REGIS T-X-B – Access or time and attendance controller

 

 

 

 

 

10/2016 

Black line 

www.jantar.si 

 
Inputs, outputs and environment 

Inputs: 

Inputs are realized with opto-isolators. The input is active, when 
pulled to ground with an open collector transistor or mechanical 
switch, which is connecting the input pin of the controller to the 
Ground. 

 
Outputs: 

Output has a pre-installed protection diode for an inductive load. It 
is also protected from current overload. The best way is to use a 
0.25A el. strike or a 0.5A el. magnet, which has to be connected to 
the same positive pole (+) as the controller. Connect the negative 
pole (-) to the door strike output (wire 3). When the output is 
active it is pulled to ground. This can be changed with function 5 – 
negate output (for el. magnet). 

 
Environment:

 

Do not install the controller on/in a place, where it can come in 
contact with water. You must assure good cable joints, protected 
against moisture, otherwise corrosion may damage the controller. 
Damage in such cases is not covered by the warranty.  
 

Regis T-1-B reading range: 

The controller has a program algorithm that, at power start, sets 
parameters based on the installation environment, so as to ensure 
an optimal reading range. 

DO NOT 

install the controller directly on 

metal surfaces and/or cover it with a metal cover; it may stop 
working/reading. If you plan to test the controller and move it onto 
different surfaces, then you have to reset it (power off/on) on each 
surface. 

 

Regis T-1-B reading field: 

The controller has a reading card field active over 1/3 of the 
controller.   
If the controller is in vertical position the reading field is on the 
bottom side of the controller. 
If the controller is in horizontal position the reading field is on the 
right side of the controller. 

 

 

ACCESS OR TIME AND ATTENDANCE 
CONTROLLER 

 

Access controller 

As an access controller, it is intended for controlling entries, exits 
and passes of users in the system and controlling sliding doors, 
ramp, el. strike, turning alarm on/off…  It needs to be set with V7 
or CODEKS software.  

 
Time and attendance controller 

As a time and attendance controller, it is intended to register the 
employee’s arrivals and exits from work, lunch break, private and 
business exits, sick leave... It needs to be set with V7 or CODEKS 
software. In software you need to choose option “Time and 
attendance” for controller and reader. Set the software according 
to your requirements (time tables, users...) and send the tables. 
The keypad will serve for choosing different time intervals (private, 
business…). 

 
The controller switches to access or time and attendance 
controller when tables are sent by the software or when it is 
set to mode 4 with function 9. Change the controller’s 
address from 255 to any number between 1 and 254. If you 
have more controllers on the communication line, don’t 
duplicate addresses. Add them one by one on the 
communication line, because every controller has address 
255 by default. 

 

 

 
 
 
 

 
Communication  

Ethernet: 

Connect the controller to the computer through your LAN via 
Ethernet connector. Use at least UTP CAT 5e cable. Adjust network 
settings of the controller using the Codeks Device Manager 
software so that it will function properly in your network. Please 
consult Codeks Device Manager manual. 

 
S - Spider mode  

In the Spider mode the controller can be used as a communication 
converter, from which you can continue RS485 communication line 
to the other controllers. When the controller is reset to the factory 
settings (brainwash), the controller address is set to 254. 

 
RS485: 

Connect the controller to the computer, with one of the power 
supplies, with communication converter, from the Spider family: 
Spider W5-USB, Spider W5-NET, Spider W40+NET.  
 
The RS485 communication bus is used between the controllers and 
Jantar software. Up to 128 controllers can be lined up into one 
communication line. The maximum length of the communication 
line is 1000 cable meters. It is recommended that you use an FTP 
or S-FTP cable. Only a serial connection of controllers in a single 
communication line is allowed. 

Star (parallel) connection is not 

allowed

.  

All shields of S-FTP cables must be wired together and at 

one 

point

 connected to the earth. Individual connections to the earth 

are not allowed. Do not connect the shield of the cable to the 
ground of the controller. 

 
Reset to the factory settings (brainwash): 

When the controller is reset to the factory settings (brainwash), the 
controller address is set to 254.

 

 

 

ORDERING CODES 

REGIS

 [box]-[card]-[software]  

Box:  

T

 

Card:  

– reading frequency 125kHz (cards)  

– reading frequency 13.56MHz (cards)  

Model:   

B

 – Black line

 

 

 

Code 

Description 

REGIS T-1-B 

Standalone or access controller in 

T

 box, 

Frequency 125kHz, for CODEKS software, 
Integrated Ethernet 

REGIS T-3-B 

Standalone or access controller in 

T

 box, 

Frequency 13.56MHz, for CODEKS software, 
Integrated Ethernet 

 
 

OTHER 

Warranty only applies when the controller Regis is used with power 
supply or/and communication converter from the Spider family. 
 
Please read through our warranty and disclaimer statements. 

 

Connection scheme and additional support for the use of this 
product can be found on: 

http://www.jantar.si/forum/en

 

 