source DHW E 60 5 13 Settings for thermal store heating 61 5 14 Sensor management 61 5 15 Other service settings 61 5 16 Fir...

Страница 44: ...44 1 Controller Wiring Warning Controller wiring may be performed by a qualified person only Layman adjustments of the controller may cause damage to parts of the system ...

Страница 45: ...102 ThSt lower 103 DHW upper 104 DHW lower 105 Solar 106 solid fuel boiler 107 heating water zone 2 108 room temp zone 2 109 sensor 1 110 sensor 2 LIST OF OPTIONAL FUNCTIONS FOR OUTPUTS B2 B3 201 PWM output for circ pump in HP1 202 PWM output for circ pump in HP 2 203 PWM output for circ pump in HP 3 204 PWM output for SOL circ pump 205 0 10V for boiler control 206 0 10V for HRV control 207 0 10V ...

Страница 46: ... 230 V AC Relay type electromechanical Analogue outputs 0 10 V AO0 to AO1 Output voltage 0 to 10 5 V DC Common conductor GND Max current 10 mA Analogue inputs AI0 to AI13 Temperature inputs resistance sensors Pt 1000 90 C to 400 C Pressure sensor transducer current loop 4 20 mA Common terminal GND 3 Technical data for OpenTherm module Power supply voltage 24 V DC 5 Power consumption max 0 24 W Ins...

Страница 47: ...rail in a power distribution box It may be installed by a properly qualified person only The Controller and power supply unit shall be installed next to each other see wiring fig The recommended min cross section of the power supply conductors is 0 75 mm2 Heat pump wiring diagram ...

Страница 48: ...or the IR14 controller Module Module Zdroj Power supply Tepelné čerpadlo Heat pump Oběhové čerpadlo Circulation pump of the heat pump Kotel s opentherm Boiler with opentherm Boiler wiring diagram with OpenTherm communication The address switch of the OT module shall be set to pos 0 ...

Страница 49: ...g program solar setting service parameters for solar thermal system heat pump setting service parameters for heat pump HP operat data detailed info on heat pump HP blocking detailed info on heat pump source on off setting service parameters for ON OFF source source OT setting service parameters for source with OT communication source 0 10V setting service parameters for 0 10V source DHW setting se...

Страница 50: ... means that if the heating water temperature changes by 3 C the room temperature will change by circa 1 C This parameter applies when no room sensor is present external blocking input sensor list Setting the terminal to which an input will be connected that is used for blocking the heating zone externally It is possible to select any free input to IR or inputs from an add on digital input module i...

Страница 51: ...be set when the HRV unit is switched off by user Summer bypass function Summer bypass Switching on the Summer bypass function on the Service level This function can be related to a room sensor in any of heating zones however only when a room sensor is present in the respective zone or possibly a room unit The installed sensor is defined by the parameter Summer bypass off assign function to This fu...

Страница 52: ...nsor sensor list Choice of temperature sensor in a solar tank diff on C Difference to switch on heating from solar circuit Difference between solar collector and temperature sensor set in parameter sensor diff off C Difference to switch off heating from solar circuit desired t C The desired temperature Under the normal solar circuit mode the tank is heated up to this temperature As soon as all swi...

Страница 53: ...meter Solar consumer no for collector tank cooling If the temperature in this tank exceeds the preset critical tank temperature collector cooling is stopped on active off Switching on the function of collector cooling crit storT C Setting a critical tank temperature Collector cooling by heating the tank selected in parameter Solar consumer no for collector tank cooling may run only until the tank ...

Страница 54: ...t to maximum for the period defined in parameter purge time then the speed drops to minimum and is increased decreased following the predefined period by the set control step solar PWM pump on off Switching on the PWM pump function set differ K Desired temperature difference between solar collector and storage tank purge time mm ss Purging time time when pump is running at maximum power after swit...

Страница 55: ...rmal store diverts in advance before the HP s compressor starts HP active no This activates the function of heat pump cascade control It shall be active even when just one heat pump is used diff on C Temperature difference to switch on a heat pump cascade A difference between the desired thermal store sensor temperature and the real temperature to switch on the heat pump diff off C Temperature dif...

Страница 56: ...ng demand Ripp for DHW yes no Ripple c for DHW With no the heat pump runs disregarded of the Ripple control signal No block by Ripple control under set outdoor temp yes no Heat pump is not blocked by Ripple c during DHW heating under the set outdoor temp outdoor temp C Outdoor temperature below which HP will not be blocked by Ripple c during DHW heating external blocking input sensor list Setting ...

Страница 57: ...eat pump is switched off Max brine t C Max brine circuit temperature When the brine temperature exceeds this value the heat pump is switched off Applies to ground coupled heat pumps only Restart time min Min delay between two heat pump starts Min run time min Minimum time of HP operation It is activated either after compressor start or after DHW heating is finished if the heating circuit demand is...

Страница 58: ...erature for switching on an auxiliary source diff off C Setting a temperature difference between the desired thermal store upper and real temperature for switching off an auxiliary source delay min Setting the delay for auxiliary source start after the demand for start appeared block out t C Setting outdoor temp above which an auxiliary source is blocked Ripple cont yes no Ripple control With no t...

Страница 59: ...peared block out t C Setting outdoor temperature above which an auxiliary source is blocked Ripple cont yes no Ripple control With no the auxiliary source runs disregarded of the Ripple control signal max temper C Max source temperature When this temperature is exceeded the source is switched off At the same time this is the upper limit for demands e g if a DHW demand is 95 C and a boiler max temp...

Страница 60: ...etting of max flow temperature from a heat source This temperature will be used as the upper limit value for a desired boiler temperature 5 11 Settings for DHW heating by a heat pump DHW on active off Switching on DHW heating by a heat pump on service level diff on C Setting the DHW heating switch on difference diff off C Setting the DHW heating switch off difference Control sensors sensor list Co...

Страница 61: ... be changed The setting depends on the system configuration E g when DHW zone is switched on in service level the HP sensor is activated while when the DHW zone is switched off the sensor deactivates automatically adjustment C bar Temperature sensor offset in case the value measured by the sensor differs from the real value This is intended e g to compensate for the resistance of a long sensor cab...

Страница 62: ...n be controlled directly via one of the optional outputs on terminal block F of the IR controller or via an add on module In this way the heating of the hot water storage tank from the thermal store can be effectively controlled Fireplace module on off Option if the module is used in the system ThSt sensor for Fire sensor list Selecting a sensor for differential function of switching on a fire cir...

Страница 63: ...unction can hold disconnection switching off from thermostat diff thermostat and delay functions The Timer function is superior over all the preceding functions Basic settings UNI function active on off Switching on the universal function sens 1 Selection of sensor 1 for universal function sens 2 Selection of sensor 2 for universal function Thermostat 1 Thermostat 2 Thermostat 1 is related to sens...

Страница 64: ...ns are switched on Overrun Output switch off delay function overrun minutes Output overrun time after the preceding functions are switched off Timer A simple timer with two time periods on 1 hh mm The first period switch on time off 1 hh mm The first period switch off time on 2 hh mm The second period switch on time off 2 hh mm The second period switch off time reset state of T1 T2 with every star...

Страница 65: ...ace of the controller module addr Hexadecimal HW address of a module load address no yes After entering the HW address confirm yes to load the address into the Controller The lower line will read OK and the green RUN lamp on the module will start flashing 5 19 IP addresses Setting the IP address network mask gateway DNS server address and DHCP server IP addresses are entered in the range from 0 0 ...

Страница 66: ...ng the newly entered name and password for RegulusRoute service parameters can be entered via web interface only 5 21 Output test When test in Service Menu is entered all outputs from the Controller are switched off Then separate outputs can be tested The output turns on when a display with the name of the output in question is shown and the option test 1 selected On leaving a display with the opt...

Страница 67: ...our computer s network adapter correctly In order to access the Controller s interface via web browser you need to know its IP address The IP address set in the Controller can be revealed by hitting DISP key Then pressing arrow down key will display the IP address of the device its mask and gateway Entering the IP address into the address bar of your browser will open a log in window that enables ...

Страница 68: ...gement Zones 3 to 6 Add on modules RCM2 RCD or RCA room units RCM2 RCD or RCA room units shall be connected to a CIB bus After connecting their HW address shall be entered in the menu module addr for zones 1 and 2 For other zones the web interface needs to be used RC25 room unit The RC25 room unit can also be connected to the Controller via the CIB bus It senses the room temperature and relative h...

Страница 69: ... the printed circuit board of the wireless sensor is used to select the power supply After pressing the WiFi settings button the blue LED lights up and the WiFi sensor creates an access point hotspot called Regulus_RSW It is necessary to connect to this access point using a PC or mobile device and set the parameters needed to connect the sensor to the Controller the IP address of the Controller an...

Страница 70: ...he Controller with an Ethernet cable 3 Set up a network connection on the PC On your computer right click on the internet connection icon small screen icon in the lower right corner Click the Network and Internet Settings link Click on Network and Sharing Center a window with a list of network connections will open Click Ethernet the connection status window will open Click on Properties at the bo...

Страница 71: ...ss 192 168 100 15 The three digits must be in the range 001 254 After filling in the IP address press the tab key on the computer keyboard This will automatically fill in the subnet mask 255 255 255 0 It is not necessary to fill in the next field Press OK The window will close However to save the settings it is necessary to press OK in the previous window with Ethernet settings too By entering the...

Страница 72: ...ions contained in the accompanying product documentation as well as on the product itself 5 The warranty does not cover defects caused by external influences or improper operating conditions when the product is not used in accordance with its intended use defects caused by normal wear and tear when the product is defective due to mechanical damage improper operation tampering by a third party impr...

Отзывы: