P36 - P36D  Zero Clearance Direct Vent Gas Fireplace

Model

P36-NG4

P36-LP4

P36D-NG1

P36D-LP1

Fuel Type

Natural Gas

Propane

Natural Gas

Propane

Minimum Supply 
Pressure

5” W.C. 

(1.25 kPa)

12” W.C. 

(3.00 kPa)

5” W.C. 

(1.25 kPa)

12” W.C. 

(3.00 kPa)

Manifold 
Pressure - High

3.8” W.C. 

(0.95 kPa)

11” W.C. 

(2.74 kPa)

3.8” W.C. 

(0.95 kPa)

11” W.C. 

(2.74 kPa)

Manifold 
Pressure - Low

1.1” W.C. 

(0.27 kPa)

2.9” W.C. 

(0.72 kPa)

1.1” W.C. 

(0.27 kPa)

2.9” W.C. 

(0.72 kPa)

Orifi ce Size

#37 DMS

#52 DMS

#37 DMS

#52 DMS

Minimum Input 

15,500 BTU/h 

(4.54 kW) 

15,000 BTU/h 

(3.96 kW) 

15,500 BTU/h 

(4.54 kW) 

15,000 BTU/h 

(3.96 kW) 

Maximum Input

30,000 BTU/h 

(8.79 kW) 

30,000 BTU/h 

(8.79 kW) 

30,000 BTU/h 

(8.79 kW) 

30,000 BTU/h 

(8.79 kW) 

Vent Sizing

4” Inner / 6 5/8” 

Outer

4” Inner / 6 5/8” 

Outer

4” Inner / 6 5/8” 

Outer

4” Inner / 6 5/8” 

Outer

A

D

C

F

E

A

B

Unit Dimensions

Description

P36

P36D

A

Front Face Width

36” (914mm)

36” (914mm)

B

Rear Firebox Width

33-1/4” (838mm)

33-1/4” (838mm)

C

Front Face Height

30-1/2” (775mm)

30-1/2” (775mm)

D

Height w/ Standoff

36” (914mm)

37” (940mm)

E

Unit Depth

12-3/4” (324mm)

17-1/8” (435mm)

F

Height to Vent

32-1/2” (826mm)

32-1/2” (826mm)

Framing Dimensions

Description

P36

P36D

G

Framing Width*

36-1/4” (921mm)

36-1/4” (921mm)

H

***

Framing Height*  

***

36-1/4” (921mm)

***

37-1/4” (946mm)

***

I

Framing Depth*

12-3/4” (324mm)

17-1/8” (435mm)

J

Corner Wall Length

42-7/16” (1078mm)

48” (1219mm)

K

C o r n e r   F a c i n g   Wa l l 
Width

60” (1524mm)

68” (1727mm)

L

Framed Chase Ceiling

46” (1168mm)

46-1/2” (1181mm)

M

Vent Centerline Height

40-1/2” (1029mm)

40-1/2” (1029mm)

N

Gas Connection Height

2” (51mm)

2” (51mm)

O

Gas Connection Inset

3-1/2” (89mm)

3-1/2” (89mm)

P

Gas Connection Width

4” (102mm) 

4” (102mm) 

G

H

I

K

J

L

O P

N

M

10" (254mm)

dia. Hole through

wall Vent.

Opening for gas

connection

Top Header

Drywall

(or other

facing)

*

If using the Barcelona Surround, Kensington, Balmoral, or 

Tripoli Screen Door  please note that framing and facing must 
be non combustible (12” on top and 6” on both sides) and  that 
the Barcelona is only approved  for installation with a single 
sidewall.

P36 - P36D Gas Fireplace

Approved Venting Systems

Flex Vent Systems:

FPI AstroCap™ Flex Vent

Rigid Pipe Vent Systems:

Simpson Dura-Vent® Direct Vent GS
American Metal Products Ameri Vent  
Security Secure Vent® 
Selkirk Direct-Temp.

***

Important:  Framing height requires consideration of the hearth 

depth.   Dimension H = H + the thickness of installed hearth.

Please refer to Page 11 (Exterior Vent Terminations) 

for additional guidelines on vent locations.

35

June 2007 Regency Product Specifi cations Book

Gas Fireplaces

Gas Fir

eplaces

Содержание P36-NG4

Страница 1: ... 4 921mm 36 1 4 921mm H Framing Height 36 1 4 921mm 37 1 4 946mm I Framing Depth 12 3 4 324mm 17 1 8 435mm J Corner Wall Length 42 7 16 1078mm 48 1219mm K Corner Facing Wall Width 60 1524mm 68 1727mm L Framed Chase Ceiling 46 1168mm 46 1 2 1181mm M Vent Centerline Height 40 1 2 1029mm 40 1 2 1029mm N Gas Connection Height 2 51mm 2 51mm O Gas Connection Inset 3 1 2 89mm 3 1 2 89mm P Gas Connection ...

Страница 2: ...projection 3 1 1 2 8 Single Sidewall when using the Barcelona Surrround Mantel Clearances A B C D with Flush Glass or Hampton Cast 30 1 2 778mm 14 356mm 10 254mm 7 178mm with Bay Option 30 1 2 778mm 13 330mm 10 254mm 7 178mm with Flush Glass and Barcelona Surround 30 1 2 778mm 17 432mm 12 305mm 8 203mm with Tripoli Screen Door Kensington or Balmoral Front 30 1 2 778mm 20 508mm N A 12 305mm P36 P36...

Страница 3: ...pe purchased from Regency may be used for Flex installations 3 Horizontal sections must be supported every 3 feet Alternate Horizontal Termination Caps Alternate Horizontal Riser Vent Terminal Part 640 530 P Snorkel Terminations Snorkel Terminations For installations requiring a vertical rise on the exterior of the building 14 inch and 36 inch tall Snorkel Terminations and the Riser Vent are avail...

Страница 4: ...ible materials Minimum of 1 pipe section between elbows Note Must use optional flue adapter when using Rigid Pipe Part 510 994 Maximum 40 ft 12 2m Minimum 10 6 3 2m Minimum 8 6 2 6m Max 10 3m centerline to centerline Minimum 12 305mm Maximum 27 ft 8 2m 0 2 4 6 40 8 10 12 14 16 18 20 22 24 26 28 30 Vertical Height Feet 32 34 36 38 6 8 2 0 4 10 12 12 16 18 14 Rigid Pipe Adapter Part 510 994 Pipe Leng...

Страница 5: ...x 6 Min F 5 Min 8 Max 7 Min Vertical Venting with Three 3 90 Elbows Two 45 elbows One 90 elbow Option V H H1 V V1 Maximum total pipe length of all sections must not exceed 30 feet Total horizontal sections must not exceed 8 feet Minimum of 1 foot between 90 elbows is required A 0 Min 2 Max 2 Min B 1 Min 2 Max 3 Min C 2 Min 3 Max 4 Min D 3 Min 4 Max 6 Min E 4 Min 5 Max 7 Min F 5 Min 6 Max 8 Min G 6...

Страница 6: ... 10 12 14 16 18 20 22 24 26 28 30 in the diagram shows allowable combinations when installing a P36 The darker shaded area in the diagram shows additional allowable combinations when installing a P36D Note Must use optional flue adapter Part 510 994 when using Rigid Pipe Maintain clearances to combustibles Horizontal vent must be supported every 3 feet Firestops are required at each floor level and ...

Страница 7: ... Venting with Three 3 90 Elbows Two 45 elbows One 90 elbow Option V H V V1 H H1 Maximum total pipe length of all sections must not exceed 30 feet Total horizontal sections must not exceed 8 feet Minimum of 1 foot between 90 elbows is required A 0 Min 1 Max 1 Min 2 Max B 1 Min 2 Max 3 Min 3 Max C 2 Min 2 Max 5 Min 4 Max D 3 Min 2 Max 7 Min 5 Max E 4 Min 3 Max 9 Min 6 Max F 5 Min 4 Max 10 Min 7 Max ...

Страница 8: ...ear Adapter Kit which contains the following Co linear Flex Adapter Outer Pipe Inner Pipe Adapter 510 994 Flue Adapter 945 45º Elbow Alternate Approved Caps 980 Vertical Termination Cap 991 High Wind Cap 923GK 3 Co linear Adapter with flashing The shaded area in the diagrams show the allowable vertical terminations Please refer to Page 11 Exterior Vent Terminations for additional guidelines on vent...

Отзывы: