9
CAUTION!
Mechanical mounting precautions:
• The mounting pins must have the correct
dimension.
• The bolts and nuts must be made of a high
quality steel grade.
• No excessive free play in the pins.
• Do not use an excessive torque on the mounting
bolts to prevent from stressing the fixtures.
CAUTION!
The piston rod eye is only allowed to turn 0-90
degrees.
It is not permitted to make excessive turns
on the piston rod
.
WARNING!
If the actuator is used for pull in an application
where personal injury can occur, the following
is valid:
It is the application manufacturer’s
responsibility to incorporate a suitable safety
arrangement, which will prevent personal in-
jury from occurring if the actuator should fail.
WARNING!
REGNER®’s actuators are not designed to be
used in the following applications:
aircrafts and
aerospace, explosive environments, nuclear power
generation and offshore installations.
05.02.
Electrical installation
Standard Actuator
• The actuator voltage must be switched off when
reaching the ends of stroke or during a mid-stroke
overload to avoid causing damage to the actuator.
• Make sure that the switch can handle the maximum
motor current.
Actuator with Electronic Limit Switches (ELS)
• The actuator will automatically switch off when
reaching the ends of stroke or if a mid-stroke
overload occurs.
ELECTRONIC
LIMIT
SWITCHES
Standard connector: MOLEX 39-01-3029
Standard connector MOLEX 39-01-3029
(View From Wire Insertion End)
RA MINI
IN-LINE ACTUATOR SERIES