In order to prevent errors of the direction coordination, a visual 

noticeable tag should be placed on the magnetic tape surface, e .g . 

as  is  shown  in  Fig.  8  to  make  a  “start”  point  by  a  felt-tip  pen  at 

the beginning of the magnetic tape .

The magnetic carrier should be demagnetized as described in paragraph 

2.2.2.3 of Regula 7505M User’s Guide. The demagnetizer must be moved 

from left to right relative to the “start” point (see Fig . 8a) . 

The demagnetized magnetic tape is placed on the examined 

surface without overturns, i.e. so that the “start” point is always at 

the left edge .

When  carrying  out  magnetographing  the  demagnetizer  is  also 

moved from left to right relative to the “start” point (see Fig . 8b) . 

And the scanner body must be placed in the way that the direction of 

the arrow with the symbol indicating the type of examined materials 

and the direction of the preliminary demagnetization are the same, 

i .e . from left to right .

Note: 

If the device and Regula model 7505 are not delivered together, 

the  demagnetizer  may  exchange  the  polarity.  In  this  case  when 

carrying  out  scanning,  turn  over  the  tape  before  placing  it  on 

the object (“start” point to the right edge) .

Magnetic copy:

 

 

Put the magnetic tape on the prepared number area 

 

of a vehicle and fix its end on the examined surface by 

a magnetic clamp, adhesive tape or manually (try to avoid 

skewness and shifts relative to the examined number);

 

 

Fix the other end of the magnetic tape stripe in the same 

way (if one end of the magnetic tape stripe is fixed firmly, 

the  other  end  may  be  left  loose).  The  operator  may 

choose any way of the magnetic tape fixation;

 

 

Place the body of the device scanner so that the relief tag 

(Fig . 5, pos . 5) in the form of an arrow is directed forward 

in the scanning direction (Fig . 8b) . Put the scanner on 

the  fixed  stripe  of  the  magnetic  tape,  make  sure  they 

have a tight contact with the examined surface . 

 

 

Switch on the power supply of the device controller with 

the button (Fig . 3, pos . 3), make sure the green LED 

glows (Fig. 3, pos. 4). If necessary, hold down the button 

to choose the required power mode (for Fe-scanner only). 

The number of flashes is in proportion to the set power 

level of Fe-scanner;

 

 

Move the scanner slightly pressing it to the surface from 

the beginning of the examined fragment to the end . 

The speed of scanning should not exceed 50 mm/s . 

Содержание 7515M

Страница 1: ...EDDY CURRENT MAGNETOGRAPHING DEVICE REGULA 7515M Operating Manual 2019 MAGNETO OPTICAL DEVICES For nondestructive investigation of metal surfaces Certified Quality Management System...

Страница 2: ......

Страница 3: ...1 6 Marking 16 1 7 Packaging 16 2 INTENDED USE 17 2 1 Operating restrictions 17 2 2 Preparation for use 18 2 3 Device use 18 3 MAINTENANCE 27 3 1 General instructions 27 3 2 Safety measures 28 3 3 Ser...

Страница 4: ...of vehicle identification numbers VIN Regula 7505M The OM contains the information on the device and its design principle of operation and technical characteristics It also provides instructions on th...

Страница 5: ...residual accumulated tension Technical specifications Basic technical specifications of the device Table 1 Scanner supply voltage V 24 Current in scanner conductor peak value A 90 110 Magnetic field...

Страница 6: ...sing test objects 1 and 2 Magnetographing with the use of the device consists in the successive execution of a number of operations Demagnetize place and fix the magnetic tape on the examined surface...

Страница 7: ...re 2 Structural scheme of the device as a component of regula 7505M Device Scanner Charging Unit of Controller ACC converter 220V 24V Device Controller Stray field s record magnetogram Object VIN Surf...

Страница 8: ...socket for the network power unit top view b bottom view External view of the device controller 2 6 5 3 1 4 The device controller Fig 3 is produced in a metal body pos 1 The controller side slab has a...

Страница 9: ...aragraph 2 3 for the power levels None of LEDs glows ACCs are absent or are fully discharged the device controller malfunction The controller switches off automatically one minute after its activation...

Страница 10: ...tor To carry out magnetic copying fix a demagnetized magnetic tape on the examined surface And then move the scanner in the direction indicated by the arrow pos 5 along the examined area When carrying...

Страница 11: ...excite magnetic stray fields of the defects located in the subsurface layers of a ferromagnetic object during magnetic copying polar tips pos 9 of the magnetic excitation system should make tight cont...

Страница 12: ...is applied by machining process cold pressing The initial number was made in the following way manual stamping using 10 type markers kit and hammer on a massive anvil The depth of digits relief makes...

Страница 13: ...sing The initial number was made in the following way manual stamping using 10 type markers kit and hammer on a massive anvil The depth of digits relief makes about 0 3 0 4 mm All digits of the initia...

Страница 14: ...agnetic copy stitching with the control images for Al scanner are as follows compare the processing quality of the alteration features of the initial number digits the contours traces of the initial m...

Страница 15: ...ith the control images for Fe scanner are as follows compare the processing quality of the digits contours of the remoted initial number the contours outlines of all digits shall be visible in case of...

Страница 16: ...d month rated voltage V rated current A TC marking national mark of conformity certification Device seals are applied with destructive labels on the device controller body Sealing violation deprives t...

Страница 17: ...of the device elements stop the device operation and proceed with it only after drying the device should not be exposed to impacts and strong vibration when operating and transporting it observe qual...

Страница 18: ...h according to the state of indicators Fig 3 pos 4 as described in paragraph 1 4 If it is necessary charge ACC under paragraph 3 1 Press shortly the button Fig 3 pos 3 to turn off the device controlle...

Страница 19: ...rying out scanning turn over the tape before placing it on the object start point to the right edge Magnetic copy Put the magnetic tape on the prepared number area of a vehicle and fix its end on the...

Страница 20: ...corded to the tape in the form of vertical black and white lines To obtain a good quality copy the operator should control the contact between the scanner and the examined surface visually and manuall...

Страница 21: ...impossible e g due to lack of the visualization device make 1 2 safety magnetic copies more Choosing the optimal level of magnetographing power The level of magnetographing power is regulated by holdi...

Страница 22: ...ant superficial defects pos 3 All above mentioned relief elements including scratches pos 1 and pos 2 are clearly observed aas a result of visualizing the magnetogram of the examined object Fig 9b and...

Страница 23: ...optical visualization results of the object magnetogram b The aluminum object has superficial ferromagnetic inclusions 1 scratches of 200 300 m width 2 scratch of 100 m width 3 insignificant superfic...

Страница 24: ...tant control feature as it enables to examine e g the ways of VIN data alterations based on welding technologies The following example Fig 11 shows the probabilities of sensitivity increase of magneto...

Страница 25: ...s 2 surface scratches 3 overlap of electrode metal 4 paths of machining process Photo image a and magneto optical visualization results of the object magnetogram b made of aluminum alloy with a trimme...

Страница 26: ...26 Figure 11 The results of magneto optical visualization of magnetograms of the test object made of ferromagnetic alloys with minimal a medium b and maximal c power levels of the Fe scanner a b c...

Страница 27: ...s prohibited to use abrasive materials for cleaning the inductors It may lead to damaging the contact layer of the inductor Approximate ethyl alcohol consumption per working shift makes 5 g Technical...

Страница 28: ...arging unit from the wall outlet Carry out function control according to paragraph 2 2 Safety measures Observe safety measures as described in paragraph 2 1 when performing the device technical mainte...

Страница 29: ...nstalling the inductor ATTENTION DO NOT INSTALL HOMEMADE INDUCTORS ON THE SCANNER IT MAY DISABLE THE DEVICE IT IS ALLOWED TO USE ONLY THE INDUCTORS PRODUCED BY THE MANUFACTURER Inductor replacement is...

Страница 30: ...insulating substrate of the inductor 2 electroconductive layer of the inductor 3 contact areas of the inductor 4 contact pads of the scanner 5 arrow showing the direction of inductor magnetographing...

Страница 31: ...m When preparing the device for storage it is recommended to perform maintenance as described in paragraph 3 2 The maximum number of devices in the stack not more than 10 pcs TRANSPORTATION During tra...

Страница 32: ...r acceptance __________ _____________ _________________ position signature full name _________________ year month day Seal Manufacturer JV RIODIN Ukraine 01133 Kiev Leonid Pervomaisky street 9a 26 Pho...

Страница 33: ...by the manufacturer Eddy current magnetographing device Regula 7515M Serial number ____________________ is sold to Seal Seller s name _________________________________________ Date of sale __________...

Страница 34: ......

Страница 35: ......

Страница 36: ...Ukraine 01133 Kiev Leonid Pervomaisky street 9a 26 Phone Fax 38 044 246 4164 38 044 288 0549 E mail riodin kiev gmail com...

Отзывы: