background image

www.regentlight.co.za

www.regentlight.co.za

3

This product should be installed by a competent person i.e. Qualified electrician.
This product requires a constant stable electrical supply 220V - 240V VAC 50Hz - alternating current.
The product must be regularly maintained, including the replacement of lamps/LED timeously.
This product could be HAZARDOUS if not used correctly, it could cause electric shock, serious bodily harm or death.
This product is not a toy, please keep away from children.
This product may contain small parts that can be swallowed.

Use only the correct light bulbs/LED as stipulated on the carton for the product.
Any modifications of this product after supply will result in the guarantee being void.

Spare parts may become unavailable over time.Items can vary slightly from the picture on the carton
Coastal humidity can affect the longevity of the light fitting over time.
Be sure to follow the steps in the order given.
Read instructions carefully.

Important Safety Instructions

A: 

Loosen and remove the CSK 

     stainless steel screws from the 
     complete fitting. 

B: 

Remove the inner fitting from the 

    outer casing. 

4

A:

 Feed the electrical 

     cable from the inner fitting 
     through to the external cable 
     joint kit. Seal the gland 
     by fastening the gland 
     to the casing. 

B:

 Place the outer casing  

    into the cavity. Adjust the 
    height to finished floor level. 

When installing in cement or paving, 
ensure there is a drain pipe under the 
cavity, under the gravel. 

DRAIN UNDER GRAVEL

A

A

B

B

5

GROUND

PAVING/
CEMENT

Insert the fitting into the outer casing. 
Connect the electrical tail supplied 
from the fitting to the cable joint kit. 
Following the resin instructions on the 
cable joint kit.

Connect the Switched Live (S/A), 
Neutral (N) and Earth (E) cable(s) to 
the terminal block.

SWITCHED  LIVE  –  (Red  or  Brown)  to 
terminal marked L
NEUTRAL  –  (Black  or  Blue)  to  terminal 
marked N
EARTH  –  (Green/Yellow)  to  terminal 
marked E.

TOP VIEW OF ELECTRICAL INSTALLATION

Switch
Wire Red

Neutral loop
Black or Blue

Earth loop
Green/Yellow

Mains to
Luminaire

(L) Brown

(N) Blue

(E) Green/Yellow

4

Pot once junction
is connected, according 
to the instructions for the 
cable joint kit

GROUND

PAVING/CEMENT

Pot once junction
is connected, 
according to the 
instructions for the 
cable joint kit

7

6

Align and fasten the fitting to the 
outer casing with the CSK stainless 
steel screws.  

Ensure the gasket is securely in 
place before fastening the fitting.

87

Switch on power supply.

Inner fitting

Outer casing

A

B

SURGE ARRESTOR

SURGE ARRESTOR

Отзывы: