background image

INSTRUCTION

i

Read this instruction before installation  
of the product

TG-R6W

1

   

1

2

3

+

-

+

-

Pairing the sensor with the receiver

Look in the receiver instruction (RCW-M) for information on how to 
pair the sensor with the

 

receiver.

Pairing/connection test

The connection to the receiver must be tested before mounting the
sensor.

1. 

Place the receiver and the sensor at the desired locations. 

2. 

Put the receiver into 

Programming 

mode (refer to the RCW-M 

instruction).

3. 

Perform a

 Walk test

: Press the 

Test button

 on the sensor to see if the 

location is within signal range of the receiver. The LED light will indi-
cate if the sensor is paired with the receiver or not. There will also be 
a long beep from the receiver when the sensor is paired successfully.

LED light

3 fl ashes

 (

When 

Test button

 is pressed): 

The sensor is not paired with the receiver.

Flashing

 (

When 

Test button

 is pressed): 

The sensor is paired with the receiver.

Flash every 4 seconds

:

 

Batteries needs to be replaced.

Mounting the sensor

1. 

Use the screw holes in the casing to mount the sensor on the wall

2. 

Snap on the cover

TG-R6W

Wireless outdoor temperature sensor

TG-R6W is a wireless outdoor temperature sensor that monitors tem-
perature and sends a signal to the Regin Modbus receiver 
RCW-M.

Commissioning

The sensor should be placed out of direct sunlight and in a place with 
unobstructed air circulation. 
The sensor must be paired with the receiver RCW-M before it can be 
used.

Installation of batteries

1. 

Open the cover by pressing the locking tabs carefully with a 
screwdriver

2. 

Insert two CR123 3V Lithium batteries

Other functions

Temperature detection

The sensor monitors the temperature at a preset time interval (factory 
setting is 2 minutes), and if the temperature has changed by more 
than ± 1°C it will send a signal to the receiver. If the temperature is 
stable, the sensor will transmit a signal every 95-115 minutes.

Self test

The sensor

 

will automatically send a supervisory signal to the receiver 

at an interval of 95 to 115 minutes to test the signal. 
The receiver will indicate “out of signal” if it has not received the 
signal at a preset interval.

Technical data

Battery   

 

CR123 3V Lithium x 2

Frequency 

 

868 MHz

Operating temperature 

-30...+50°C

Operation humidity  

Max. 85% RH (non-condensing)

Protection class 

 

IP54

Dimensions (HxWxD) 

85 x 90 x 35 mm

Low Voltage Directive (LVD) standards

This product conforms to the requirements of the European Low 
Voltage Directive (LVD) 2014/35/EU through product standards 
EN 60950-1 and +A11, +A1, +A12 and +A2.

EMC emissions & immunity standards

This product conforms to the requirements of the EMC Directive 
2014/30/EU through product standards EN 50130-4, EN 61000-4-2, 
EN 61000-4-3 and +A2.

Effi cient use of the radio frequency spectrum

This product conforms to the requirements of the Effi cient use of the 
radio frequency spectrum, Article 3.2 of 1999/5/EG through the follow-
ing standards: EN 301489-1: V1.9.2, EN 301489-3: V1.6.1, 
EN 300220-2: V2.4.1 and EN 300220-1: V2.4.

RF & human exposure

EN 62479.

RoHS

This product conforms to the Directive 2011/65/EU of the 
European Parliament and of the Council through product standard 
EN 50581:2012.

1

2

8

1

3

D

F

EB 

1

7

EN

Number

Description

1

Battery 

compartments

2

Connection/

Test button

3

LED light

Отзывы: