background image

WARNING:  
If the information in these instructions are not followed exactly, 
a  fi re or explosion may result causing property damage, 
personal injury or loss of life. 

FOR YOUR SAFETY
Do not store or use gasoline or other fl ammable vapors and 
liquids in the vicinity of this or any other appliance.

Installation and service must be performed by a qualifi ed 
installer, service agency or the gas supplier.

FOR YOUR  SAFETY
What to do if you smell gas:

 

Do not try to light any appliance

 

Do not touch any electrical switch: 
do not use any phone in your 
building.

 

Immediately call your gas supplier 
from a neighbour's phone. Follow 
the gas supplier's instructions.

 

If you cannot reach your gas 
supplier, call the fi re department.

FPI FIREPLACE PRODUCTS INTERNATIONAL LTD.  6988 Venture St., Delta, BC  Canada, V4G 1H4

919-125

Regency P33CE 

Gas Fireplace

06/12/12

Owners & 

Installation Manual

www.regency-fi re.com

Tested by:

Installer:

 

Please complete the details on the back cover 

and leave this manual with the homeowner.

Homeowner: 

Please keep these instructions for future reference.

MODEL: P

3

3CE-NG Natural Gas

        P

3

3CE-LP Propane

Содержание P33CE-LP

Страница 1: ...o light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department FPI FIREPLACE PRODUCTS INTERNATIONAL LTD 6988 Venture St Delta BC Canada V4G 1H4 919 125 Regency P33CE Gas Fireplace 06 12 12 Owners Installati...

Страница 2: ... with all the warmth and charm of a wood fireplace at the flick of a switch The P33CE has been approved by Warnock Hersey Intertek for both safety and efficiency As it also bears our own mark it promises to provide you with economy comfort and security for many trouble free years to follow Please take a moment now to acquaint yourself with these instructions and the many features of your Regency F...

Страница 3: ...the current National Fuel Gas Code ANSI Z223 1 and the current National Electrical Code ANSI NFPA 70 in the U S A and the current CAN CGA B149 Gas Installation Code and the current Canadian Electrical Code CSA C22 1 in Canada The appliance when installed must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 or t...

Страница 4: ... 8 Locating your fireplace 8 Duct System Option 8 Unit Dimensions 9 Clearances 10 Combustible Mantels 11 Mantel Leg Clearances 12 Framing Dimensions 13 Framing Finishing 14 Venting Introduction 16 Exterior Vent Termination Locations 17 Regency Direct Vent flex System 18 Installation Procedures 19 Rigid Pipe Venting Systems 20 4 x 6 5 8 Rigid Pipe Cross Reference Chart 21 Rigid Pipe Venting Arrange...

Страница 5: ...onstruction and Safety Standard Title 24 CFR Part 3280 in the United States or when such a standard is not applicable ANSI NCSBCSA225 1 NFPA501A Manufactured Home Installations Standard This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket permanently located manufactured mobile home where not prohibited by local codes See owner s ...

Страница 6: ...y in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless upon inspection...

Страница 7: ...repairs to this appliance should be done by a qualified service person Aprofessional service person should be called to inspect this appliance annually Make it a practice to have all of your gas appliances checked annually 13 Do not slam shut or strike the glass door 14 Under no circumstances should any solid fuels wood paper cardboard coal etc be used in this appliance 15 The appliance area must ...

Страница 8: ...ustomer This includes 1 Clocking the appliance to ensure the correct firing rate rate noted on label after burning appliance for 15 minutes Diagram 1 2 If required adjusting the primary air to ensure that the flame does not carbon First allow the unit to burn for 15 20 min to stabilize CAUTION Any alteration to the product that causes sooting or carboning that results in damage is not the responsi...

Страница 9: ...P 2 1 2 64mm 742mm 29 1 4 21 3 8 543mm 26 660mm 29 7 16 747mm 742mm 29 1 4 76mm 3 UNIT DIMENSIONS 4 SIDED FACEPLATE DIMENSIONS MANTEL DIMENSIONS 36 3 4 42 5 16 6 3 8 2 51mm 162mm 1074mm 933mm 47 9 16 21 1 2 29 9 16 52 1 8 35 1 2 9 8 1 8 3 5 5 1 8 1207mm 229mm 9 229mm 750mm 901mm 1324mm 545mm 127mm 206mm 130mm 76mm ...

Страница 10: ...s otherwise stated A major cause of chimney related fires is failure to maintain required clearances air space to combustible materials It is of the greatest importance that this fireplace and vent system be installed only in accordance with these instructions C F G Clearance Dimension Measured From A Front Floor Clearance min 0 Underside of Unit B Sidewall on one side 9 229mm Side Opening of Unit...

Страница 11: ...a non combustible board This drawing is to scale at 1 6 one inch 6 inches Mantel can be installed anywhere in shaded area or higher using the above scale Note Ensure the paint that is used on the mantel and the facing is heat resistant or the paint may discolour Combustible mantel leg clearances as per diagrams below Drywall Mantel Clearances 2 0 12 6 4 8 10 2 0 12 6 4 8 10 Top opening of Unit 12 ...

Страница 12: ...eplace INSTALLATION MANTEL LEG CLEARANCES Combustible mantel leg clearances from side of unit as per diagram Maximum 1 1 2 projection at 2 minimum clearance Top View 0 3 Allowable mantel leg projection 6 3 4 9 Side opening of Unit ...

Страница 13: ...other Non Combustible finish G Framing Width 35 889mm 35 889mm H Framing Height 31 3 4 806mm 31 3 4 806mm I Framing Rise from Floor 0 when not using a surround mantel 0 2 min w Modera Mantel 3 5 16 min w Verona Surround J Framing Depth Vertical Horizontal 23 1 4 578mm Vertical Rise 20 1 4 502mm Rigid 16 1 2 406mm Flex 22 3 4 578mm Vertical Rise 19 3 4 502mm Rigid 16 406mm Flex K Corner Wall Length...

Страница 14: ...tend onto the metal surface of the unit 5 Tile Finish Option 2 If applying a non combustible finishing material tile slate brick stone mantel surround etc the material can be installed directly onto the metal surface of the unit in the area shown below 29 7 16 747mm 21 3 8 542mm TILE STONE BRICK MANTEL SURROUND FINISH 1 There are 8 eight side nailing strips and one top nailing strip available on t...

Страница 15: ...rialshouldbuttupcleanly to the flanges around the firebox opening Rough edges may be visible from an angle To maintain a clean finished edge facing material edges may be finished with a J style trim or metal cornerbead both materials available at your local building or hardware store IMPORTANT Materials used must be NON COMBUSTIBLE 6 If applying a non combustible facing it may be installed over th...

Страница 16: ...nt Pro Selkirk Direct Temp Amerivent Direct Vent Metal Fab Sure Seal Security Secure Vent and ICC Excel Direct for Horizontal and Vertical Terminations see following Venting Sections for more details Note These flue pipes must not be connected to any other appliance The gas appliance and vent system must be vented directly to the outside of the building and never be attached to a chimney serving a...

Страница 17: ... above meter regulator assembly 36 90cm a J Clearance to service regulator vent outlet 36 90cm K Clearance to non mechanical air supply inlet to building or the combustion air inlet to any other appliance 12 30cm 9 23cm L Clearance to a mechanical air supply inlet 3 91cm above if within 10 3m horizontally 72 1 8m 36 90cm b M Clearance above paved sidewalk or a paved driveway located on public prop...

Страница 18: ...ermination Kit Part 946 513 includes all the parts needed to install the P33CE with a maximum run of 2 feet If install ing the P33E with a continuous vent length of more than 2 ft 6m to a maximum of 10 ft 3 0m use Kit 946 515 4 ft or 946 516 10 ft or see Rigid Pipe Venting Systems Section for alternate venting arrangements 1 6 7 8 dia flexible liner 2 ft length 2 4 dia flexible liner 2 ft length 3...

Страница 19: ...vent assembly by applying Mill Pac to the 4 100mm inner collar of the termination and slipping the 4 100mm liner over it at least 1 3 8 35mm Fasten with the 3 screws drillingpilotholeswillmakethiseasier Apply Mill Pac or high temperature silicone to the 6 7 8 175mm flex pipe and slip it over the 6 7 8 outer collar of the vent terminal at least 1 3 8 35mm and fasten with the 3 screws 4 Separate the...

Страница 20: ...lation Max Wall Vent Length Thickness inches Required inches 7 1 4 6 10 1 4 9 13 1 4 12 12 1 4 15 7 8 11 14 5 8 Adj Pipe 18 1 4 25 1 4 11 14 5 8 Adj Pipe Alternate Horizontal Termination Caps This product has been evaluated by Intertek for using a Rigid Pipe Adaptor in conjunction withDuraventDirect Vent SelkirkDirect Temp Ameri Vent Direct venting and Security Secure Vent systems Use of these sys...

Страница 21: ...lack N A N A N A 4DALB N A TC 4DLTB Adjustable Length 7 Galvanized N A N A 4D7A N A N A N A Adjustable Length 7 Black N A N A 4D7AB N A N A N A Extension Pipe 8 1 2 Galvanized 46DVA 08A N A N A N A N A N A Extension Pipe 8 1 2 Black 46DVA 08AB N A N A N A N A N A Adjustable Length 12 Galvanized N A N A 4D12A N A SV4LA12 N A Adjustable Length 12 Black N A N A 4D12A N A SV4LBA12 N A Extension Pipe 1...

Страница 22: ...6 N A N A N A N A N A TM 4ST36 Basic Horizontal Termination Kit A Disc 4DT HKA 4DHTK2 4DHTKA SV SHK N A Horizontal Termination Kit B 46DVA KHA Changed Components 4DT HKB 4DHTK1 4DHTKB SV HK N A Vertical Termination Kit Disc 4DT VKC 4DHTK 4DHTK SV FK N A FPI 946 506 P Vent Guard Optional for AstroCap 946 205 Vinyl Siding Shield for Riser Vent Terminal 510 994 Rigid Pipe Adaptor Must use with all ri...

Страница 23: ...ing Contemporary Faceplate unit must be raised 1 Note Must use optional rigid pipe adapter when using rigid vent systems Part 510 994 RIGID PIPE VENTING ARRANGEMENTS Vertical Terminations Propane Natural Gas The shaded area in the diagram shows all allowable combinations of straight vertical and offset to vertical terminations using one 90o elbow with rigid pipe vent systems for Propane and Natura...

Страница 24: ...diagramshowsallallowablecombinationsofstraight vertical and offset to vertical terminations with rigid pipe vent systems for Propane and Natural Gas Maximum two 45o elbows allowed Vent must be supported at offsets Firestops are required at each floor level and whenever passing through a wall Maintain clearances to combustibles When using Contemporary Faceplate unit must be raised 1 ...

Страница 25: ...art 510 994 when using rigid pipe vent systems Refer Rigid Pipe Venting Systems Section Maintain clearances to combustibles Horizontal vent must be supported every 3 feet Firestops are required at each floor level and whenever passing through a wall When using Contemporary Faceplate unit must be raised 1 A vent guard should be used whenever the terminationislowerthanthespecifiedminimum or as per l...

Страница 26: ...0o elbow Two 45o elbows Option H V H H1 H2 With these options maximum total pipe length is 30 feet with minimum of 11 feet total vertical and maximum 9 feet total horizontal P l e a s e n o t e minimum 1 foot between90o elbows is required A 1 Max 1 Min 3 Max B 2 Max 3 Min 5 Max C 3 Max 5 Min 6 Max D 4 Max 7 Min 7 Max E 5 Max 9 Min 8 Max F 6 Max 11 Min 9 Max One 90o elbow Two 45o elbows Option H V ...

Страница 27: ... Max 4 Min 5 Max C 4 Min 3 Max 6 Min 6 Max D 5 Min 4 Max 8 Min 7 Max E 6 Min 5 Max 10 Min 8 Max F 7 Min 6 Max 12 Min 9 Max One 90o elbow Two 45o elbows Option V H V V1 With these options maximum total pipe length is 30 feet with minimum of 6 feet total vertical and maximum 8 feet total horizontal Please note minimum 1 foot between 90o elbows is required A 1 Min 4 Max 2 Min B 2 Min 5 Max 3 Min C 3 ...

Страница 28: ...ws One 90o elbow Two 45o elbows With these options max total pipe length is 30 feet with min of 11 feet total vertical and max 7 feet total horizontal Please note min 1 foot between 90o elbows is required Option V H H1 V V1 A 2 Min 3 Max 4 Min B 3 Min 4 Max 6 Min C 4 Min 5 Max 7 Min D 5 Min 6 Max 8 Min E 6 Min 7 Max 9 Min F 7 Min 8 Max 10 Min Withtheseoptions max total pipelengthis30feetwithmin of...

Страница 29: ...ions Section for minimum and maximum heights Required Parts Part Description 946 529 Co linear DV Vertical Termination Cap 948 305 3 Flex 35 ft 946 563 Co Axial to Co Linear Adapter Kit whichcontainsthefollowing Co linear Flex Adapter Outer Pipe Inner Pipe Adapter 510 994 Rigid Pipe Adaptor 46DVA E45 45o Elbow Alternate Approved Caps 46dva VC Vertical Termination Cap 46dva VCH High Wind Cap 46dva ...

Страница 30: ...inear Flex System for both Residential Manufactured Homes into Masonry Fireplaces The shaded area in the diagrams show the allowable vertical terminations 8 2 4m Min 30 762mm 30 9 1m Max 30 Horizontal Distance Feet Vertical Height feet 2 51mm max When using Contemporary Faceplate unit must be raised 1 ...

Страница 31: ...ypes of sidings Diagram 2a Install the vent system according to the manufacturer s instructions included with the components 1 Set the unit in its desired location Check to determine if wall studs or roof rafters are in the way when the venting system is attached If this is the case you may want to adjust the location of the unit Rough in the gas preferably on the right side of the unit and the el...

Страница 32: ...th each approved venting system it is highlyrecommendedtoapply Mill Pac sealant supplied toeveryinnerpipeconnection Failure to do so may result in drafting or performance issues not covered under warranty Silicone red RTV is optional 8 Slide the appliance and vent assembly towards the wall carefully inserting the vent pipe into the vent cap assembly It is important that the vent pipeextendsintothe...

Страница 33: ... the hose and tighten the screw clockwise with a 1 8 flat screwdriver Note Screw should be snug but do not over tighten HIGH ELEVATION This unit is approved in Canada for altitude to 4500ft CAN CGA 2 17 M91 ForNaturalGas installations above 4500 ft follow current CAN CGA B149 1 886 S I T VALVE DESCRIPTION 1 Manual high low adjustment 2 Pilot adjustment 3 Outlet Pressure Tap 4 Inlet Pressure Tap 5 ...

Страница 34: ... and brick panels if installed 4 Remove the 2 screws holding the Burner Assembly to the firebox base Push the Burner Assembly to the left and lift out 6 Unscrew the pilot orifice with the Allen key and replace with the LPG pilot orifice in the kit and replace pilot cap 7 Remove burner orifice with a 1 2 wrench and discard Use another wrench to hold on to the elbow behind the orifice 8 Reinstall new bur...

Страница 35: ...theinstructionsbelowcarefully and refer to the diagrams If logs are broken do not use the unit until they are replaced Broken logs can interfere with the pilot operation Log Kit 431 930 contains the following pieces A 250 Rear Log B 254 Middle Cross Log C 253 Front Left Cross Log D 251 Rear Left Log E 252 Front Right Cross Log F Embers 902 156 G Vermiculite 902 179 H Rock Wool 902 153 I Platinum E...

Страница 36: ... 3 254 252 Cutout 9 Test fire to ensure proper light off make sure flame flows smoothly from one end of burner to the other If there is any flame hesitation check that area for any blockage of the burner ports Usethehooktopullthespringoutuntilyoucan put the hook into the slot on the bottom door bracket Repeatfor2ndspring Seediagram3 To remove the flush door reverse the above steps STANDARD FLUSH D...

Страница 37: ...he receiver with two screws and attach to the floor of the unit with a velcro pad 12 Reverse steps 5 and 4 13 Match the remote control to the receiver see remote control instructions 14 Reverse steps 2 and 1 15 Check to ensure there are no gas leaks 4 Remove DFC digital firebox control box from the floor of the unit 5 Disconnect wire harness ground wire and spark wire from DFC See attached wiring ...

Страница 38: ...nob if installed by removing 2 screws as shown below 8 Plug in receiver DC supply wire as shown below 5 Disconnect wire harness ground wire and spark wire from DFC DFC 4 Remove DFC digital firebox control box from the floor of the unit 1 Shut off the gas supply and disconnect all power to the unit 2 Remove the louvers bay door or faceplate if installed 3 Disconnect battery pack located on the floo...

Страница 39: ...also peel off paper on back side of wire clip and place wires conveniently in appliance 16 Bundle all wires together and clip with supplied wire clip as shown below 18 Match the remote control to the receiver see remote control instructions 19 Reverse steps 2 and 1 20 Check to ensure there are no gas leaks Heat shield 15 Install 4 AA batteries into the receiver 13 Plug the stepper motor into the m...

Страница 40: ...mbustible Material 3 1 2 x 36 Nailing Strip 1 2 back from unit face Combustible Material 2 Install four 4 wood screws two 2 on each side of the bracket into the wall studs as shown below Diagram 1 Materials flush w unit Diagram 2 Bracket screw locations on unit Diagram 3 Bracket screw locations Diagram 4 Line up faceplate and bracket Middle Rib on Faceplate Diagram 6 Final Install Diagram 5 Hang f...

Страница 41: ...ce Combustible Material 2 Install four 4 wood screws two 2 on each side of the bracket into the wall studs as shown below Diagram 1 Materials flush w unit Diagram 2 Bracket screw locations on unit Diagram 3 Bracket screw locations into stud Diagram 6 Final Install 5 Lift up mantel and line up the middle rib on backside of faceplate with middle indent on bracket This will centre the faceplate and a...

Страница 42: ...your warranty The remote control kit comes with a hand held transmitter a receiver and a wall mounting plate 1 Choose a convenient location on the wall to install the receiver and the receptacle box protectionfromextremeheatisveryimportant Run wires from the fireplace to that location 2 Connect the two wires to the gas valve See wiring diagram Optional wall switch GT GTM GTMF using wire 0 584 907 ...

Страница 43: ...t a later date Proflame System Configuration 886 GTMF Wire Diagram SureFire Switch Proflame System 886 ON OFF Stand Alone Illustrated Wire Diagram Surefire Switch IPI CPI Standard Main ON OFF Switch or Optional Wall Switch Battery Holder Pilot Ground Wire Chassis Ground EI Pilot Sense Electrode Spark Electrode DFC Wire Harness Assembly Proflame DFC Board 886 Proflame Valve Note 4 AA batteries must...

Страница 44: ...adaptor to the female end tagged DC Supply on wiring harness in unit 2 Locate FCM COM connector on the Remote wire harness see manual for location in unit 3 Plug in wire adaptor to FCM COM connector be careful not WR GDPDJH HQGV 7KLV RQO WV RQH ZD 3 Plug AC adaptor into 120V wall outlet or into 120V receptacle if LQVWDOOHG LQVLGH WKH JDV UHSODFH UHER 4 Neatly tuck any loose AC Power Adaptor wires ...

Страница 45: ...tional fan after unit is installed Note The bearings are lubricated for life Do not lubricate them Make sure you vacuum the fan area on a regular basis IMPORTANT These fans collect a lot of dust from within your home Ensure you maintain these fan motors on a regular basis by vacuuming out the fan blades and housing using a soft brush nozzle 7 Position the control plate assembly on the left hand si...

Страница 46: ...f desired The grounded duplex receptacle should be installed into the supplied receptacle box by a qualified electrician The neutral wider slot of the polarized receptacle should be at the top Unit must be grounded at all times Do not cut the ground terminal off under any circumstances 1 Shut the power off 2 Remove Flush door See instructions in this Manual 3 Remove inner panels See instructions i...

Страница 47: ...ove instructions Note The bearings are lubricated for life Do not lubricate them Make sure you vacuum the fan area on a regular basis IMPORTANT These fans collect a lot of dust from within your home Ensure you maintain these fan motors on a regular basis by vacuuming out the fan blades and housing using a soft brush nozzle 15 Position the control plate assembly on the left hand side of the firebox...

Страница 48: ... service or maintenance can cause injury or property damage Refer to the owner s information manual provided with this appliance For assistance or additional information consult a qualified installer service agency or gas supplier AVERTISSEMENT Quiconque ne respecte pas à la lettre les instructions dans la présente notice risquede déclencher un incendie ou une explosion entraînant des dommages des...

Страница 49: ...enclosed to prevent possible shock 3 Check to ensure there are no gas leaks 4 Make sure the glass in the door frame is properly positioned Never operate the appliance with the glass removed 5 Verify that the venting and cap are unobstructed 6 Ensure that the brick panels are installed 7 Verify log placement If the pilot cannot be seen when lighting the unit the logs have been incorrectly positione...

Страница 50: ...teriorportionsofthesystem being exposed to cold weather 4 Inspect joints to verify that no pipe sections or fittings have been disturbed and consequently loosened Also check mechanical supports such as Wall Straps or plumbers tape for rigidity LOG REPLACEMENT Theunitshouldneverbeusedwithbrokenlogs Turn off the gas valve and allow the unit to cool before opening door and carefully remove the logs T...

Страница 51: ...alers Do not use abrasive materials Do not clean the glass when hot In the event that you break your glass by impact purchase your replacement from an authorized Regency dealer only and follow our step by step instructions for replacement Flush Glass Replacement Remove the flush door front Remove the 4 glass clips from each corner Slide in the new replacement glass Push the 4 glass clips back onto...

Страница 52: ...d then lift out the burner grate assembly 4 Remove the rear log stand by removing the 2 screws INSTALLING VALVE 1 Install new valve assembly 2 Reverse steps 7 1 Diagram 5 Lift out Valve Tray Assembly EV1 EV2 Ground 8 Remove valve tray assembly 7 Remove the 12 screws securing the valve tray assembly in place Diagram 4 and then lift the entire assembly out Diagram 4 Valve Tray Assembly Diagram 2 Dia...

Страница 53: ...37 515 Valve Assembly 4 432 917 Fan Assembly 5 437 024 Screen glass guard 6 433 538 Glass Door Assembly 7 Clean Front Assembly 8 Firebox Assembly Not a replacement part Part Description Orifice 44 NG 904 163 Orifice 54 LP 911 004 886 Proflame Valve 919 125 Manual 1 3 5 6 4 2 7 8 ...

Страница 54: ...ropane 57 911 004 Valve SIT NG 911 005 Valve SIT LP 58 Valve Bracket 59 Firebox Base 60 Valve Tray 66 911 006 Pilot Assy 886 S I T NG 911 007 Pilot Assy 886 S I T LP 904 568 Orifice 44 Natural Gas 904 163 Orifice 54 Propane 936 170 Orifice Gasket 67 Pilot Holder 68 W840470 Pilot Assembly Gasket 79 433 525 Burner Assy NG LP 82 433 024 Burner Grate Assembly NG LP 83 Rear Log Support Bracket NG LP 85...

Страница 55: ...ts will be repaired or replaced at FPI s option through an accredited distributor or agent that the defective part be returned to the distributor or agent Transportation Prepaid if requested Porcelain Enamel Absolute perfectionisneither guaranteednor commercially possible Any chips must be reported and inspected by an authorized dealer within thre installation Reported damage after this time will ...

Страница 56: ..._____________________________________________ Serial No __________________________________________________________ Register your Regency warranty online www regency fire com Reasons to register your product online today View and modify a list of all your registered products Request automatic email notification of new product updates Stay informed about the current promotions events and spe cial of...