background image

Regency  Z2510  WarmHearth

6

Unit Dimensions

INSTALLATION

8) NEVER leave children unattended when

there is a fire burning in the fireplace.

9) Allow the fireplace to cool before servicing.

Always shut off any electricity to the fire-
place while working on it.  This will prevent
any possible electrical shock.

10) Regency is not responsible for any

smoking or related problems that may
result from the lack of adequate com-
bustion air.  It is the responsibility of
the installer to ensure that adequate
combustion air has been provided for
the fireplace.

11) Regency Industries Ltd. does not warranty

“smoke free” operation nor are we respon-
sible for inadequate system draft caused
by mechanical systems, general construc-
tion conditions, inadequate chimney heights,
adverse wind conditions and/or unusual
environmental factors or conditions be-
yond our control.

12) DO NOT use a fireplace insert or any other

product not specified by Regency for use
with this fireplace.

13) Never, under any circumstances, install a

fireplace, chimney component or any ac-
cessories, supplied by Regency, that have
visible or suspected physical damage as a
result of handling or transportation.  These
items should be inspected by a Regency
dealer or qualified factory representative to
ensure safe condition.  When in doubt,
consult your Regency dealer.

14) It is recommended that power is supplied to

the terminal block of the unit to allow for the
installation of blower components now or at
a future date.

READ BEFORE YOU INSTALL

THE REGENCY WARMHEARTH

HIGH EFFICIENCY EPA

CERTIFIED FIREPLACE

This installation manual will enable you to make
a safe, efficient and dependable installation of
your fireplace and chimney system.  Please
read and understand these instructions before
beginning your installation.

Do not alter or modify the fireplace or its com-
ponents under any circumstances.  Any mod-
ification or alteration of the fireplace system,
including but not limited to the fireplace, chimney
components and accessories, may void the
warranty, listing and approvals of this system
and could result in an unsafe and potentially
dangerous installation.

PLEASE RETAIN THIS MANUAL FOR

FUTURE REFERENCE.

IMPORTANT:  Please read and follow these
rules for safety.

1) Before starting your fireplace installation,

read these installation instructions careful-
ly to be sure you understand them  in their
entirety. Failure to follow them could cause
a fireplace malfunction resulting in serious
injury and/or property damage.

2) Always check your local building codes.

The installation must comply with all local,
regional and state codes and regulations.

3) This model fireplace must be installed with

one of the chimney systems listed in the
Chimney Section in this manual.  These
systems are intended for use as a residen-
tial type appliance.  The chimney must
always vent to the outside of the building.

4) To ensure a safe fireplace system and to

prevent the build-up of soot and creosote,
inspect and clean the fireplace and chim-
ney prior to use and periodically during the
heating season.

5) Use solid fuel only. DO NOT use artificial

logs containing petroleum products, chem-
ical chimney cleaners, gas logs, gas light-
ers, salt contaminated wood or flame col-
orants in your fireplace. When using com-
pressed sawdust logs use only at 1/3
capacity since these get very hot and
expand.

6) DO NOT use charcoal or coal under any

circumstances.

7) NEVER  use gasoline, gasoline-type lantern

fuel, kerosene, charcoal lighter fluid, or any
liquid to start or “freshen up” a fire in this
fireplace.  Keep any flammable liquid a safe
distance from the fireplace.

DIMENSIONS AND

SPECIFICATIONS

The WarmHearth is a woodburning fireplace
featuring a self-contained heat-circulating sys-
tem and cast-iron door with large viewing
window.  Options available are a Central Heat-
ing System or an Internal Blower. A set of
andirons are installed in the firebox  to properly
position the fire, do not remove them.

Note:  Illustrations shown reflect “typi-

cal” installations with  nominal
dimensions and are for design
and framing reference only.  Actu-
al installations may vary due to
individual design  preferences.
However, always maintain mini-
mum clearances to  combustible
materials and do not violate any
specific installation requirements.

The WarmHearth  fireplace has been tested
and listed by Warnock Hersey Inc. to UL. 127
Standard for U.S. installations  and ULC. S610
standard for Canadian installations.  This unit
is intended for installation in convention-
al homes and buildings  of conventional
construction, not in mobile homes.

This fireplace system is designed for installa-
tion in accordance  with the National Fire
Protection Standard for chimneys,  fireplaces
and solid fuel burning appliances;  NFPA 211
and in  accordance with codes such as the
BOCA Basic National Codes, the Standard
Mechanical Code, Uniform Building Codes,
Canadian National Building Codes or applicable
local codes.

Emissions from burning  wood or gas could
contain chemicals known to the State of
California to  cause cancer, birth defects or
other reproductive harm.

Содержание Z2510L

Страница 1: ...arth High Efficiency EPA Certified Fireplace MODEL Z2510L WarmHearth Fireplace Owners Installation Manual 10 06 04 Tested by Installer Please complete the details on the back cover and leave this manual with the homeowner Homeowner Please keep these instructions for future reference www regency fire com ...

Страница 2: ... you years of trouble free enjoyment This product has been certified by the Environmental Protection Agency of the United States Thismeansthatitmeetsthestricteststandardsinprovidingyouwiththelatestincleanburning technologyandefficiency Specificationsmayvarywidely ConsultwithyourRegencyDealerforlocal considerations Keep those REGENCY FIRES burning ...

Страница 3: ...ling the Outside Air Kit 13 Wiring the WarmHearth 13 Installing the Blower Systems 13 Fan Part Numbers 13 1 Internal Blower with Thermodisc 14 2 External Blower with Thermodisc 14 3 Internal External Blower with Thermodisc 14 Gravity Air Feed Option 14 Installing Your Central Heating System 15 Materials Required 15 Installation 15 Finishing the WarmHearth Completing the Facing 17 Non Self Supporti...

Страница 4: ...each Regency WarmHearth It is located inside the lower louver opening on the left side We have printed a copy of the contents here for your review SAFETY LABEL NOTE Regency units are constantly being improved Check the label on the unit and if there is a difference the label on the unit is the correct one ...

Страница 5: ... inch Flue Pipe 12 HighHeatRefractoryLining PRODUCT DETAILS EPA Certified YES Phase 2 Emissions 5 2 Gms Hr Efficiency DEQ 70 7 BTU HR EPA 10 600 39 500 Flue Size 7 diameter or 8 with Adaptor 000 924 Log Size 22 Weight shipping 715 lbs stripped weight 460 lbs INSTALLATION OPTIONS Blower 150 CFM 2 speed Central Forced Air 433 CFM Blower Heating System Gold Door 24 kt Gold Plated Gold Louvers 24 kt G...

Страница 6: ...ulting in serious injury and or property damage 2 Always check your local building codes The installation must comply with all local regional and state codes and regulations 3 This model fireplace must be installed with one of the chimney systems listed in the Chimney Section in this manual These systems are intended for use as a residen tial type appliance The chimney must always vent to the outs...

Страница 7: ...9 A Furnace Damper Control optional 10 The Masonry Retainer Kit Optional 11 Furnace Blower optional CLEARANCES AND HEIGHT REQUIREMENTS The WarmHearth may be placed on or near construction materials The combustion air kit fire stop spacer and roof flashings not chase flashings may be placed directly on or against NOTE 1 Do not insulate the chase cavity with blown or fill type insulation materials 2...

Страница 8: ...place above the floor a Z type safety strip should be fabricated from 20 gauge galvanized sheet steel and used to protect the front surface of the wood INSTALLATION FRAMING DETAILS Note Ducting is tested at 1 in clearance to framing for the first 6 feet and 1 2 in thereafter and no stand offs are required LOCATION OF FIREPLACE Carefully select the proper location for heat circulation aesthetics ch...

Страница 9: ...ledcloserthanthefireplaceout side facing spacers 3 Fireplace must be anchored to the framing to prevent movement or rocking use wall grips or seismic brackets which have been supplied Theseanglebracketsareinstalled by attaching them to the side of the unit and to the back side of the 2 x 4 or further back on 2 x 6 framing CHIMNEY SYSTEM CONSIDERATIONS Regency s WarmHearth Fireplace is to be in sta...

Страница 10: ...ual taste See Pages 17 to 18 10 Position masonry liner bricks and ceramic fiber insulation in the unit Attach gold louvers glass door spring handles See Page 19 INSTALLING THE STAND OFFS Stand offs are installed to provide reduced temperatures and proper clearances for the safe installation of your product They consist of four 1 in stand offs on the back two 2 in stand offs on each side and one 6 ...

Страница 11: ...mes and excessive heat output The chimney must extend at least 3 ft above its point of penetration of the roof and be at least 2 ft higher than any point on the roof wall or building within 10 ft of it 6 The raincap and storm collar should now be fastened to the top of the chimney Install additional support s as indicated by chim ney manufacturer s instructions result if stand offs are not properl...

Страница 12: ... 5000 13 92 15 08 16 24 17 4 20 88 18 56 23 2 5000 6000 14 40 15 60 16 80 18 0 21 60 19 20 24 0 6000 7000 14 88 16 12 17 36 18 6 22 32 19 84 24 8 7000 8000 15 36 16 64 17 92 19 2 23 04 20 48 25 6 8000 9000 15 84 17 16 18 48 19 8 23 76 21 12 26 4 9000 10000 16 32 17 68 19 04 20 4 24 48 21 76 27 2 3 Chimney Maintenance It is important that you inspect your chimney regularly and keep it clean If you ...

Страница 13: ...ng the flange on the fireplace side Duct must be secured by screws or clamp Outside Air Inlet must be 6 ft below the chimney termination point WIRING THE WARMHEARTH Field wire main power supply to fireplace for fan kit All electrical connections should only be performed by a licensed certified electrician INSTALLATION OPTION 1 Internal Blower with Thermo Disc The thermodisc provides the user with ...

Страница 14: ... cover A on top of the unit 2 Take the connector collar and rotate it in the holetocutthrough4 ofinsulation Removethe insulation from pipe 3 Remove the screws on the lower cover Vent cover B and slide it back under the insulation 4 Slide the connector collar into the flex duct and secure with an adjustable clamp FANPARTNUMBERS The parts listed below are available from Re gency Please see your Rege...

Страница 15: ... 4 x 7 3 4 opening is required to fit the frame that is supplied The vent must be installed in the chase and should be within 12 of the floor WARNING Lower air vent MUST be installed in all applications other wise serious overheating of the chase may result 9 Fasten the block off plate to the Warm Hearth using the existing holes that normal ly secure the louvers using the louver screws Make sure t...

Страница 16: ...replace In a 2 story home one good location would be in the ceiling of the basement because you must be able to access it for oiling and replacement Note The blower can be installed al most anywhere in the home How ever some thought should be put into the planning to ensure blow er noise is kept away from rooms that want quiet Length of runs should be kept to a minimum to conserve space and minimi...

Страница 17: ...aaaaaaa Framing Metal Edging Extend unit past studs so it is flush with sheeting Drill Tap screws INSTALLATION FINISHING THE WARMHEARTH Completing the Facing Facing materials must be thin veneer non self supporting facades or self supporting facades If you are installing a thin veneer facade the Regency Masonry Retainer Kit Part 000 920 is recommended All facades must be Non Combustible such as br...

Страница 18: ...ind Top mesh C so that it covers the stand off and will prevent mortar from falling through the mesh 8 Put the door on the unit and check that the veneer on the door hinge side does not interfere with the door swing 9 Use washers and screw top mesh C to top of grill frame This is attached with the top edge of the grill frame on piece B 10 Now fasten mesh to wall sheathing and blend in 11 Use only ...

Страница 19: ...ng handle onto the handle bar LATCH ADJUSTMENT The door latch may require adjustment as the door gasket material compresses after a few fires Removal of the spacer washer shown in the diagram below will allow the latch to be moved closer to the door frame causing a tighter seal Remove and replace the nuts washer and spacer as shown SECONDARY AIR TUBE INSTALLATION 1 Slideairtubeintotheholeontheleft...

Страница 20: ...xists Burning the stove at a very high temperature the first few times may damage the paint Burn fires at a moderate level the first few days 8 For those units installed at higher eleva tions drafting problems may occur Consult an experienced dealer on methods of in creasing your draft Follow the Flue Height Chart Table 1 page 12 9 Some cracking and popping noises may be experienced during the hea...

Страница 21: ...tion Top Heat Shield 48 000 532 Standoff Top Assembly 50 000 127 Standoff Side 51 820 100 Standoff Back 54 000 910 Hearth Extension Optional 000 914 Black Louver set 60 Black Louver Assy Top 61 Black Louver Assy Bottom 000 916 Gold Louver set 62 Gold Louver Assy Top 63 Gold Louver Assy Bottom 68 836 175 Insulation Top Standoff Assy 82 000 927 Thermodisc Kit with wires Optional 83 000 201 Terminal ...

Страница 22: ...ssembly 16 846 570 Med Density Door Gasket Kit 17 846 918 Hinge Caps 2 set 19 948 101 Spring Handle Large 69 836 171 Baffle Insulation 70 Globe 71 Retainer Post 72 902 108 Brick Bottom 73 902 107 Brick Back Right 74 902 106 Brick Back Left 75 902 112 Brick Side Left 76 902 113 Brick Side Right 77 836 132 Insulation Bottom Brick 78 836 133 Insulation Side Brick 79 836 131 Insulation Back Brick 80 0...

Страница 23: ... will not be liable for results or costs of workmanship from unauthorized service persons or dealers At all times FPI reserves the right to inspect product in the field which is claimed to be defective All claims must be submitted to FPI by authorized selling dealers It is essential that all submitted claims provide all of the necessary information including customer name purchase date serial type...

Страница 24: ...____________________________ Printed in Canada Regency fireplace products are designed with reliability and simplicity in mind In addition our internal Quality Assur ance Team carefully inspects each unit thoroughly before it leaves our door Fireplace Products Internation al Ltd is pleased to extend this Limited Lifetime Warranty to the original purchaser of a Regency Product See the inside back c...

Отзывы: