uous floor or platform for support and to pre-
vent cold air from entering the room from under
the fireplace, if against an outside wall.

The fireplace may be positioned and then the
framing built around  it, or the framing may be
constructed and the fireplace  positioned into
the opening.

The minimum ceiling height is 7 feet. When the
unit is raised 4 inches above the floor the
Regency Hearth Extension (Part# 000-910) is
not required. A suitable non-combustible hearth
pad is mandatory in all  installations.

INSTALLING THE

CHIMNEY SYSTEM

Following are a set of general guidelines for
installation of  the chimney system. The more
detailed installation manual supplied with the
specific chimney system must be followed.

1) Using standard construction framing tech-

niques,  construct the opening for the chim-
ney route up through the ceiling(s) and  roof
or through an outside chase.   Framing must
maintain adequate minimum air space clear-
ance at all  times.

CAUTION:  Allow a minimum 2 in. chimney
air space or as specified by the owner's
manual for the chimney, to combustible
framing members throughout vertical or
offset chimney installation.

2) Attach anchor plate/fireplace adaptor to

the top of the fireplace.  It is important that
a tight seal be made with  this part and the
unit’s collar. This must be purchased with
the chimney system.

3) Install firestop, radiation shield, or attic insu-

lation  shield as required at each floor
penetration. See Table 1. Check chimney
manufacturer's framing opening sizes to
allow for correct  clearances. All parts must
be listed.

4) The roof flashing should be installed making

sure that alignment is correct with openings
below.

5) Chimney lengths may now be added until

the required height is reached. A minimum
flue height of 16 ft. from the floor (or 12 ft.
from the top of the unit) is mandatory.
Please refer to Table 2 for Flue Heights:

The performance of your unit is governed
to a very large extent by  the chimney
system. Too short a chimney can produce
poor  drafting which in turn can cause
difficult start-up, dirty glass,  smoking out
door and even reduced heat output. Too tall
a chimney  may prompt excessive draft
which can result in very short burn  times

and excessive heat output. The chimney
must extend at  least 3 ft. above its point of
penetration of the roof and be at least  2 ft.
higher than any point on the roof, wall, or
building within 10 ft. of it.

6) The raincap and storm collar should now be

fastened to the top of the  chimney.  Install
additional support(s) as indicated by chim-
ney manufacturer's instructions.

result if stand-offs are not properly
installed.

INSTALLATION

IMPORTANT: Insulation extends for-
ward to seal against the back of the
WarmHearth masonry or non-com-
bustible face.

SET THE

WARMHEARTH

INTO POSITION

1) Estimate the total weight of the fireplace

system and  surround materials such as
brick, stone, etc., to be installed.   Shipping
weight is 715 lbs. and stripped weight is
460 lbs.  Stripped weight refers to the
weight of the product with bricks, door and
any accessories removed.

2) Measure the square footage of the floor

space to be occupied  by the system,
surrounds and hearth extensions.

3) Note the floor construction, i.e. 2 x 10’s, (51

x 250 mm), single or double joists, type and
thickness of floor boards and consult your
local building code to determine if you need
additional support.

4) Remove door, firebox bricks, louvers etc.

Note:  Set aside Gold doors and louvers

away from harsh chemicals and
away from abrasive materials to
avoid damage, e.g. muriatic acid
for masonry wash will strip the
gold plate on the door.  Firebricks
are fragile and should be handled
with caution.

The fireplace may be installed directly on a
combustible floor or raised on a platform of an
appropriate height. Do not place fireplace on
carpeting, vinyl or other soft floor coverings. It
may, however, be placed on flat wood, ply-
wood, particle board or other hard surfaces.
Be sure the fireplace rests on a solid  contin-

SPECIAL NOTES:

1) Negative Pressure In The House. When

there is no fire in your unit there still should
be sufficient draft to draw smoke from a
burning piece of paper held under the baf-
fle.  If your installation is correct, smoke will
go up the flue.  If however, there is a
problem with your installation, cold air may
be coming down the flue into the room. This
may be the case if your unit smokes on
start-up with the door open, until the unit
heats up.  To overcome this problem, try
closing an upstairs window and open a
nearby window to pressurize the house.
Note: the door can be open briefly to start
your fire but must be closed during reg-

Содержание Z2510L

Страница 1: ...arth High Efficiency EPA Certified Fireplace MODEL Z2510L WarmHearth Fireplace Owners Installation Manual 10 06 04 Tested by Installer Please complete the details on the back cover and leave this manual with the homeowner Homeowner Please keep these instructions for future reference www regency fire com ...

Страница 2: ... you years of trouble free enjoyment This product has been certified by the Environmental Protection Agency of the United States Thismeansthatitmeetsthestricteststandardsinprovidingyouwiththelatestincleanburning technologyandefficiency Specificationsmayvarywidely ConsultwithyourRegencyDealerforlocal considerations Keep those REGENCY FIRES burning ...

Страница 3: ...ling the Outside Air Kit 13 Wiring the WarmHearth 13 Installing the Blower Systems 13 Fan Part Numbers 13 1 Internal Blower with Thermodisc 14 2 External Blower with Thermodisc 14 3 Internal External Blower with Thermodisc 14 Gravity Air Feed Option 14 Installing Your Central Heating System 15 Materials Required 15 Installation 15 Finishing the WarmHearth Completing the Facing 17 Non Self Supporti...

Страница 4: ...each Regency WarmHearth It is located inside the lower louver opening on the left side We have printed a copy of the contents here for your review SAFETY LABEL NOTE Regency units are constantly being improved Check the label on the unit and if there is a difference the label on the unit is the correct one ...

Страница 5: ... inch Flue Pipe 12 HighHeatRefractoryLining PRODUCT DETAILS EPA Certified YES Phase 2 Emissions 5 2 Gms Hr Efficiency DEQ 70 7 BTU HR EPA 10 600 39 500 Flue Size 7 diameter or 8 with Adaptor 000 924 Log Size 22 Weight shipping 715 lbs stripped weight 460 lbs INSTALLATION OPTIONS Blower 150 CFM 2 speed Central Forced Air 433 CFM Blower Heating System Gold Door 24 kt Gold Plated Gold Louvers 24 kt G...

Страница 6: ...ulting in serious injury and or property damage 2 Always check your local building codes The installation must comply with all local regional and state codes and regulations 3 This model fireplace must be installed with one of the chimney systems listed in the Chimney Section in this manual These systems are intended for use as a residen tial type appliance The chimney must always vent to the outs...

Страница 7: ...9 A Furnace Damper Control optional 10 The Masonry Retainer Kit Optional 11 Furnace Blower optional CLEARANCES AND HEIGHT REQUIREMENTS The WarmHearth may be placed on or near construction materials The combustion air kit fire stop spacer and roof flashings not chase flashings may be placed directly on or against NOTE 1 Do not insulate the chase cavity with blown or fill type insulation materials 2...

Страница 8: ...place above the floor a Z type safety strip should be fabricated from 20 gauge galvanized sheet steel and used to protect the front surface of the wood INSTALLATION FRAMING DETAILS Note Ducting is tested at 1 in clearance to framing for the first 6 feet and 1 2 in thereafter and no stand offs are required LOCATION OF FIREPLACE Carefully select the proper location for heat circulation aesthetics ch...

Страница 9: ...ledcloserthanthefireplaceout side facing spacers 3 Fireplace must be anchored to the framing to prevent movement or rocking use wall grips or seismic brackets which have been supplied Theseanglebracketsareinstalled by attaching them to the side of the unit and to the back side of the 2 x 4 or further back on 2 x 6 framing CHIMNEY SYSTEM CONSIDERATIONS Regency s WarmHearth Fireplace is to be in sta...

Страница 10: ...ual taste See Pages 17 to 18 10 Position masonry liner bricks and ceramic fiber insulation in the unit Attach gold louvers glass door spring handles See Page 19 INSTALLING THE STAND OFFS Stand offs are installed to provide reduced temperatures and proper clearances for the safe installation of your product They consist of four 1 in stand offs on the back two 2 in stand offs on each side and one 6 ...

Страница 11: ...mes and excessive heat output The chimney must extend at least 3 ft above its point of penetration of the roof and be at least 2 ft higher than any point on the roof wall or building within 10 ft of it 6 The raincap and storm collar should now be fastened to the top of the chimney Install additional support s as indicated by chim ney manufacturer s instructions result if stand offs are not properl...

Страница 12: ... 5000 13 92 15 08 16 24 17 4 20 88 18 56 23 2 5000 6000 14 40 15 60 16 80 18 0 21 60 19 20 24 0 6000 7000 14 88 16 12 17 36 18 6 22 32 19 84 24 8 7000 8000 15 36 16 64 17 92 19 2 23 04 20 48 25 6 8000 9000 15 84 17 16 18 48 19 8 23 76 21 12 26 4 9000 10000 16 32 17 68 19 04 20 4 24 48 21 76 27 2 3 Chimney Maintenance It is important that you inspect your chimney regularly and keep it clean If you ...

Страница 13: ...ng the flange on the fireplace side Duct must be secured by screws or clamp Outside Air Inlet must be 6 ft below the chimney termination point WIRING THE WARMHEARTH Field wire main power supply to fireplace for fan kit All electrical connections should only be performed by a licensed certified electrician INSTALLATION OPTION 1 Internal Blower with Thermo Disc The thermodisc provides the user with ...

Страница 14: ... cover A on top of the unit 2 Take the connector collar and rotate it in the holetocutthrough4 ofinsulation Removethe insulation from pipe 3 Remove the screws on the lower cover Vent cover B and slide it back under the insulation 4 Slide the connector collar into the flex duct and secure with an adjustable clamp FANPARTNUMBERS The parts listed below are available from Re gency Please see your Rege...

Страница 15: ... 4 x 7 3 4 opening is required to fit the frame that is supplied The vent must be installed in the chase and should be within 12 of the floor WARNING Lower air vent MUST be installed in all applications other wise serious overheating of the chase may result 9 Fasten the block off plate to the Warm Hearth using the existing holes that normal ly secure the louvers using the louver screws Make sure t...

Страница 16: ...replace In a 2 story home one good location would be in the ceiling of the basement because you must be able to access it for oiling and replacement Note The blower can be installed al most anywhere in the home How ever some thought should be put into the planning to ensure blow er noise is kept away from rooms that want quiet Length of runs should be kept to a minimum to conserve space and minimi...

Страница 17: ...aaaaaaa Framing Metal Edging Extend unit past studs so it is flush with sheeting Drill Tap screws INSTALLATION FINISHING THE WARMHEARTH Completing the Facing Facing materials must be thin veneer non self supporting facades or self supporting facades If you are installing a thin veneer facade the Regency Masonry Retainer Kit Part 000 920 is recommended All facades must be Non Combustible such as br...

Страница 18: ...ind Top mesh C so that it covers the stand off and will prevent mortar from falling through the mesh 8 Put the door on the unit and check that the veneer on the door hinge side does not interfere with the door swing 9 Use washers and screw top mesh C to top of grill frame This is attached with the top edge of the grill frame on piece B 10 Now fasten mesh to wall sheathing and blend in 11 Use only ...

Страница 19: ...ng handle onto the handle bar LATCH ADJUSTMENT The door latch may require adjustment as the door gasket material compresses after a few fires Removal of the spacer washer shown in the diagram below will allow the latch to be moved closer to the door frame causing a tighter seal Remove and replace the nuts washer and spacer as shown SECONDARY AIR TUBE INSTALLATION 1 Slideairtubeintotheholeontheleft...

Страница 20: ...xists Burning the stove at a very high temperature the first few times may damage the paint Burn fires at a moderate level the first few days 8 For those units installed at higher eleva tions drafting problems may occur Consult an experienced dealer on methods of in creasing your draft Follow the Flue Height Chart Table 1 page 12 9 Some cracking and popping noises may be experienced during the hea...

Страница 21: ...tion Top Heat Shield 48 000 532 Standoff Top Assembly 50 000 127 Standoff Side 51 820 100 Standoff Back 54 000 910 Hearth Extension Optional 000 914 Black Louver set 60 Black Louver Assy Top 61 Black Louver Assy Bottom 000 916 Gold Louver set 62 Gold Louver Assy Top 63 Gold Louver Assy Bottom 68 836 175 Insulation Top Standoff Assy 82 000 927 Thermodisc Kit with wires Optional 83 000 201 Terminal ...

Страница 22: ...ssembly 16 846 570 Med Density Door Gasket Kit 17 846 918 Hinge Caps 2 set 19 948 101 Spring Handle Large 69 836 171 Baffle Insulation 70 Globe 71 Retainer Post 72 902 108 Brick Bottom 73 902 107 Brick Back Right 74 902 106 Brick Back Left 75 902 112 Brick Side Left 76 902 113 Brick Side Right 77 836 132 Insulation Bottom Brick 78 836 133 Insulation Side Brick 79 836 131 Insulation Back Brick 80 0...

Страница 23: ... will not be liable for results or costs of workmanship from unauthorized service persons or dealers At all times FPI reserves the right to inspect product in the field which is claimed to be defective All claims must be submitted to FPI by authorized selling dealers It is essential that all submitted claims provide all of the necessary information including customer name purchase date serial type...

Страница 24: ...____________________________ Printed in Canada Regency fireplace products are designed with reliability and simplicity in mind In addition our internal Quality Assur ance Team carefully inspects each unit thoroughly before it leaves our door Fireplace Products Internation al Ltd is pleased to extend this Limited Lifetime Warranty to the original purchaser of a Regency Product See the inside back c...

Отзывы: