06. Installation

06.01. Mechanical Installation

To install a REGNER® actuator, simply slip a pin 

through the hole on each end. Mounting pins must 

be parallel to each other to keep the actuator from 

bending and being damaged.

The actuator should be installed so that the force of 

the load is exerted on the center of the rod. Exces-

sive off-center loads may cause bending and lead to 

premature failure.

RECOMMENDED

OTHER

OTHER

To prevent premature wear, make sure that the 

mounting pins are fixed at both ends, are solid, 

and do not have excessive free play. However, the 

actuator must be able to rotate around the pivot 

point of the rod, as this will allow the actuator to 

move freely along the full stroke length, both in the 

development phase and during normal operation. 

Examine the area around the housing and see that 

no components can get trapped and damage the 

application and the actuator.

CAUTION! 

• Mounting pins must have the correct dimensions 

and limited free play.
• Any bolts and nuts used for the installation must 

be made of high-quality steel.
• Do not apply an excessive torque on the mounting 

bolts to avoid stressing the fixtures.

CAUTION! 

• The rod can turn a maximum of 90°.

WARNING!

If the actuator is used in an application that may 

cause personal injury, it is the responsibility of the 

application manufacturer to introduce the necessary 

safety measures to prevent personal injury in case 

of failure. 

WARNING!

REGNER® actuators are not designed to be used in 

the following applications: aircraft, explosive envi-

ronments, nuclear power generators, and offshore 

installations.

Содержание RA-MINI ALU Series

Страница 1: ...RA MINI ALU IN LINE ACTUATOR SERIES User Manual www regner es...

Страница 2: ...l rights reserved Specifications are subject to change without notice It is the responsibility of the user to determine the suitability of REGNER products for a specific application No part of this pu...

Страница 3: ...E ACTUATOR SERIES 3 00 Contents 01 Preface 4 02 Safety 4 03 Declaration of Conformity 5 04 Warranty 6 05 Specifications 6 06 Installation 9 07 Maintenance 10 08 Troubleshooting 11 09 Application Polic...

Страница 4: ...off the main power supply when the actuator is not in use to prevent unintentional operation Do not exert force on the side of the actuator Make sure that the cable cannot be pressed upon pulled or su...

Страница 5: ...electronic products with respect to the restriction of hazardous sub stances In accordance with the provisions of the directives 2014 30 EU OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 26 February...

Страница 6: ...allegedly defective products for testing and verification Any additional warranty obligations for parts replaced free of charge or for any service provided without charge under this warranty shall be...

Страница 7: ...ing current 200 mA Overcurrent prot 116 mA Integrated limit switch Integrated in Limit Switches version Not available in Potenti ometer version Connector Molex 39 01 3029 IP rating IP54 Retracted leng...

Страница 8: ...overcurrent protection feature will cut off the current at 3 A to protect the actuator The overcur rent protection system resets after 10 seconds when activated to enable normal operation 05 06 Elect...

Страница 9: ...ve freely along the full stroke length both in the development phase and during normal operation Examine the area around the housing and see that no components can get trapped and damage the applicati...

Страница 10: ...ion use a fuse between the actuator and the power source Do not work on the actuator or the wiring with the power switched on Wire cross sections To avoid malfunctions due to voltage drops the cross s...

Страница 11: ...orce or runs in smaller steps 1 Excessive load 2 Voltage drop in the cable long cables may affect performance 3 Current cut off due to ex cessive load A Wait for the overcurrent protection system to r...

Страница 12: ...RA MINI ALU IN LINE ACTUATOR SERIES 12...

Страница 13: ...MAGPOTUSERMANUAL Ripoll s 4 17181 Aiguaviva Girona SPAIN Tel 34 972 476 911 Fax 34 972 475 803 info regner es www regner es...

Отзывы: