Vertical Venting with Two (2) 90° Elbows 
- Initial vertical section.

Two 45° elbows = One 90° elbow

Option

V

H

V+ V1

Maximum total pipe: length, of 
all sections, must not exceed 
30 feet.  
Total horizontal sections must 
not exceed 8 feet.

Minimum of 1 foot between 
90° elbows is required.

A)

1’ Min.

4’ Max.

2’ Min.

B)

2’ Min.

5’ Max.

3’ Min.

C)

3’ Min.

6’ Max.

4’ Min.

D)

4’ Min.

7’ Max.

5’ Min.

E)

5’ Min.

8’ Max.

6’ Min.

Vertical Venting with Two (2) 90° Elbows 
- Initial horizontal section.

Two 45° elbows = One 90° elbow

Option

H + H1

V

Maximum total pipe: length, of 
all sections, must not exceed 
30 feet.  
Total horizontal sections must 
not exceed 6 feet.

Minimum of 1 foot between 
90° elbows is required.

A)

2’ Max.

2’ Min.

B)

3’ Max.

3’ Min.

C)

4’ Max.

4’ Min.

D)

5’ Max.

5’ Min.

E)

6’ Max.

6’ Min.

Vertical Venting with Three (3) 90° 
Elbows - Initial vertical section.

Two 45° elbows = One 90° elbow

Option

V

H + H1

V+ V1

Maximum total pipe: length, of 
all sections, must not exceed 
30 feet.  
Total horizontal sections must 
not exceed 8 feet.

Minimum of 1 foot between 
90° elbows is required.

A)

2’ Min.

3’ Max.

4’ Min.

B)

3’ Min.

4’ Max.

6’ Min.

C)

4’ Min.

5’ Max.

7’ Min.

D)

5’ Min.

6’ Max.

8’ Min.

E)

6’ Min.

7’ Max.

9’ Min.

F)

7’ Min.

8’ Max.

10’ Min.

Vertical Venting with Three (3) 90° 
Elbows - Initial horizontal section.

Two 45° elbows = One 90° elbow

Option

H

V

H + H1

V+ V1

Maximum total pipe: 
length, of all sections, 
must not exceed 30 
feet.  
Total horizontal sections 
m u s t   n o t   e x c e e d   7 
feet.

Minimum of 1 foot 
between 90° elbows 
is required.

A)

1’ Max.

1’ Min.

3’ Max.

3’ Min.

B)

2’ Max.

2’ Min.

4’ Max.

5’ Min.

C)

3’ Max.

3’ Min.

5’ Max.

7’ Min.

D)

4’ Max.

4’ Min.

6’ Max.

9’ Min.

E)

5’ Max.

5’ Min.

7’ Max.

11’ Min.

P48 Gas Fireplace

65

June 2007 Regency Product Specifi cations Book

Gas Fireplaces

Gas Fir

eplaces

Содержание P48-LP2

Страница 1: ...eight w Standoff 47 1193mm E Unit Depth 23 1 4 324mm F Firebox Height 40 1016mm Framing Dimensions Description P33 G Framing Width 48 1 2 1232mm H Framing Height 47 1 2 1207mm I Framing Depth 29 3 4 756mm Vertical Rise 26 1 4 667mm No Vertical Rise J Corner Wall Length 57 5 8 1464mm K Corner Facing Wall Width 81 1 2 2070mm L Framed Chase Ceiling N A Vertical Rise 50 1270mm No Vertical Rise M Vent ...

Страница 2: ...ojection 3 1 1 2 Mantel Leg Clearances Combustible mantel leg clearances as per diagram below Clearances are from the finished edge of the unit Maximum 1 projection at 3 minimum clearance Mantel Clearances A B C D Front 41 1041mm 15 381mm 10 254mm 8 203mm P48 Gas Fireplace WARNING Failure to maintain required clearances is a major cause of chimney related fires Installation of this fireplace must com...

Страница 3: ...Flex Horizontal Terminations Only These venting systems in combination with the P48 Direct Vent Gas Fireplace have been tested and listed as a direct vent heater system by Warnock Hersey The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram FPI Direct Vent Flex System Termination Kits include all the parts needed to install the P48 using a flexi...

Страница 4: ... shaded area 6 8 2 0 4 10 12 in the diagram shows allowable venting configurations using 45 and one 90 elbow Vent must be supported at offsets Horizontal sections must be supported every 3 feet Firestops are required at each floor level and whenever passing through a wall Maintain clearances to combustible materials Minimum of 1 pipe section between elbows Note Must use optional flue adapter when us...

Страница 5: ... Min Vertical Venting with Three 3 90 Elbows Initial vertical section Two 45 elbows One 90 elbow Option V H H1 V V1 Maximum total pipe length of all sections must not exceed 30 feet Total horizontal sections must not exceed 8 feet Minimum of 1 foot between 90 elbows is required A 2 Min 3 Max 4 Min B 3 Min 4 Max 6 Min C 4 Min 5 Max 7 Min D 5 Min 6 Max 8 Min E 6 Min 7 Max 9 Min F 7 Min 8 Max 10 Min ...

Страница 6: ...ote Must use optional flue adapter Part 770 994 when using Rigid Pipe Maintain clearances to combustibles Horizontal vent must be supported every 3 feet Firestops are required at each floor level and whenever passing through a wall A vent guard should be used whenever the termination is lower than the specified minimum or as per local codes Note FPIDirectVentSystem Flex isonlyapprovedforhorizontal te...

Страница 7: ...orizontal Venting with Three 3 90 Elbows Initial vertical section Two 45 elbows One 90 elbow Option V H V V1 H H1 Maximum total pipe length of all sections must not exceed 30 feet Total horizontal sections must not exceed 8 feet Minimum of 1 foot between 90 elbows is required A 2 Min 1 Max 3 Min 4 Max B 3 Min 2 Max 4 Min 5 Max C 4 Min 3 Max 6 Min 6 Max D 5 Min 4 Max 8 Min 7 Max E 6 Min 5 Max 10 Mi...

Отзывы: